ID
6500
Description
Documentation form for quality assurance in German Health Care by the institute forapplied quality Improvement and Research in Health Care (Aqua), https://www.aqua-institut.de/en/home. Internal Aqua form version: 09-4 Specification 2015 V02
Link
https://www.aqua-institut.de/en/home
Keywords
Versions (2)
- 12/22/14 12/22/14 - Julian Varghese
- 1/7/15 1/7/15 - Julian Varghese
Uploaded on
January 7, 2015
DOI
To request one please log in.
License
Creative Commons BY-NC 3.0 Legacy
Model comments :
You can comment on the data model here. Via the speech bubbles at the itemgroups and items you can add comments to those specificially.
Itemgroup comments for :
Item comments for :
In order to download data models you must be logged in. Please log in or register for free.
Quality assurance Implantable Defibrillator: Implantation (AQUA)
Quality assurance Implantable Defibrillator: Implantation (AQUA)
Description
Preoperative Clinical Examination
Description
Herzinsuffizienz
Data type
integer
Alias
- UMLS CUI-1
- C1882083
Description
Einstufung nach ASA-Klassifikation
Data type
integer
Alias
- UMLS CUI-1
- C1531480
Description
linksventrikuläre Ejektionsfraktion
Data type
integer
Measurement units
- %
Alias
- UMLS CUI-1
- C0428772
Description
LVEF nicht bekannt
Data type
integer
Description
Diabetes mellitus
Data type
integer
Alias
- UMLS CUI-1
- C0011849
Description
Nierenfunktion/Serum Kreatinin
Data type
integer
Alias
- UMLS CUI-1
- C0201976
Description
Part ICD (Implantable cardioverter defibrillator)
Description
führende Indikation für ICD-Implantation
Data type
integer
Alias
- UMLS CUI-1
- C0392360
- UMLS CUI-2
- C0162589
Description
indikationsbegründendes klinisches Ereignis
Data type
integer
Description
führende klinische Symptomatik (der Arrhythmie)
Data type
integer
Alias
- UMLS CUI-1
- C2609416
Description
Indikation zur kardialen Resynchronisationstherapie (CRT)
Data type
integer
Alias
- UMLS CUI-1
- C0392360
- UMLS CUI-2
- C1167956
Description
Medical history
Description
KHK
Data type
integer
Alias
- UMLS CUI-1
- C0010068
Description
Abstand Myokardinfarkt – Implantation ICD
Data type
integer
Alias
- UMLS CUI-1
- C0872291
Description
indikationsbegründendes klinisches Ereignis innerhalb von 48h nach Infarktbeginn
Data type
boolean
Description
Herzerkrankung
Data type
integer
Alias
- UMLS CUI-1
- C0018799
Description
plötzliche Todesfälle in der Familie
Data type
integer
Alias
- UMLS CUI-1
- C2315244
Description
abnorme Blutdruckreaktion bei Belastung (Blutdruckanstieg <= 20 mmHg)
Data type
integer
Alias
- UMLS CUI-1
- C2041044
Description
Septumdicke >= 30 mm
Data type
integer
Alias
- UMLS CUI-1
- C2215790
Description
ausgeprägte rechtsventrikuläre Dysplasie oder linksventrikuläre Beteiligung
Data type
integer
Alias
- UMLS CUI-1
- C0344887
- UMLS CUI-2
- C0344905
Description
WPW-Syndrom
Data type
integer
Alias
- UMLS CUI-1
- C0043202
Description
reversible oder sicher vermeidbare Ursachen der Kammertachykardie
Data type
integer
Alias
- UMLS CUI-1
- C0035648
- UMLS CUI-2
- C0042514
Description
behandelbare idiopathische Kammertachykardie
Data type
integer
Alias
- UMLS CUI-1
- C0030591
Description
Further characteristics
Description
Kammertachykardie induzierbar
Data type
integer
Alias
- UMLS CUI-1
- C0340486
Description
medikamentöse Herzinsuffizienztherapie (zum Zeitpunkt der Diagnosestellung)
Data type
boolean
Alias
- UMLS CUI-1
- C3495064
Description
Betablocker
Data type
integer
Alias
- UMLS CUI-1
- C0001645
Description
AT-Rezeptor-Blocker / ACE-Hemmer
Data type
integer
Alias
- UMLS CUI-1
- C1971311
Description
Diuretika
Data type
integer
Alias
- UMLS CUI-1
- C0012798
Description
Aldosteronantagonisten
Data type
integer
Alias
- UMLS CUI-1
- C0002007
Description
Herzglykoside
Data type
integer
Alias
- UMLS CUI-1
- C0007158
Description
Part Cardiac pacemaker
Description
ECG findings
Description
Vorhofrhythmus
Data type
integer
Alias
- UMLS CUI-1
- C0232203
Description
AV-Block
Data type
integer
Alias
- UMLS CUI-1
- C0004245
Description
intraventrikuläre Leitungsstörungen
Data type
integer
Alias
- UMLS CUI-1
- C0264909
Description
QRS-Komplex
Data type
integer
Alias
- UMLS CUI-1
- C1287080
Description
Operation
Description
Access point of implanted system
Alias
- UMLS CUI-1-1
- C0587266
- UMLS CUI-1-2
- C0189842
Description
Vena cephalica
Data type
integer
Description
Vena subclavia
Data type
integer
Description
andere
Data type
integer
Description
