ID
29643
Descrizione
http://openehr.org/ckm/ Use to record measurements taken during tympanometry with a 226 Hz probe tone. Use to record outcome of tympanometry screening based on 226 Hz probe tone tympanometry. Use to record the interpretation all tympanogram measurements taken with a 226 Hz probe tone, to infer middle ear function for each ear, plus an overall interpretation (or tympanometric diagnosis). All of the data elements are recorded using a single method or protocol. If, during the test, any of the protocol parameters need to be modified, then the subsequent part of the test will need to be recorded within a separate instance of the test data, using the updated protocol parameters. Each 'Pressure vs Compliance Measurement' pair will comprise one pressure measurment with one corresponding compliance measurement. Compliance measurement has been represented in the archetype twice, each with different units. Compliance measurements will only be recorded in data using the unit that is recorded by the tympanometer in use - either volume units OR conductance units, but not both. Similarly, Static Compliance has been represented in the archetype twice, each with different units. Static Compliance measurements will only be recorded in data using the unit that is recorded by the tympanometer in use - either volume units OR conductance units, but not both. If the tympanogram subtypes are to be used in an implementation, these should be substituted for the global Type B category in the 'Tympanogram Type' data element. Both 'Type B' and 'Type B - low/high compliance' should not be used in the same implementation. 'Type B - low complicance' is equivalent to the unqualified 'Type B' in the 'Tympanogram Type' data element. Similarly, if Type C subtypes describing the Tympanogram curve are to be used in an implementation, these should be substituted for the global Type C category in the 'Tympanogram Type' data element. Both Type C and Types C1-3 should not be used in the same implementation.
collegamento
Keywords
versioni (1)
- 10/04/18 10/04/18 - Halim Ugurlu
Titolare del copyright
openEHR Foundation
Caricato su
10 aprile 2018
DOI
Per favore, per richiedere un accesso.
Licenza
Creative Commons BY-NC 3.0
Commenti del modello :
Puoi commentare il modello dati qui. Tramite i fumetti nei gruppi di articoli e articoli è possibile aggiungere commenti a quelli in modo specifico.
Commenti del gruppo di articoli per :
Commenti dell'articolo per :
Per scaricare i modelli di dati devi essere registrato. Per favore accesso o registrati GRATIS.
openEHR-EHR-OBSERVATION.tympanogram_226hz.v1
openEHR-EHR-OBSERVATION.tympanogram_226hz.v1
- StudyEvent: openEHR-EHR-OBSERVATION.tympanogram_226hz.v1
Similar models
openEHR-EHR-OBSERVATION.tympanogram_226hz.v1
- StudyEvent: openEHR-EHR-OBSERVATION.tympanogram_226hz.v1
C1274040 (UMLS CUI [1,2])
C0456984 (UMLS CUI [1,2])
C0449468 (UMLS CUI [1,2])
C0376478 (UMLS CUI [1,2])
C1522508 (UMLS CUI [1,2])
C0460139 (UMLS CUI [1,2])
C3714738 (UMLS CUI [2])
C0085853 (UMLS CUI [1,2])
C0085853 (UMLS CUI [1,2])
C1518422 (UMLS CUI [1,2])
C3841220 (UMLS CUI [1,2])
C0687676 (UMLS CUI [1,2])
C0687676 (UMLS CUI [1,2])
C1138678 (UMLS CUI [1,2])
C0332152 (UMLS CUI [1,3])
C0460139 (UMLS CUI [1,2])
C0392747 (UMLS CUI [1,3])
C0392747 (UMLS CUI [1,2])
C1883165 (UMLS CUI [1,2])
C1514721 (UMLS CUI [1,2])
C0808070 (UMLS CUI [1,2])
C0806020 (UMLS CUI [1,2])
C1522508 (UMLS CUI [1,2])
C0033095 (UMLS CUI [1,2])
C0679573 (UMLS CUI [1,2])
C0679573 (UMLS CUI [1,2])
C0449560 (UMLS CUI [1,2])
C0679573 (UMLS CUI [1,2])