ID

38405

Descripción

With permission from the DZHK administrative office. http://dzhk.de The DZHK (Deutsches Zentrum für Herz-Kreislauf-Forschung e.V.; German Center for Cardiovascular Research) is a joint cooperation of twenty-eight institutions in seven locations throughout Germany to develop a common research strategy. They developed a data catalogue with metadata and data as well as information about available biological materials from all their studies. For more information on the data catalogue and access to actual data and biosamples please visit https://dzhk.de/en/resources/data-manual/ . This version contains the metadata part only. The module Spiroergometry is used to document spiroergometry examinations. The cardiopulmonary exercise test analyses the reactions and the interplay of the heart, circulation, breathing and metabolism during gradually increasing exercise, both in terms of qualitative and quantitative measures. The cardiopulmonary exercise test should be the last test performed on the examination day. This form uses the Borg scales of dyspnoea (Borg, G.A., Psychophysical bases of perceived exertion. Medicine and science in sports and exercise, 1982. 14(5): p. 377-81) and exertion (Borg, G., Anstrengungsempfinden und körperliche Aktivität. Dtsch Arztebl International, 2004. 101(15): p. 1016-). The documentation is to be performed according to the DZHK's SOPs, which can be accessed at https://dzhk.de/en/resources/sops/ (or https://dzhk.de/ressourcen/sops/ for the German language versions). The SOPs for this form are "Cardiopulmonary exercise test (spiroergometry)" (version 1.1, effective as of 01/07/2017), and "Spiroergometrie " (version 1.1, effective as of 01/07/2015), for the English and German versions, respectively. Inclusion Criteria: All subjects who are capable of cycling on an ergometer or of doing exercise on a treadmill and to whom no exclusion criteria apply can take part. Special inclusion criteria are stipulated in the study protocol of the respective study/register. Exclusion criteria: Absolute contraindications: • Acute relevant disease, e.g. recent myocardial infarction, systemic infections, thromboses or embolisms, acute exacerbation of a respiratory disease. • Severe cardiac arrhythmia or blocks (second- or third-degree AV block). • Insufficiently controlled arterial hypertension (RRsyst >170 mmHg, and/or RRdiast >110 mmHg). • Known symptomatic or severe aortic stenosis. Relative contraindications: • Tachycardia at rest (>120 bpm). • Poorly managed epilepsy with the risk of provoking a seizure through exercise. • Symptomatic electrolyte imbalance or metabolic imbalance. • Symptomatic impaired cerebral circulation. If necessary, specific criteria of the respective studies or registers have to be observed.

Link

http://dzhk.de

Palabras clave

  1. 16/10/19 16/10/19 -
  2. 16/10/19 16/10/19 -
Titular de derechos de autor

DZHK

Subido en

16 de octubre de 2019

DOI

Para solicitar uno, por favor iniciar sesión.

Licencia

Creative Commons BY-NC 3.0

Comentarios del modelo :

Puede comentar sobre el modelo de datos aquí. A través de las burbujas de diálogo en los grupos de elementos y elementos, puede agregar comentarios específicos.

Comentarios de grupo de elementos para :

Comentarios del elemento para :

Para descargar modelos de datos, debe haber iniciado sesión. Por favor iniciar sesión o Registrate gratis.

DZHK Data Catalogue

Spiroergometry

  1. StudyEvent: ODM
    1. Spiroergometry
Angaben zur Untersuchung
Descripción

Angaben zur Untersuchung

Alias
UMLS CUI-1
C1522508
UMLS CUI-2
C2959886
Wurde die Spiroergometrie durchgeführt
Descripción

Cardiopulmonary exercise testing performed?

Tipo de datos

text

Alias
UMLS CUI [1,1]
C0884358
UMLS CUI [1,2]
C2959886
Datum der Untersuchung
Descripción

Cardiopulmonary exercise test date

Tipo de datos

date

Alias
UMLS CUI [1,1]
C0011008
UMLS CUI [1,2]
C2959886
Qualitätslevel
Descripción

Cardiopulmonary Exercise Test quality

Tipo de datos

integer

Alias
UMLS CUI [1,1]
C0332306
UMLS CUI [1,2]
C2959886
Untersuchung
Descripción

Untersuchung

Alias
UMLS CUI-1
C2959886
Herzschrittmacher
Descripción

Pacemaker

Tipo de datos

text

Alias
UMLS CUI [1]
C0030163
Herzrhythmus
Descripción

Heart rhythm

Tipo de datos

text

Alias
UMLS CUI [1]
C0232187
Einnahme von Betablockern
Descripción

Beta blockers

Tipo de datos

text

Alias
UMLS CUI [1]
C0001645
Belastungsdauer
Descripción

Duration of exercise test

Tipo de datos

time

Alias
UMLS CUI [1,1]
C0449238
UMLS CUI [1,2]
C2959886
Belastungsart: Laufband
Descripción

Laufband. Protokolle s. SOPs.

