ID
38406
Description
With permission from the DZHK administrative office. http://dzhk.de The DZHK (Deutsches Zentrum für Herz-Kreislauf-Forschung e.V.; German Center for Cardiovascular Research) is a joint cooperation of twenty-eight institutions in seven locations throughout Germany to develop a common research strategy. They developed a data catalogue with metadata and data as well as information about available biological materials from all their studies. For more information on the data catalogue and access to actual data and biosamples please visit https://dzhk.de/en/resources/data-manual/ . This version contains the metadata part only. The module Spiroergometry is used to document spiroergometry examinations. The cardiopulmonary exercise test analyses the reactions and the interplay of the heart, circulation, breathing and metabolism during gradually increasing exercise, both in terms of qualitative and quantitative measures. The cardiopulmonary exercise test should be the last test performed on the examination day. This form uses the Borg scales of dyspnoea (Borg, G.A., Psychophysical bases of perceived exertion. Medicine and science in sports and exercise, 1982. 14(5): p. 377-81) and exertion (Borg, G., Anstrengungsempfinden und körperliche Aktivität. Dtsch Arztebl International, 2004. 101(15): p. 1016-). The documentation is to be performed according to the DZHK's SOPs, which can be accessed at https://dzhk.de/en/resources/sops/ (or https://dzhk.de/ressourcen/sops/ for the German language versions). The SOPs for this form are "Cardiopulmonary exercise test (spiroergometry)" (version 1.1, effective as of 01/07/2017), and "Spiroergometrie " (version 1.1, effective as of 01/07/2015), for the English and German versions, respectively. Inclusion Criteria: All subjects who are capable of cycling on an ergometer or of doing exercise on a treadmill and to whom no exclusion criteria apply can take part. Special inclusion criteria are stipulated in the study protocol of the respective study/register. Exclusion criteria: Absolute contraindications: • Acute relevant disease, e.g. recent myocardial infarction, systemic infections, thromboses or embolisms, acute exacerbation of a respiratory disease. • Severe cardiac arrhythmia or blocks (second- or third-degree AV block). • Insufficiently controlled arterial hypertension (RRsyst >170 mmHg, and/or RRdiast >110 mmHg). • Known symptomatic or severe aortic stenosis. Relative contraindications: • Tachycardia at rest (>120 bpm). • Poorly managed epilepsy with the risk of provoking a seizure through exercise. • Symptomatic electrolyte imbalance or metabolic imbalance. • Symptomatic impaired cerebral circulation. If necessary, specific criteria of the respective studies or registers have to be observed.
Link
Keywords
Versions (2)
- 10/16/19 10/16/19 -
- 10/16/19 10/16/19 -
Copyright Holder
DZHK
Uploaded on
October 16, 2019
DOI
To request one please log in.
License
Creative Commons BY-NC 3.0
Model comments :
You can comment on the data model here. Via the speech bubbles at the itemgroups and items you can add comments to those specificially.
Itemgroup comments for :
Item comments for :
In order to download data models you must be logged in. Please log in or register for free.
DZHK Data Catalogue
Spiroergometry
- StudyEvent: ODM
Description
Examination
Alias
- UMLS CUI-1
- C2959886
Description
Pacemaker
Data type
text
Alias
- UMLS CUI [1]
- C0030163
Description
Heart rhythm
Data type
text
Alias
- UMLS CUI [1]
- C0232187
Description
Beta blockers
Data type
text
Alias
- UMLS CUI [1]
- C0001645
Description
Timestamp with minutes and seconds
Data type
time
Alias
- UMLS CUI [1,1]
- C0449238
- UMLS CUI [1,2]
- C2959886
Description
Treadmill See SOPs for protocols.
Data type
text
Alias
- UMLS CUI [1,1]
- C2959886
- UMLS CUI [1,2]
- C0184069
- UMLS CUI [1,3]
- C0332307
Description
Bicycle. See SOPs for protocols.
Data type
text
Alias
- UMLS CUI [1,1]
- C0005375
- UMLS CUI [1,2]
- C2959886
- UMLS CUI [1,3]
- C0332307
Description
Objective stopping criteria: ST depression (> 0.2 mV) or elevation. Progressive atrial or ventricular arrhythmia or block images Newly occurring atrial fibrillation Drop in heart rate during exercise Lack of increase or drop in RR across 2 exercise levels Drop in O2 uptake (or oxygen pulse) in spite of increasing the load. Subjective stopping criteria: Maximal fatigue (e.g. of the legs) Thoracic pain (e.g. symptoms of angina), severe dizziness Excessive dyspnoea Subject signals to examiner to end the examination.
