http://openehr.org/ckm/ Use to record measurements taken during tympanometry with a 226 Hz probe tone. Use to record outcome of tympanometry screening based on 226 Hz probe tone tympanometry. Use to record the interpretation all tympanogram measurements taken with a 226 Hz probe tone, to infer middle ear function for each ear, plus an overall interpretation (or tympanometric diagnosis). All of the data elements are recorded using a single method or protocol. If, during the test, any of the protocol parameters need to be modified, then the subsequent part of the test will need to be recorded within a separate instance of the test data, using the updated protocol parameters. Each 'Pressure vs Compliance Measurement' pair will comprise one pressure measurment with one corresponding compliance measurement. Compliance measurement has been represented in the archetype twice, each with different units. Compliance measurements will only be recorded in data using the unit that is recorded by the tympanometer in use - either volume units OR conductance units, but not both. Similarly, Static Compliance has been represented in the archetype twice, each with different units. Static Compliance measurements will only be recorded in data using the unit that is recorded by the tympanometer in use - either volume units OR conductance units, but not both. If the tympanogram subtypes are to be used in an implementation, these should be substituted for the global Type B category in the 'Tympanogram Type' data element. Both 'Type B' and 'Type B - low/high compliance' should not be used in the same implementation. 'Type B - low complicance' is equivalent to the unqualified 'Type B' in the 'Tympanogram Type' data element. Similarly, if Type C subtypes describing the Tympanogram curve are to be used in an implementation, these should be substituted for the global Type C category in the 'Tympanogram Type' data element. Both Type C and Types C1-3 should not be used in the same implementation.
Link
Stichworte
Versionen (1)
- 10.04.18 10.04.18 - Halim Ugurlu
Rechteinhaber
openEHR Foundation
Hochgeladen am
10. April 2018
DOI
Für eine Beantragung loggen Sie sich ein.
Lizenz
Creative Commons BY-NC 3.0
Modell Kommentare :
Hier können Sie das Modell kommentieren. Über die Sprechblasen an den Itemgruppen und Items können Sie diese spezifisch kommentieren.
Itemgroup Kommentare für :
Item Kommentare für :
Um Formulare herunterzuladen müssen Sie angemeldet sein. Bitte loggen Sie sich ein oder registrieren Sie sich kostenlos.
openEHR-EHR-OBSERVATION.tympanogram_226hz.v1
openEHR-EHR-OBSERVATION.tympanogram_226hz.v1
- StudyEvent: openEHR-EHR-OBSERVATION.tympanogram_226hz.v1
Ähnliche Modelle
openEHR-EHR-OBSERVATION.tympanogram_226hz.v1
- StudyEvent: openEHR-EHR-OBSERVATION.tympanogram_226hz.v1
C1274040 (UMLS CUI [1,2])
C0456984 (UMLS CUI [1,2])
C0449468 (UMLS CUI [1,2])
C0376478 (UMLS CUI [1,2])
C1522508 (UMLS CUI [1,2])
C0460139 (UMLS CUI [1,2])
C3714738 (UMLS CUI [2])
C0085853 (UMLS CUI [1,2])
C0085853 (UMLS CUI [1,2])
C1518422 (UMLS CUI [1,2])
C3841220 (UMLS CUI [1,2])
C0687676 (UMLS CUI [1,2])
C0687676 (UMLS CUI [1,2])
C1138678 (UMLS CUI [1,2])
C0332152 (UMLS CUI [1,3])
C0460139 (UMLS CUI [1,2])
C0392747 (UMLS CUI [1,3])
C0392747 (UMLS CUI [1,2])
C1883165 (UMLS CUI [1,2])
C1514721 (UMLS CUI [1,2])
C0808070 (UMLS CUI [1,2])
C0806020 (UMLS CUI [1,2])
C1522508 (UMLS CUI [1,2])
C0033095 (UMLS CUI [1,2])
C0679573 (UMLS CUI [1,2])
C0679573 (UMLS CUI [1,2])
C0449560 (UMLS CUI [1,2])
C0679573 (UMLS CUI [1,2])