Tipo de datos

text

Alias
UMLS CUI [1,1]
C2959886
UMLS CUI [1,2]
C0184069
UMLS CUI [1,3]
C0332307
Belastungsart: Fahrrad
Descripción

Fahrrad. Protokolle s. SOPs.

Tipo de datos

text

Alias
UMLS CUI [1,1]
C0005375
UMLS CUI [1,2]
C2959886
UMLS CUI [1,3]
C0332307
Abbruchgrund
Descripción

Objektive Abbruchkriterien sind: ST-Strecken-Senkungen (> 0,2 mV) oder Hebungen. Progrediente atriale oder ventrikuläre Arrhythmien oder Blockbilder neu aufgetretenes Vorhofflimmern Frequenzabfall unter Belastung Fehlender RR-Anstieg bzw. RR-Abfall über 2 Belastungsstufen Abfall der 02 Aufnahme (bzw. Sauerstoffpulses) trotz Steigerung der Last. Subjektive Abbruchkriterien sind: maximale Erschöpfung (z.B. der Beine) Thoraxschmerzen (z.B. AP-Symptomatik), starker Schwindel Übermäßige Dyspnoe Proband zeigt Wunsch nach Abbruch an.

Tipo de datos

text

Alias
UMLS CUI [1,1]
C0457454
UMLS CUI [1,2]
C0566251
UMLS CUI [1,3]
C2959886
HF (Ruhe)
Descripción

Heart rate at rest

Tipo de datos

integer

Unidades de medida
  • /min
Alias
UMLS CUI [1,1]
C0018810
UMLS CUI [1,2]
C0443144
/min
HFmax (Belastung)
Descripción

Maximum heart rate during Cardiopulmonary Exercise Test

Tipo de datos

integer

Unidades de medida
  • /min
Alias
UMLS CUI [1,1]
C0018810
UMLS CUI [1,2]
C0806909
UMLS CUI [1,3]
C0347984
UMLS CUI [1,4]
C2959886
/min
HF (1min nach Belastung)
Descripción

Heart Rate after Cardiopulmonary Exercise Test

Tipo de datos

integer

Unidades de medida
  • /min
Alias
UMLS CUI [1,1]
C0018810
UMLS CUI [1,2]
C0687676
UMLS CUI [1,3]
C2959886
/min
RRsys (Ruhe)
Descripción

Systolic BP (at rest)

Tipo de datos

integer

Unidades de medida
  • mmHg
Alias
UMLS CUI [1]
C2039694
mmHg
RRdia (Ruhe)
Descripción

Diastolic BP (at rest)

Tipo de datos

integer

Unidades de medida
  • mmHg
Alias
UMLS CUI [1]
C2183311
mmHg
RRsys (Belastung)
Descripción

Systolic BP during Cardiopulmonary Exercise Test

Tipo de datos

integer

Unidades de medida
  • mmHg
Alias
UMLS CUI [1,1]
C0871470
UMLS CUI [1,2]
C0347984
UMLS CUI [1,3]
C2959886
mmHg
RRdia (Belastung)
Descripción

Diastolic BP during Cardiopulmonary Exercise Test

Tipo de datos

integer

Unidades de medida
  • mmHg
Alias
UMLS CUI [1,1]
C0347984
UMLS CUI [1,2]
C2959886
UMLS CUI [1,3]
C0428883
mmHg
Watt (max)
Descripción

Maximum power in Cardiopulmonary Exercise Test

Tipo de datos

integer

Unidades de medida
  • Watt
Alias
UMLS CUI [1,1]
C0806909
UMLS CUI [1,2]
C3854080
UMLS CUI [1,3]
C2959886
Watt
VE/VCO2 (Ruhe)
Descripción

