Health sector data set specifications from METeOR, Australia's repository for national metadata standards, developed by the Australian Institute of Health and Welfare (http://meteor.aihw.gov.au/content/index.phtml/itemId/345165) Acute coronary syndrome (clinical) DSS 2013-: The scope for the ACS data set specification is to collect data on the period between when a person with ACS symptoms was first referred to a hospital or directly presented at a hospital, and when a person leaves the hospital, either from the emergency department or is discharged from the hospital. Functional stress test cluster: A functional stress test evaluates arterial blood flow to the heart muscle during increased cardiac work through physical exercise or pharmacological methods. The functional stress test cluster collects information on the timing, characteristics and results of a functional stress test performed during the current hospital presentation. Metadata and Classifications Unit Australian Institute of Health and Welfare GPO Box 570 Canberra ACT 2601

Link

http://meteor.aihw.gov.au/content/index.phtml/itemId/345165

Palavras-chave

  1. 04/09/2016 04/09/2016 -
Transferido a

4 de setembro de 2016

DOI

Para um pedido faça login.

Licença

Creative Commons BY-NC 3.0

Comentários do modelo :

Aqui pode comentar o modelo. Pode comentá-lo especificamente através dos balões de texto nos grupos de itens e itens.

Comentários do grupo de itens para :

Comentários do item para :


    Sem comentários

    Para descarregar formulários, precisa de ter uma sessão iniciada. Por favor faça login ou registe-se gratuitamente.

    Acute coronary syndrome (clinical) DSS 2013- Functional stress test cluster Metadata Online Registry (METeOR)

    Acute coronary syndrome (clinical) DSS 2013- Functional stress test cluster Metadata Online Registry (METeOR)

    Functional stress test
    Descrição

    Functional stress test

    Functional stress test assessment of cardiac perfusion
    Descrição

    Functional stress test—assessment of cardiac perfusion, code N[N] Obligation: Conditional Identifying and definitional attributes Short name: Functional stress test assessment of cardiac perfusion Synonymous names: Functional stress test method METeOR identifier: 344432 Registration status: Health, Standard 01/10/2008 Definition: The method of functional assessment of cardiac perfusion undertaken in a person's stress test, as represented by a code. Data Element Concept: Functional stress test—assessment of cardiac perfusion Value domain attributes Representational attributes Representation class: Code Data type: Number Format: N Maximum character length: 1 Permissible values: Value Meaning 1 Exercise tolerance 2 Pharmacological Supplementary values: 9 Not stated/inadequately described Collection and usage attributes Guide for use: CODE 1 Exercise tolerance Use this code when a treadmill, bicycle or arm-exercise was used to increase the cardiac work. CODE 2 Pharmacological Use this code when any form of pharmacologic augmentation was used to increase cardiac work. For example, dobutamine, atropine or persantin. CODE 9 Not stated/inadequately described Not for use in primary data collections. Data set specification specific attributes Functional stress test cluster Conditional obligation: To be provided when a functional stress test is performed. Data element attributes Relational attributes Implementation in Data Set Specifications: Functional stress test cluster Health, Standard 01/10/2008

