OMOP Common Data Model (CDM) Device Exposure The 'Device' domain captures information about a person's exposure to a foreign physical object or instrument which is used for diagnostic or therapeutic purposes through a mechanism beyond chemical action. Devices include implantable objects (e.g. pacemakers, stents, artificial joints), medical equipment and supplies (e.g. bandages, crutches, syringes), other instruments used in medical procedures (e.g. sutures, defibrillators) and material used in clinical care (e.g. adhesives, body material, dental material, surgical material). The Observational Medical Outcomes Partnership (OMOP) was a public-private partnership established to inform the appropriate use of observational healthcare databases for studying the effects of medical products. © 2014 Observational Health Data Sciences and Informatics. Version updated on 12.02.2019, from https://github.com/OHDSI/CommonDataModel/wiki/DEVICE_EXPOSURE The distinction between Devices or supplies and Procedures are sometimes blurry, but the former are physical objects while the latter are actions, often to apply a Device or supply. Valid Device Concepts belong to the 'Device' domain. The Concepts of this domain are derived from the DI portion of a UDI or based on other source vocabularies, like HCPCS. A Device Type is assigned to each Device Exposure to track from what source the information was drawn or inferred. The valid vocabulary for these Concepts is 'Device Type'. The Visit during which the Device was first used is recorded through a reference to the VISIT_OCCURRENCE table. The Visit Detail during which the Device was first used is recorded through a reference to the VISIT_DETAIL table. The Provider exposing the patient to the Device is recorded through a reference to the PROVIDER table. When dealing with duplicate records, the ETL must determine whether to sum them up into one record or keep them separate. Things to consider are: Same Device/Procedure Same DEVICE_EXPOSURE_START_DATETIME Same Visit Occurrence or Visit Detail Same Provider Same Modifier for Procedures Same COST_ID If a Device Exposure has a quantity of '0' in the source, this should default to '1' in the ETL. If there is a record in the source it can be assumed the exposure occurred at least once.
collegamento
https://github.com/OHDSI/CommonDataModel/wiki/DEVICE_EXPOSURE
Keywords
versioni (3)
- 04/01/17 04/01/17 -
- 12/02/19 12/02/19 -
- 28/02/19 28/02/19 -
Titolare del copyright
Observational Medical Outcomes Partnership (OMOP)
Caricato su
12 febbraio 2019
DOI
Per favore, per richiedere un accesso.
Licenza
Creative Commons BY-NC 3.0
Commenti del modello :
Puoi commentare il modello dati qui. Tramite i fumetti nei gruppi di articoli e articoli è possibile aggiungere commenti a quelli in modo specifico.
Commenti del gruppo di articoli per :
Commenti dell'articolo per :
Per scaricare i modelli di dati devi essere registrato. Per favore accesso o registrati GRATIS.
OMOP Common Data Model (CDM) Device Exposure
OMOP Common Data Model (CDM) Device Exposure
- StudyEvent: ODM
Similar models
OMOP Common Data Model (CDM) Device Exposure
- StudyEvent: ODM
C0332157 (UMLS CUI [1,2])
C1300638 (UMLS CUI [1,3])
C0178566 (UMLS CUI [1,2])
C1300638 (UMLS CUI [1,3])
C0332157 (UMLS CUI [1,2])
C0808070 (UMLS CUI [1,3])
C0332157 (UMLS CUI [1,2])
C0808070 (UMLS CUI [1,3])
C0699733 (UMLS CUI [2,1])
C0332157 (UMLS CUI [2,2])
C1301880 (UMLS CUI [2,3])
C0332157 (UMLS CUI [1,2])
C0806020 (UMLS CUI [1,3])
C0332157 (UMLS CUI [1,2])
C0806020 (UMLS CUI [1,3])
C0699733 (UMLS CUI [2,1])
C0332157 (UMLS CUI [2,2])
C1522314 (UMLS CUI [2,3])
C0332307 (UMLS CUI [1,2])
C0178566 (UMLS CUI [1,3])
C1300638 (UMLS CUI [1,4])
C0699733 (UMLS CUI [1,2])
C1300638 (UMLS CUI [1,2])
C2745955 (UMLS CUI [1,2])
C1300638 (UMLS CUI [1,3])
C1522508 (UMLS CUI [1,2])
C1300638 (UMLS CUI [1,3])
C0449416 (UMLS CUI [1,2])
C0805701 (UMLS CUI [1,3])
C0600091 (UMLS CUI [1,4])
C0449416 (UMLS CUI [1,2])
C0178566 (UMLS CUI [1,3])
C1300638 (UMLS CUI [1,4])