VE/VCO2 (at rest)

Tipo de datos

float

Alias
UMLS CUI [1,1]
C1301655
UMLS CUI [1,2]
C0429247
UMLS CUI [1,3]
C0443144
VE/VCO2 (Belastung)
Descripción

VE/VCO2 during Cardiopulmonary Exercise Test

Tipo de datos

float

Alias
UMLS CUI [1,1]
C1301655
UMLS CUI [1,2]
C0429247
UMLS CUI [1,3]
C0347984
UMLS CUI [1,4]
C2959886
PET CO2 (Ruhe)
Descripción

End-tidal CO2 partial pressure (at rest)

Tipo de datos

integer

Unidades de medida
  • mmHg
Alias
UMLS CUI [1,1]
C0428664
UMLS CUI [1,2]
C0443144
mmHg
PET CO2 (Belastung)
Descripción

End-tidal CO2 partial pressure during Cardiopulmonary Exercise Test

Tipo de datos

integer

Unidades de medida
  • mmHg
Alias
UMLS CUI [1,1]
C0428664
UMLS CUI [1,2]
C0347984
UMLS CUI [1,3]
C2959886
mmHg
VE/VCO2-slope
Descripción

Definiert als Steigung der Geraden in Feld 5 (VE zu VCO2) Wert eine Minute nach Belastungsbeginn bis VT2(RCP). Respiratorischer Kompensationspunkt (RCP oder VT2): Definiert als Punkt, an dem es zu einem überproportionalen Anstieg von VE zu VCO₂, abzulesen als Anstieg des EQCO2 in Feld 6.

Tipo de datos

integer

Alias
UMLS CUI [1,1]
C1301655
UMLS CUI [1,2]
C0429247
UMLS CUI [1,3]
C0807955
VO2 (Ruhe)
Descripción

VO2 (at rest)

Tipo de datos

float

Alias
UMLS CUI [1,1]
C0030055
UMLS CUI [1,2]
C0443144
VO2 (at rest)
Descripción

VO2 (at rest) Unit

Tipo de datos

text

Alias
UMLS CUI [1,1]
C0030055
UMLS CUI [1,2]
C0443144
UMLS CUI [1,3]
C1519795
VO2 peak
Descripción

Höchster VO2-Wert der unter Belastung erreicht wird. Eine verlässliche Aussage zu VO2 peak ist nur möglich, wenn ein RER unter Belastung >1,05 erreicht wurde.

Tipo de datos

integer

Unidades de medida
  • ml/min
Alias
UMLS CUI [1,1]
C1305742
UMLS CUI [1,2]
C0444505
ml/min
VO2 Norm
Descripción

VO2 Norm

Tipo de datos

float

Alias
UMLS CUI [1,1]
C0030055
UMLS CUI [1,2]
C0086715
VO2 Norm
Descripción

VO2 Norm Unit

Tipo de datos

text

Alias
UMLS CUI [1,1]
C0030055
UMLS CUI [1,2]
C0086715
UMLS CUI [1,3]
C1519795
VO2 AT
Descripción

Ventilatorisch bestimmte anaerobe Schwelle (AT oder VT1): Definiert den ersten Laktatanstieg und repräsentiert den Beginn des aerob-anaeroben Übergangs. Sie kann ermittelt werden über die erste Steigungsänderung in Feld 5 der Wassermanngraphiken (VCO₂/VE) oder über den ersten Anstieg des Sauerstoffäquivalents in Feld 6 der Wassermanngraphiken (EQO₂).

Tipo de datos

float

Alias
UMLS CUI [1,1]
C0030055
UMLS CUI [1,2]
C0002749
VO2 AT
Descripción

VO2 at aerobic/anaerobic threshold Unit

Tipo de datos

text

Alias
UMLS CUI [1,1]
C0030055
UMLS CUI [1,2]
C0002749
UMLS CUI [1,3]
C1519795
VE max
Descripción

Maximum minute volume during exhalation

Tipo de datos

integer

Unidades de medida
  • l/min
Alias
UMLS CUI [1,1]
C1959925
UMLS CUI [1,2]
C0806909
l/min
AF (Ruhe)
Descripción

Respiratory rate (at rest)

Tipo de datos

integer

Unidades de medida
  • /min
Alias
UMLS CUI [1,1]
C0231832
UMLS CUI [1,2]
C0443144
/min
AF (Belastung)
Descripción

