ID
38292
Description
With permission from the DZHK administrative office. http://dzhk.de The DZHK (Deutsches Zentrum für Herz-Kreislauf-Forschung e.V.; German Center for Cardiovascular Research) is a joint cooperation of twenty-eight institutions in seven locations throughout Germany to develop a common research strategy. They developed a data catalogue with metadata and data as well as information about available biological materials from all their studies. For more information on the data catalogue and access to actual data and biosamples please visit https://dzhk.de/en/resources/data-manual/ . This version contains the metadata part only. The form6-Minute Walking Test is used to document the results of the 6-minute walking test. The test evaluates the functional reserves and the degree of physical tolerance of patients with chronic heart and lung diseases in their individual daily life as well as it records the course of the disease and the success of therapeutic measures. The time between this test and other physical stress tests (e.g. ergometry or cardiovascular exercise test) should not be less than 2 hours; ideally, the examination should be performed on a different day. This form uses the Borg scales of dyspnoea (Borg, G.A., Psychophysical bases of perceived exertion. Medicine and science in sports and exercise, 1982. 14(5): p. 377-81) and exertion (Borg, G., Anstrengungsempfinden und körperliche Aktivität. Dtsch Arztebl International, 2004. 101(15): p. 1016-). The documentation is to be performed according to the DZHK's SOPs, which can be accessed at https://dzhk.de/en/resources/sops/ (or https://dzhk.de/ressourcen/sops/ for the German language versions). The SOP for this form is "6-minute walking test (6MWT)" (version 1.0, valid as of 01/09/2014) for the English language version, and "6-Minuten-Gehtest (6MWT)" (version 1.0, valid as of 01/09/2014) for the German version.
Link
Keywords
Versions (1)
- 10/8/19 10/8/19 -
Copyright Holder
DZHK
Uploaded on
October 8, 2019
DOI
To request one please log in.
License
Creative Commons BY-NC 3.0
Model comments :
You can comment on the data model here. Via the speech bubbles at the itemgroups and items you can add comments to those specificially.
Itemgroup comments for :
Item comments for :
In order to download data models you must be logged in. Please log in or register for free.
DZHK Data Catalogue
6-Minute Walking Test
- StudyEvent: ODM
Description
Examination
Alias
- UMLS CUI-1
- C0031809
Description
Measurement of resting blood pressure and heart rate?
Data type
text
Alias
- UMLS CUI [1,1]
- C0005824
- UMLS CUI [1,2]
- C0443144
- UMLS CUI [2,1]
- C1821417
- UMLS CUI [2,2]
- C0242485
Description
Systolic blood pressure
Data type
integer
Measurement units
- mmHg
Alias
- UMLS CUI [1]
- C0871470
Description
Diastolic blood pressure
Data type
integer
Measurement units
- mmHg
Alias
- UMLS CUI [1]
- C0428883
Description
Heart rate
Data type
integer
Measurement units
- /min
Alias
- UMLS CUI [1]
- C0018810
Description
6MWT distance
Data type
integer
Measurement units
- m
Alias
- UMLS CUI [1]
- C3900190
Description
Borg Scale
Alias
- UMLS CUI-1
- C0449399
Description
When the patient stands up to carry out the test, first measure his degree of dyspnoea using the BORG Dyspnoea Scale. The Borg scale should be available as a hard copy with an adequate font size (at least 20 pt).
Data type
text
Alias
- UMLS CUI [1,1]
- C0449399
- UMLS CUI [1,2]
- C0332152
- UMLS CUI [1,3]
- C0430515
Description
When the six minutes are over, say "Stop" loud and clearly. The examiner then walks to where the patient is standing. If the patient is very exhausted, offer him a chair to sit down on. Afterwards, reassess the degree of dyspnoea using the BORG Dyspnoea or Exertion Scale – the type of scale to be used has to be stipulated in the respective study/the respective registry. Used BORG scale (after end of test)
Data type
text
Alias
- UMLS CUI [1,1]
- C0332307
- UMLS CUI [1,2]
- C0449399
- UMLS CUI [1,3]
- C0687676
- UMLS CUI [1,4]
- C0430515
Description
When the six minutes are over, say "Stop" loud and clearly. The examiner then walks to where the patient is standing. If the patient is very exhausted, offer him a chair to sit down on. Afterwards, reassess the degree of dyspnoea using the BORG Dyspnoea or Exertion Scale – the type of scale to be used has to be stipulated in the respective study/the respective registry. Borg rating of perceived exertion scale