    Tipo de dados

    integer

    Functional stress ischaemic and perfusion outcome result
    Descrição

    Functional stress test—ischaemic and perfusion outcome result, code N Obligation: Conditional Identifying and definitional attributes Short name: Functional stress ischaemic and perfusion outcome result Synonymous names: Functional stress test result METeOR identifier: 349703 Registration status: Health, Standard 01/10/2008 Definition: The result of the person's functional stress test in terms of ischaemic and perfusion outcomes, as represented by a code. Data Element Concept: Functional stress test—ischaemic and perfusion outcome result Value domain attributes Representational attributes Representation class: Code Data type: Number Format: N Maximum character length: 1 Permissible values: Value Meaning 1 No abnormal outcome 2 Ischaemic discomfort and/or ST shift 3 Fixed perfusion or wall motion defects only 4 Reversible perfusion or wall motion defects only 5 Fixed and reversible perfusion and wall motion defects 6 Equivocal Supplementary values: 9 Not stated/inadequately described Collection and usage attributes Guide for use: Depending on the method used for the stress test, and therefore the way the results are viewed, some of these codes will not be applicable. For example where an ECG was used for the stress test codes 3, 4 and 5 will not be applicable. CODE 1 No abnormal outcome Use this code when the stress test result identifies no evidence of ischaemia (i.e. no typical angina pain and no ST shifts). CODE 2 Ischaemic discomfort and/or ST shift Use this code when the stress test result identifies either: · Both ischaemic discomfort and ST shift greater than or equal to 1 mm (0.1 mV) (horizontal or downsloping); or · new ST shift greater than or equal to 2 mm (0.2 mV) (horizontal or down-sloping) believed to represent ischaemia even in the absence of ischaemic discomfort. This code only applies to stress tests where no imaging component was performed. CODE 3 Fixed perfusion or wall motion defects only Use this code when the stress test result identifies fixed perfusion defects only. This means the presence of non-viable myocardium with no areas of inducible ischaemia during functional stress testing. This code only applies to stress tests where an imaging component was performed. CODE 4 Reversible perfusion or wall motion defects only Use this code when the stress test result identifies reversible perfusion defects only. This means the presence of inducible defects in myocardial perfusion with underlying viable myocardium in all areas. This code only applies to stress tests where an imaging component was performed. CODE 5 Fixed and reversible perfusion or wall motion defects Use this code when the stress test result identifies reversible and fixed perfusion defects. This means the presence of non-viable myocardial areas, together with areas of inducible defects in reperfusion. This code only applies to stress tests where an imaging component was performed. CODE 6 Equivocal Use this code when the stress test result identifies either: · Typical ischaemic pain but no ST shift greater than or equal to 1 mm (0.1 mV) (horizontal or downsloping); OR ST shift of 1 mm (0.1 mV) (horizontal or downsloping) but no ischaemic discomfort. · Defect on myocardial imaging of uncertain nature or significance. Data set specification specific attributes Functional stress test cluster Conditional obligation: To be provided when a functional stress test is performed. Data element attributes Relational attributes Related metadata references: Supersedes Person—functional stress test ischaemic result, code N Health, Superseded 01/10/2008 Implementation in Data Set Specifications: Functional stress test cluster Health, Standard 01/10/2008

    Tipo de dados

    integer

    Functional stress test element
    Descrição

    Functional stress test—stress test element, code N Obligation: Conditional Identifying and definitional attributes Short name: Functional stress test element METeOR identifier: 356883 Registration status: Health, Standard 01/10/2008 Definition: The element included in a person's functional stress test, as represented by a code. Data Element Concept: Functional stress test—functional stress test element Value domain attributes Representational attributes Representation class: Code Data type: Number Format: N Maximum character length: 1 Permissible values: Value Meaning 1 ECG monitoring 2 Echocardiography 3 Radionuclide (perfusion) imaging (e.g. Thallium, Sestamibi) 4 Positron Emission Tomography (PET) 5 Magnetic Resonance Imaging (MRI) Supplementary values: 9 Not stated/inadequately described Source and reference attributes Submitting organisation: Australian Institute of Health and Welfare Data set specification specific attributes Functional stress test cluster Conditional obligation: To be provided when a functional stress test is performed. Data element attributes Collection and usage attributes Guide for use: More than one code may be recorded (code 9 is excluded from multiple coding). Source and reference attributes Submitting organisation: Acute coronary syndrome data working group Relational attributes Related metadata references: Supersedes Person—functional stress test element, code N Health, Superseded 01/10/2008 Implementation in Data Set Specifications: Functional stress test cluster Health, Standard 01/10/2008