Respiratory rate during Cardiopulmonary Exercise Test

Tipo de datos

integer

Unidades de medida
  • /min
Alias
UMLS CUI [1,1]
C0231832
UMLS CUI [1,2]
C0347984
UMLS CUI [1,3]
C2959886
/min
AF max
Descripción

Respiratory rate maximum

Tipo de datos

integer

Unidades de medida
  • /min
Alias
UMLS CUI [1,1]
C0231832
UMLS CUI [1,2]
C0806909
/min
VT (Ruhe)
Descripción

VT (at rest)

Tipo de datos

float

Unidades de medida
  • ml
Alias
UMLS CUI [1,1]
C0040210
UMLS CUI [1,2]
C0443144
ml
VT (Belastung)
Descripción

VT during Cardiopulmonary Exercise Test

Tipo de datos

float

Unidades de medida
  • ml
Alias
UMLS CUI [1,1]
C0040210
UMLS CUI [1,2]
C0347984
UMLS CUI [1,3]
C2959886
ml
VD/VT (Ruhe)
Descripción

VD/VT (at rest)

Tipo de datos

float

Unidades de medida
  • %
Alias
UMLS CUI [1,1]
C0429747
UMLS CUI [1,2]
C0443144
%
VD/VT (Belastung)
Descripción

VD/VT during Cardiopulmonary Exercise Test

Tipo de datos

float

Unidades de medida
  • %
Alias
UMLS CUI [1,1]
C0429747
UMLS CUI [1,2]
C0347984
UMLS CUI [1,3]
C2959886
%
Sättigung sO2 (Ruhe)
Descripción

Saturation sO2 (at rest)

Tipo de datos

integer

Unidades de medida
  • %
Alias
UMLS CUI [1,1]
C0523807
UMLS CUI [1,2]
C0443144
%
Sättigung sO2 (Belastung)
Descripción

Saturation sO2 during Cardiopulmonary Exercise Test

Tipo de datos

integer

Unidades de medida
  • %
Alias
UMLS CUI [1,1]
C0523807
UMLS CUI [1,2]
C0347984
UMLS CUI [1,3]
C2959886
%
Respiratorischer Quotient (RQ) Ruhe
Descripción

Respiratory quotient (RQ) at rest

Tipo de datos

float

Alias
UMLS CUI [1,1]
C0199508
UMLS CUI [1,2]
C0443144
Respiratorischer Quotient (RQ) Belastung
Descripción

Respiratory quotient (RQ) during Cardiopulmonary Exercise Test

Tipo de datos

float

Alias
UMLS CUI [1,1]
C0199508
UMLS CUI [1,2]
C0347984
UMLS CUI [1,3]
C2959886
Respiratorischer Quotient nach Belastungsende (RQ maxpost)
Descripción

Respiratory quotient (RQ) after Cardiopulmonary Exercise Test

Tipo de datos

float

Alias
UMLS CUI [1,1]
C0199508
UMLS CUI [1,2]
C0687676
UMLS CUI [1,3]
C2959886
Verwendete BORG-Skala
Descripción

Used BORG scale

Tipo de datos

text

Alias
UMLS CUI [1,1]
C0332307
UMLS CUI [1,2]
C0449399
Borg-Antrengungsskala
Descripción