Data type
text
Alias
- UMLS CUI [1,1]
- C4055363
- UMLS CUI [1,2]
- C0687676
- UMLS CUI [1,3]
- C0430515
Description
When the six minutes are over, say "Stop" loud and clearly. The examiner then walks to where the patient is standing. If the patient is very exhausted, offer him a chair to sit down on. Afterwards, reassess the degree of dyspnoea using the BORG Dyspnoea or Exertion Scale – the type of scale to be used has to be stipulated in the respective study/the respective registry
Data type
text
Alias
- UMLS CUI [1,1]
- C0449399
- UMLS CUI [1,2]
- C0687676
- UMLS CUI [1,3]
- C0430515
Description
Aids/stop criteria
Alias
- UMLS CUI-1
- C0872018
- UMLS CUI-2
- C4321457
- UMLS CUI-3
- C0014672
- UMLS CUI-4
- C0243161
- UMLS CUI-5
- C0457454
- UMLS CUI-6
- C0430515
Description
The walking path should be 30 metres long and be marked every 3 metres, whereby the start and the turning point should be marked in colour and easy to recognise (standard method). Alternatively, a measuring wheel can be used to measure the distance walked. chair telephone with easy reach Defibrillator within easy reach Possibility of oxygen supply
Data type
text
Alias
- UMLS CUI [1]
- C0872018
- UMLS CUI [2,1]
- C4321457
- UMLS CUI [2,2]
- C0014672
Description
If yes, select aids
Data type
text
Alias
- UMLS CUI [1,1]
- C1521902
- UMLS CUI [1,2]
- C0872018
- UMLS CUI [2,1]
- C1521902
- UMLS CUI [2,2]
- C4321457
- UMLS CUI [2,3]
- C0014672
Description
Specify aids/examination equipment
Data type
text
Alias
- UMLS CUI [1,1]
- C1521902
- UMLS CUI [1,2]
- C0872018
- UMLS CUI [2,1]
- C1521902
- UMLS CUI [2,2]
- C4321457
- UMLS CUI [2,3]
- C0014672
Description
The test is terminated if any of the following symptoms occur: - Angina pectoris - Severe dyspnoea - Dizziness - Unsafe gait, risk of falling - Calf cramps - Claudication - If the oxygen saturation is being measured, the test is: - interrupted from a drop of saturation to < 90 % and repeated after a period of rest with a permanent oxygen supply of 2 litres/min. - stopped completely in case of a drop in oxygen saturation to less than 85%.
Data type
text
Alias
- UMLS CUI [1,1]
- C0457454
- UMLS CUI [1,2]
- C0430515
- UMLS CUI [1,3]
- C4018905
Description
In case the test was stopped prematurely: Total test time. Minutes and seconds.
Data type
time
Alias
- UMLS CUI [1,1]
- C0457454
- UMLS CUI [1,2]
- C0430515
- UMLS CUI [1,3]
- C0449238
Description
Reason for stopping
Data type
text
Alias
- UMLS CUI [1,1]
- C0457454
- UMLS CUI [1,2]
- C0430515
- UMLS CUI [1,3]
- C0566251
Description
Specify reason for stopping
Data type
text
Alias
- UMLS CUI [1,1]
- C1521902
- UMLS CUI [1,2]
- C0566251
- UMLS CUI [1,3]
- C0457454
- UMLS CUI [1,4]
- C0430515
Description
Other particular findings?
Data type
text
Alias
- UMLS CUI [1,1]
- C1335151
- UMLS CUI [1,2]
- C0750502
Description
If yes, specify other particular findings
Data type
text
Alias
- UMLS CUI [1,1]
- C1521902
- UMLS CUI [1,2]
- C1335151
- UMLS CUI [1,3]
- C0750502
Description
Please specify other particular findings
Data type
text
Alias
- UMLS CUI [1,1]
- C1521902
- UMLS CUI [1,2]
- C1335151
- UMLS CUI [1,3]
- C0750502
Similar models
6-Minute Walking Test
- StudyEvent: ODM
C0430515 (UMLS CUI-2)
C0884358 (UMLS CUI [1,2])
C0011008 (UMLS CUI [1,2])
C0600091 (UMLS CUI [1,2])
C0443144 (UMLS CUI [1,2])
C1821417 (UMLS CUI [2,1])
C0242485 (UMLS CUI [2,2])
C0332152 (UMLS CUI [1,2])
C0430515 (UMLS CUI [1,3])
C0449399 (UMLS CUI [1,2])
C0687676 (UMLS CUI [1,3])
C0430515 (UMLS CUI [1,4])
C0687676 (UMLS CUI [1,2])
C0430515 (UMLS CUI [1,3])
C0687676 (UMLS CUI [1,2])
C0430515 (UMLS CUI [1,3])
C4321457 (UMLS CUI-2)
C0014672 (UMLS CUI-3)
C0243161 (UMLS CUI-4)
C0457454 (UMLS CUI-5)
C0430515 (UMLS CUI-6)
C4321457 (UMLS CUI [2,1])
C0014672 (UMLS CUI [2,2])
C0872018 (UMLS CUI [1,2])
C1521902 (UMLS CUI [2,1])
C4321457 (UMLS CUI [2,2])
C0014672 (UMLS CUI [2,3])
C0872018 (UMLS CUI [1,2])
C1521902 (UMLS CUI [2,1])
C4321457 (UMLS CUI [2,2])
C0014672 (UMLS CUI [2,3])
C0430515 (UMLS CUI [1,2])
C4018905 (UMLS CUI [1,3])
C0430515 (UMLS CUI [1,2])
C0449238 (UMLS CUI [1,3])
C0430515 (UMLS CUI [1,2])
C0566251 (UMLS CUI [1,3])
C0566251 (UMLS CUI [1,2])
C0457454 (UMLS CUI [1,3])
C0430515 (UMLS CUI [1,4])
C0750502 (UMLS CUI [1,2])
C1335151 (UMLS CUI [1,2])
C0750502 (UMLS CUI [1,3])
C1335151 (UMLS CUI [1,2])
C0750502 (UMLS CUI [1,3])
No comments