Data type
text
Alias
- UMLS CUI [1,1]
- C0457454
- UMLS CUI [1,2]
- C0566251
- UMLS CUI [1,3]
- C2959886
Description
Heart rate at rest
Data type
integer
Measurement units
- /min
Alias
- UMLS CUI [1,1]
- C0018810
- UMLS CUI [1,2]
- C0443144
Description
Maximum heart rate during Cardiopulmonary Exercise Test
Data type
integer
Measurement units
- /min
Alias
- UMLS CUI [1,1]
- C0018810
- UMLS CUI [1,2]
- C0806909
- UMLS CUI [1,3]
- C0347984
- UMLS CUI [1,4]
- C2959886
Description
Heart Rate after Cardiopulmonary Exercise Test
Data type
integer
Measurement units
- /min
Alias
- UMLS CUI [1,1]
- C0018810
- UMLS CUI [1,2]
- C0687676
- UMLS CUI [1,3]
- C2959886
Description
Systolic BP (at rest)
Data type
integer
Measurement units
- mmHg
Alias
- UMLS CUI [1]
- C2039694
Description
Diastolic BP (at rest)
Data type
integer
Measurement units
- mmHg
Alias
- UMLS CUI [1]
- C2183311
Description
Systolic BP during Cardiopulmonary Exercise Test
Data type
integer
Measurement units
- mmHg
Alias
- UMLS CUI [1,1]
- C0871470
- UMLS CUI [1,2]
- C0347984
- UMLS CUI [1,3]
- C2959886
Description
Diastolic BP during Cardiopulmonary Exercise Test
Data type
integer
Measurement units
- mmHg
Alias
- UMLS CUI [1,1]
- C0347984
- UMLS CUI [1,2]
- C2959886
- UMLS CUI [1,3]
- C0428883
Description
Maximum power in Cardiopulmonary Exercise Test
Data type
integer
Measurement units
- Watt
Alias
- UMLS CUI [1,1]
- C0806909
- UMLS CUI [1,2]
- C3854080
- UMLS CUI [1,3]
- C2959886
Description
VE/VCO2 (at rest)
Data type
float
Alias
- UMLS CUI [1,1]
- C1301655
- UMLS CUI [1,2]
- C0429247
- UMLS CUI [1,3]
- C0443144
Description
VE/VCO2 during Cardiopulmonary Exercise Test
Data type
float
Alias
- UMLS CUI [1,1]
- C1301655
- UMLS CUI [1,2]
- C0429247
- UMLS CUI [1,3]
- C0347984
- UMLS CUI [1,4]
- C2959886
Description
averaged across 3 minutes of resting
Data type
integer
Measurement units
- mmHg
Alias
- UMLS CUI [1,1]
- C0428664
- UMLS CUI [1,2]
- C0443144
Description
End-tidal CO2 partial pressure during Cardiopulmonary Exercise Test
Data type
integer
Measurement units
- mmHg
Alias
- UMLS CUI [1,1]
- C0428664
- UMLS CUI [1,2]
- C0347984
- UMLS CUI [1,3]
- C2959886
Description
Defined as the slope of the straight line in field 5 (VE to VCO₂) value one minute after starting the exercise until VT2 (RCP). Respiratory compensation point (RCP or VT2): Defined as the point at which there is a disproportionate increase from VE to VCO₂, which is read as an increase in EQCO2 in field 6.
Data type
integer
Alias
- UMLS CUI [1,1]
- C1301655
- UMLS CUI [1,2]
- C0429247
- UMLS CUI [1,3]
- C0807955
Description
VO2 (at rest)
Data type
float
Alias
- UMLS CUI [1,1]
- C0030055
- UMLS CUI [1,2]
- C0443144
Description
VO2 (at rest) Unit
Data type
text
Alias
- UMLS CUI [1,1]
- C0030055
- UMLS CUI [1,2]
- C0443144
- UMLS CUI [1,3]
- C1519795
Description
Highest VO2value achieved during exercise. A reliable statement about VO₂ peak can only be made if an RER of >1.05 was achieved during exercise.
Data type
integer
Measurement units
- ml/min
Alias
- UMLS CUI [1,1]
- C1305742
- UMLS CUI [1,2]
- C0444505
Description
See SOP for reference values
Data type
float
Alias
- UMLS CUI [1,1]
- C0030055
- UMLS CUI [1,2]
- C0086715
Description
VO2 Norm Unit
Data type
text
Alias
- UMLS CUI [1,1]
- C0030055
- UMLS CUI [1,2]
- C0086715
- UMLS CUI [1,3]
- C1519795
Description
Anaerobic threshold determined by ventilation (AT or VT1): Defines the first increase in lactate and marks the start of the aerobic/anaerobic threshold. This value can be measured by detecting the first change in the gradient in field 5 of the Wassermann graphs (VCO₂/VE) or the first increase in the oxygen equivalent in field 6 of the Wassermann graphs (EQO₂).