Borg perceived exertion scale

Tipo de datos

text

Alias
UMLS CUI [1]
C4055363
Borg-Atemnot-Skala
Descripción

Borg dyspnoea scale

Tipo de datos

text

Alias
UMLS CUI [1,1]
C0449399
UMLS CUI [1,2]
C0013404

Similar models

Spiroergometry

  1. StudyEvent: ODM
    1. Spiroergometry
Name
Tipo
Description | Question | Decode (Coded Value)
Tipo de datos
Alias
Item Group
Angaben zur Untersuchung
C1522508 (UMLS CUI-1)
C2959886 (UMLS CUI-2)
Item
Wurde die Spiroergometrie durchgeführt
text
C0884358 (UMLS CUI [1,1])
C2959886 (UMLS CUI [1,2])
Code List
Wurde die Spiroergometrie durchgeführt
CL Item
ja (yes)
CL Item
nein (no)
CL Item
unbekannt (unknown)
CL Item
nicht erhoben (not assessed)
Cardiopulmonary exercise test date
Item
Datum der Untersuchung
date
C0011008 (UMLS CUI [1,1])
C2959886 (UMLS CUI [1,2])
Item
Qualitätslevel
integer
C0332306 (UMLS CUI [1,1])
C2959886 (UMLS CUI [1,2])
Code List
Qualitätslevel
CL Item
Stufe 1: Durchführung der Untersuchung unter Berücksichtigung der Leitlinien der Fachgesellschaften. (1)
CL Item
Stufe 2: Durchführung der Untersuchung nach den Vorgaben des DZHK-SOP. Hierin werden Mindestanforderungen für die Qualität der Durchführung und der Untersucher definiert. (2)
CL Item
Stufe 3: Durchführung der Untersuchung nach den Vorgaben des DZHK-SOP und Zertifizierung der Untersucher: Bestimmung von Intra- und Interobservervariabilität (Standard epidemiologischer Studien). (3)
Item Group
Untersuchung
C2959886 (UMLS CUI-1)
Item
Herzschrittmacher
text
C0030163 (UMLS CUI [1])
Code List
Herzschrittmacher
CL Item
ja (yes)
CL Item
nein (no)
CL Item
unbekannt (unknown)
CL Item
nicht erhoben (not assessed)
Item
Herzrhythmus
text
C0232187 (UMLS CUI [1])
Code List
Herzrhythmus
CL Item
Sinusrhythmus (sinus rhythm)
CL Item
Vorhofflimmern (atrial fibrillation)
CL Item
Schrittmacherrhythmus (pacemaker rhythm)
CL Item
unbekannt (unknown)
CL Item
nicht erhoben (not assessed)
Item
Einnahme von Betablockern
text
C0001645 (UMLS CUI [1])
Code List
Einnahme von Betablockern
CL Item
ja (yes)
CL Item
nein (no)
CL Item
unbekannt (unknown)
CL Item
nicht erhoben (not assessed)
Duration of exercise test
Item
Belastungsdauer
time
C0449238 (UMLS CUI [1,1])
C2959886 (UMLS CUI [1,2])
Item
Belastungsart: Laufband
text
C2959886 (UMLS CUI [1,1])
C0184069 (UMLS CUI [1,2])
C0332307 (UMLS CUI [1,3])
Code List
Belastungsart: Laufband
CL Item
modifiziertes Jones Protokoll (modified Jones protocol)
CL Item
WHO-Protokoll (WHO protocol)
CL Item
unbekannt (unknown)
CL Item
nicht erhoben (not assessed)
Item
Belastungsart: Fahrrad
text
C0005375 (UMLS CUI [1,1])
C2959886 (UMLS CUI [1,2])
C0332307 (UMLS CUI [1,3])
Code List
Belastungsart: Fahrrad
CL Item
Bruce-Protokoll (Bruce protocol)
CL Item
WHO-Protokoll (WHO protocol)
CL Item
modifiziertes Bruce-Protokoll (modified Bruce protocol)
CL Item
modifiziertes Naughton-Protokoll (modified Naughton protocol)
CL Item
unbekannt (unknown)
CL Item
nicht erhoben (not assessed)
Item
Abbruchgrund
text
C0457454 (UMLS CUI [1,1])
C0566251 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
CL Item
Ausbelastung erreicht (maximum exertion reached)
CL Item
ST-StreckenSenkungen (> 0,2 mV) oder Hebungen (ST segment depression (> 0.2 mV) or elevation)
CL Item
Progrediente atriale oder ventrikuläre Arrhythmien oder Blockbilder (progressive atrial or ventricular arrhythmias or bundle branch block patterns)