Dauer des Eingriffs
Data type
integer
Measurement units
- Minuten
Alias
- UMLS CUI-1
- C1442476
Description
Flächendosisprodukt
Data type
integer
Measurement units
- (cGy)* cm²
Description
Flächendosisprodukt nicht bekannt
Data type
integer
Description
intraoperativer Defibrillationstest durchgeführt
Data type
integer
Description
Sicherheitsabstand Test- (oder DFT-) zu aggregatspezifischer Maximalenergie >= 10 J
Data type
boolean
Description
ICD: ICD-System
Description
System
Data type
integer
Alias
- UMLS CUI-1
- C2048304
Description
ICD aggregate
Description
Hersteller
Data type
integer
Description
Aggregatposition
Data type
integer
Description
Electrodes: Atrium (atriale Pace/Sense-electrode)-
Description
Hersteller
Data type
integer
Description
Reizschwelle
Data type
integer
Measurement units
- V
Alias
- UMLS CUI-1
- C2048070
Description
nicht gemessen
Data type
integer
Description
P-Wellen-Amplitude
Data type
integer
Measurement units
- mV
Alias
- UMLS CUI-1
- C0429042
Description
nicht gemessen
Data type
integer
Description
Electrodes: Ventricle
Description
First ventricular/defibrillation electrode
Description
Hersteller
Data type
integer
Description
Defibrillations-Elektroden
Data type
integer
Description
Position
Data type
integer
Description
Reizschwelle
Data type
integer
Measurement units
- V
Alias
- UMLS CUI-1
- C2048285
Description
nicht gemessen
Data type
integer
Description
R-Amplitude
Data type
integer
Measurement units
- mV
Alias
- UMLS CUI-1
- C0429049
Description
nicht gemessen
Data type
integer
Description
Second ventricular electrode
Description
Hersteller
Data type
integer
Description
Position
Data type
integer
Description
Reizschwelle
Data type
integer
Measurement units
- V
Alias
- UMLS CUI-1
- C2048378
Description
nicht gemessen
Data type
integer
Description
R-Amplitude
Data type
integer
Measurement units
- mV
Alias
- UMLS CUI-1
- C0429049
Description
nicht gemessen
Data type
integer
Description
Third ventricular electrode
Description
Hersteller
Data type
integer
Description
Position
Data type
integer
Description
Reizschwelle
Data type
integer
Measurement units
- V
Description
nicht gemessen
Data type
integer
Description
R-Amplitude
Data type
integer
Measurement units
- mV
Alias
- UMLS CUI-1
- C0429049
Description
nicht gemessen
Data type
integer
Description
Other defibrillator electrodes
Description
Perioperative complications
Description
perioperative Komplikation(en)
Data type
boolean
Alias
- UMLS CUI-1
- C0946279
Description
kardiopulmonale Reanimation
Data type
integer
Alias
- UMLS CUI-1
- C0007203
Description
interventionspflichtiger Pneumothorax
Data type
integer
Alias
- UMLS CUI-1
- C0032326
Description
interventionspflichtiger Hämatothorax
Data type
integer
Alias
- UMLS CUI-1
- C0019123
Description
interventionspflichtiger Perikarderguss
Data type
integer
Alias
- UMLS CUI-1
- C0031039
Description
interventionspflichtiges Taschenhämatom
Data type
integer
Alias
- UMLS CUI-1
- C2586079
Description
revisionsbedürftige Sondendislokation
Data type
integer
Alias
- UMLS CUI-1
- C0340936
Description
Location of electrode dislocation
Description
Vorhof
Data type
integer
Description
erste Ventrikelsonde/Defibrillationssonde
Data type
integer
Description
zweite Ventrikelsonde
Data type
integer
Description
dritte Ventrikelsonde
Data type
integer
Description
andere Defibrillationssonde
Data type
integer
Description
revisionsbedürftige Sondendysfunktion
Data type
integer
Alias
- UMLS CUI-1
- C0340934
Description
Location of electrode dysfunction
Description
Vorhof
Data type
integer
Description
erste Ventrikelsonde/Defibrillationssonde
Data type
integer
Description
zweite Ventrikelsonde
Data type
integer
Description
dritte Ventrikelsonde
Data type
integer
Description
andere Defibrillationssonde
Data type
integer
Description
postoperative Wundinfektion
Data type
integer
Alias
- UMLS CUI-1
- C1629491
Description
CDC-Klassifikation
Data type
integer
Description
sonstige interventionspflichtige Komplikation
Data type
integer
Description
Discharge
Description
Entlassungsdatum Krankenhaus
Data type
date
Alias
- UMLS CUI-1
- C2710998
Description
Entlassungsgrund
Data type
integer
Alias
- UMLS CUI-1
- C3164834
Description
Entlassungsdiagnose(n)
Data type
integer
Alias
- UMLS CUI-1
- C0011900
Similar models
Quality assurance Implantable Defibrillator: Implantation (AQUA)
C0162589 (UMLS CUI-2)
C1167956 (UMLS CUI-2)
C0344905 (UMLS CUI-2)
C0042514 (UMLS CUI-2)
C0189842 (UMLS CUI-1-2)