Data type
float
Alias
- UMLS CUI [1,1]
- C0030055
- UMLS CUI [1,2]
- C0002749
Description
VO2 at aerobic/anaerobic threshold Unit
Data type
text
Alias
- UMLS CUI [1,1]
- C0030055
- UMLS CUI [1,2]
- C0002749
- UMLS CUI [1,3]
- C1519795
Description
Maximum minute volume during exhalation
Data type
integer
Measurement units
- l/min
Alias
- UMLS CUI [1,1]
- C1959925
- UMLS CUI [1,2]
- C0806909
Description
Respiratory rate (at rest)
Data type
integer
Measurement units
- /min
Alias
- UMLS CUI [1,1]
- C0231832
- UMLS CUI [1,2]
- C0443144
Description
Respiratory rate during Cardiopulmonary Exercise Test
Data type
integer
Measurement units
- /min
Alias
- UMLS CUI [1,1]
- C0231832
- UMLS CUI [1,2]
- C0347984
- UMLS CUI [1,3]
- C2959886
Description
Respiratory rate maximum
Data type
integer
Measurement units
- /min
Alias
- UMLS CUI [1,1]
- C0231832
- UMLS CUI [1,2]
- C0806909
Description
VT (at rest)
Data type
float
Measurement units
- ml
Alias
- UMLS CUI [1,1]
- C0040210
- UMLS CUI [1,2]
- C0443144
Description
VT during Cardiopulmonary Exercise Test
Data type
float
Measurement units
- ml
Alias
- UMLS CUI [1,1]
- C0040210
- UMLS CUI [1,2]
- C0347984
- UMLS CUI [1,3]
- C2959886
Description
VD/VT (at rest)
Data type
float
Measurement units
- %
Alias
- UMLS CUI [1,1]
- C0429747
- UMLS CUI [1,2]
- C0443144
Description
VD/VT during Cardiopulmonary Exercise Test
Data type
float
Measurement units
- %
Alias
- UMLS CUI [1,1]
- C0429747
- UMLS CUI [1,2]
- C0347984
- UMLS CUI [1,3]
- C2959886
Description
Saturation sO2 (at rest)
Data type
integer
Measurement units
- %
Alias
- UMLS CUI [1,1]
- C0523807
- UMLS CUI [1,2]
- C0443144
Description
Saturation sO2 during Cardiopulmonary Exercise Test
Data type
integer
Measurement units
- %
Alias
- UMLS CUI [1,1]
- C0523807
- UMLS CUI [1,2]
- C0347984
- UMLS CUI [1,3]
- C2959886
Description
Respiratory quotient (RQ) at rest
Data type
float
Alias
- UMLS CUI [1,1]
- C0199508
- UMLS CUI [1,2]
- C0443144
Description
Respiratory quotient (RQ) during Cardiopulmonary Exercise Test
Data type
float
Alias
- UMLS CUI [1,1]
- C0199508
- UMLS CUI [1,2]
- C0347984
- UMLS CUI [1,3]
- C2959886
Description
Respiratory quotient (RQ) after Cardiopulmonary Exercise Test
Data type
float
Alias
- UMLS CUI [1,1]
- C0199508
- UMLS CUI [1,2]
- C0687676
- UMLS CUI [1,3]
- C2959886
Description
It is recommended to preferably use the 6/20 scale for DZHK studies. The variant of the BORG scale to be used has to be stipulated in the study protocol of the respective studies.
Data type
text
Alias
- UMLS CUI [1,1]
- C0332307
- UMLS CUI [1,2]
- C0449399
Description
Borg perceived exertion scale
Data type
text
Alias
- UMLS CUI [1]
- C4055363
Description
Borg dyspnoea scale
Data type
text
Alias
- UMLS CUI [1,1]
- C0449399
- UMLS CUI [1,2]
- C0013404
Similar models
Spiroergometry
- StudyEvent: ODM
C2959886 (UMLS CUI-2)
C2959886 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,2])
C0184069 (UMLS CUI [1,2])
C0332307 (UMLS CUI [1,3])
C2959886 (UMLS CUI [1,2])
C0332307 (UMLS CUI [1,3])
C0566251 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
C0443144 (UMLS CUI [1,2])
C0806909 (UMLS CUI [1,2])
C0347984 (UMLS CUI [1,3])
C2959886 (UMLS CUI [1,4])
C0687676 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
C2959886 (UMLS CUI [1,2])
C0428883 (UMLS CUI [1,3])
C3854080 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
C0429247 (UMLS CUI [1,2])
C0443144 (UMLS CUI [1,3])
C0429247 (UMLS CUI [1,2])
C0347984 (UMLS CUI [1,3])
C2959886 (UMLS CUI [1,4])
C0443144 (UMLS CUI [1,2])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
C0429247 (UMLS CUI [1,2])
C0807955 (UMLS CUI [1,3])
C0443144 (UMLS CUI [1,2])
C0443144 (UMLS CUI [1,2])
C1519795 (UMLS CUI [1,3])
C0444505 (UMLS CUI [1,2])
C0086715 (UMLS CUI [1,2])
C0086715 (UMLS CUI [1,2])
C1519795 (UMLS CUI [1,3])
C0002749 (UMLS CUI [1,2])
C0002749 (UMLS CUI [1,2])
C1519795 (UMLS CUI [1,3])
C0806909 (UMLS CUI [1,2])
C0443144 (UMLS CUI [1,2])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
C0806909 (UMLS CUI [1,2])
C0443144 (UMLS CUI [1,2])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
C0443144 (UMLS CUI [1,2])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
C0443144 (UMLS CUI [1,2])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
C0443144 (UMLS CUI [1,2])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
C0687676 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
C0013404 (UMLS CUI [1,2])