CL Item
Frequenzabfall unter Belastung (frequency decrease during exercise)
CL Item
Fehlender RR-Anstieg bzw. RRAbfall über 2 Belastungsstufen (missing BP increase or BP decrease over 2 exercise levels)
CL Item
Maximale Erschöpfung (z.B. der Beine) (maximum exhaustion (e.g. of legs))
CL Item
Thoraxschmerzen (z.B. AP-Symptomatik),starker Schwindel (chest pain (e.g. AP symptoms), severe dizziness)
CL Item
Übermäßige Dyspnoe (excessive dyspnoea)
CL Item
Proband zeigt Wunsch nach Abbruch an (subject's expression of the wish to terminate the test)
CL Item
unbekannt (unknown)
CL Item
nicht erhoben (not assessed)
CL Item
Neu aufgetretenes Vorhofflimmern (Newly occurring atrial fibrillation)
CL Item
Abfall der 02 Aufnahme (bzw. Sauerstoffpulses) trotz Steigerung der Last (Drop in O2 uptake (or oxygen pulse) in spite of increasing the load)
Heart rate at rest
Item
HF (Ruhe)
integer
C0018810 (UMLS CUI [1,1])
C0443144 (UMLS CUI [1,2])
Maximum heart rate during Cardiopulmonary Exercise Test
Item
HFmax (Belastung)
integer
C0018810 (UMLS CUI [1,1])
C0806909 (UMLS CUI [1,2])
C0347984 (UMLS CUI [1,3])
C2959886 (UMLS CUI [1,4])
Heart Rate after Cardiopulmonary Exercise Test
Item
HF (1min nach Belastung)
integer
C0018810 (UMLS CUI [1,1])
C0687676 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
Systolic BP (at rest)
Item
RRsys (Ruhe)
integer
C2039694 (UMLS CUI [1])
Diastolic BP (at rest)
Item
RRdia (Ruhe)
integer
C2183311 (UMLS CUI [1])
Systolic BP during Cardiopulmonary Exercise Test
Item
RRsys (Belastung)
integer
C0871470 (UMLS CUI [1,1])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
Diastolic BP during Cardiopulmonary Exercise Test
Item
RRdia (Belastung)
integer
C0347984 (UMLS CUI [1,1])
C2959886 (UMLS CUI [1,2])
C0428883 (UMLS CUI [1,3])
Maximum power in Cardiopulmonary Exercise Test
Item
Watt (max)
integer
C0806909 (UMLS CUI [1,1])
C3854080 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
VE/VCO2 (at rest)
Item
VE/VCO2 (Ruhe)
float
C1301655 (UMLS CUI [1,1])
C0429247 (UMLS CUI [1,2])
C0443144 (UMLS CUI [1,3])
VE/VCO2 during Cardiopulmonary Exercise Test
Item
VE/VCO2 (Belastung)
float
C1301655 (UMLS CUI [1,1])
C0429247 (UMLS CUI [1,2])
C0347984 (UMLS CUI [1,3])
C2959886 (UMLS CUI [1,4])
End-tidal CO2 partial pressure (at rest)
Item
PET CO2 (Ruhe)
integer
C0428664 (UMLS CUI [1,1])
C0443144 (UMLS CUI [1,2])
End-tidal CO2 partial pressure during Cardiopulmonary Exercise Test
Item
PET CO2 (Belastung)
integer
C0428664 (UMLS CUI [1,1])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
VE/VCO2 slope
Item
VE/VCO2-slope
integer
C1301655 (UMLS CUI [1,1])
C0429247 (UMLS CUI [1,2])
C0807955 (UMLS CUI [1,3])
VO2 (at rest)
Item
VO2 (Ruhe)
float
C0030055 (UMLS CUI [1,1])
C0443144 (UMLS CUI [1,2])
Item
VO2 (at rest)
text
C0030055 (UMLS CUI [1,1])
C0443144 (UMLS CUI [1,2])
C1519795 (UMLS CUI [1,3])
Code List
VO2 (at rest)
CL Item
ml/min (ml/min)
CL Item
l/min (l/min)
VO2 peak
Item
VO2 peak
integer
C1305742 (UMLS CUI [1,1])
C0444505 (UMLS CUI [1,2])
VO2 Norm
Item
VO2 Norm
float
C0030055 (UMLS CUI [1,1])
C0086715 (UMLS CUI [1,2])
Item
VO2 Norm
text
C0030055 (UMLS CUI [1,1])
C0086715 (UMLS CUI [1,2])
C1519795 (UMLS CUI [1,3])
Code List
VO2 Norm
CL Item
ml/min (ml/min)
CL Item
l/min (l/min)
VO2 at aerobic/anaerobic threshold
Item
VO2 AT
float
C0030055 (UMLS CUI [1,1])
C0002749 (UMLS CUI [1,2])
Item
VO2 AT
text
C0030055 (UMLS CUI [1,1])
C0002749 (UMLS CUI [1,2])
C1519795 (UMLS CUI [1,3])
Code List
VO2 AT
CL Item
ml/min (ml/min)
CL Item
l/min (l/min)
Maximum minute volume during exhalation
Item
VE max
integer
C1959925 (UMLS CUI [1,1])
C0806909 (UMLS CUI [1,2])
Respiratory rate (at rest)
Item
AF (Ruhe)
integer
C0231832 (UMLS CUI [1,1])
C0443144 (UMLS CUI [1,2])
Respiratory rate during Cardiopulmonary Exercise Test
Item
AF (Belastung)
integer
C0231832 (UMLS CUI [1,1])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
Respiratory rate maximum
Item
AF max
integer
C0231832 (UMLS CUI [1,1])
C0806909 (UMLS CUI [1,2])
VT (at rest)
Item
VT (Ruhe)
float
C0040210 (UMLS CUI [1,1])
C0443144 (UMLS CUI [1,2])
VT during Cardiopulmonary Exercise Test
Item
VT (Belastung)
float
C0040210 (UMLS CUI [1,1])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
VD/VT (at rest)
Item
VD/VT (Ruhe)
float
C0429747 (UMLS CUI [1,1])
C0443144 (UMLS CUI [1,2])
VD/VT during Cardiopulmonary Exercise Test
Item
VD/VT (Belastung)
float
C0429747 (UMLS CUI [1,1])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
Saturation sO2 (at rest)
Item
Sättigung sO2 (Ruhe)
integer
C0523807 (UMLS CUI [1,1])
C0443144 (UMLS CUI [1,2])
Saturation sO2 during Cardiopulmonary Exercise Test
Item
Sättigung sO2 (Belastung)
integer
C0523807 (UMLS CUI [1,1])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
Respiratory quotient (RQ) at rest
Item
Respiratorischer Quotient (RQ) Ruhe
float
C0199508 (UMLS CUI [1,1])
C0443144 (UMLS CUI [1,2])
Respiratory quotient (RQ) during Cardiopulmonary Exercise Test
Item
Respiratorischer Quotient (RQ) Belastung
float
C0199508 (UMLS CUI [1,1])
C0347984 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
Respiratory quotient (RQ) after Cardiopulmonary Exercise Test
Item
Respiratorischer Quotient nach Belastungsende (RQ maxpost)
float
C0199508 (UMLS CUI [1,1])
C0687676 (UMLS CUI [1,2])
C2959886 (UMLS CUI [1,3])
Item
Verwendete BORG-Skala
text
C0332307 (UMLS CUI [1,1])
C0449399 (UMLS CUI [1,2])
Code List
Verwendete BORG-Skala
CL Item
Borg-Antrengungsskala (6/20) (Borg rating of perceived exertion scale (6/20))
CL Item
unbekannt (unknown)
CL Item
nicht erhoben (not assessed)
CL Item
Borg-Atemnot-Skala (0/10) (Borg – dyspnoea scale (0/10))
Item
Borg-Antrengungsskala
text
C4055363 (UMLS CUI [1])
Code List
Borg-Antrengungsskala
CL Item
6 (6)
CL Item
7 (7)
CL Item
8 (8)
CL Item
9 (9)
CL Item
10 (10)
CL Item
11 (11)
CL Item
12 (12)
CL Item
13 (13)
CL Item
14 (14)
CL Item
15 (15)
CL Item
16 (16)
CL Item
17 (17)
CL Item
18 (18)
CL Item
19 (19)
CL Item
20 (20)
CL Item
unbekannt (unknown)
CL Item
nicht erhoben (not assessed)
Item
Borg-Atemnot-Skala
text
C0449399 (UMLS CUI [1,1])
C0013404 (UMLS CUI [1,2])
Code List
Borg-Atemnot-Skala
CL Item
0 (0)
CL Item
0.5 (0.5)
CL Item
1 (1)
CL Item
2 (2)
CL Item
3 (3)
CL Item
4 (4)
CL Item
5 (5)
CL Item
6 (6)
CL Item
7 (7)
CL Item
8 (8)
CL Item
9 (9)
CL Item
10 (10)
CL Item
unbekannt (unknown)
CL Item
nicht erhoben (not assessed)

Utilice este formulario para comentarios, preguntas y sugerencias.

Los campos marcados con * son obligatorios.

Do you need help on how to use the search function? Please watch the corresponding tutorial video for more details and learn how to use the search function most efficiently.

Watch Tutorial