    Tipo de dados

    integer

    Functional stress test intensity
    Descrição

    Functional stress test—stress test intensity, code N Obligation: Conditional Identifying and definitional attributes Short name: Functional stress test intensity METeOR identifier: 344443 Registration status: Health, Standard 01/10/2008 Definition: The intensity of the functional stress test performed on a person, as represented by a code. Data Element Concept: Functional stress test—stress test intensity Value domain attributes Representational attributes Representation class: Code Data type: Number Format: N Maximum character length: 1 Permissible values: Value Meaning 1 Maximal (symptom limited) 2 Submaximal 3 Rest / distribution study Supplementary values: 9 Not stated/inadequately described Collection and usage attributes Guide for use: CODE 1 Maximal (symptom limited) Use this code when the intensity of the stress test is to increase the person's heart rate with the exercise to 85-90% of their predicted maximum heart rate. CODE 2 Submaximal Use this code when the intensity of the stress test is limited to increasing the person's heart rate with the exercise to 120 beats per minute or 70% of their predicted maximum heart rate. CODE 3 Rest/distribution study Use this code when a Thallium (nuclear) study has been undertaken for the assessment of viability, where no exercise or pharmacologic stress component has been undertaken CODE 9 Not stated/inadequately described Not for use in primary data collections. Data set specification specific attributes Functional stress test cluster Conditional obligation: To be provided when a functional stress test is performed. Data element attributes Collection and usage attributes Collection methods: The intensity is determined and recorded by the clinicians performing the test. Comments: The stress test intensity has implications for the interpretation of the test results. Relational attributes Implementation in Data Set Specifications: Functional stress test cluster Health, Standard 01/10/2008

    Tipo de dados

    integer

    Date of functional stress test
    Descrição

    Functional stress test—test date, DDMMYYYY Obligation: Conditional Identifying and definitional attributes Short name: Date of functional stress test METeOR identifier: 347054 Registration status: Health, Standard 01/10/2008 Definition: The date when a functional stress test is performed on a person. Data Element Concept: Functional stress test—test date Value domain attributes Representational attributes Representation class: Date Data type: Date/Time Format: DDMMYYYY Maximum character length: 8 Data set specification specific attributes Functional stress test cluster Conditional obligation: To be provided when a functional stress test is performed. Data element attributes Collection and usage attributes Guide for use: The date should always be recorded when a functional stress test is performed. Relational attributes Implementation in Data Set Specifications: Functional stress test cluster Health, Standard 01/10/2008

    Tipo de dados

    date

    Person
    Descrição

    Person

    Functional stress test performed indicator
    Descrição

    Person—functional stress test performed indicator, yes/no code N Identifying and definitional attributes Short name: Functional stress test performed indicator METeOR identifier: 347697 Registration status: Health, Standard 01/10/2008 Definition: An indicator of whether a functional stress test was performed on a person, as represented by a code. Data Element Concept: Person—functional stress test performed indicator Value domain attributes Representational attributes Representation class: Code Data type: Number Format: N Maximum character length: 1 Permissible values: Value Meaning 1 Yes 2 No Supplementary values: 9 Not stated/inadequately described Collection and usage attributes Guide for use: CODE 9 Not stated/inadequately described This code is not for use in primary data collections. Data element attributes Collection and usage attributes Guide for use: Code 1 Yes Record if a functional stress test was performed. Code 2 No Record if no functional stress test was performed. Relational attributes Implementation in Data Set Specifications: Functional stress test cluster Health, Standard 01/10/2008

    Tipo de dados

    integer

    Similar models

    Acute coronary syndrome (clinical) DSS 2013- Functional stress test cluster Metadata Online Registry (METeOR)

    Name
    Tipo
    Description | Question | Decode (Coded Value)
    Tipo de dados
    Alias
    Item Group
    Functional stress test
    Item
    Functional stress test assessment of cardiac perfusion
    integer
    Code List
    Functional stress test assessment of cardiac perfusion
    CL Item
    Exercise tolerance  (1)
    CL Item
    Pharmacological (2)
    CL Item
    Not stated/inadequately described (9)
    Item
    Functional stress ischaemic and perfusion outcome result
    integer
    Code List
    Functional stress ischaemic and perfusion outcome result
    CL Item
    No abnormal outcome (1)
    CL Item
    Ischaemic discomfort and/or ST shift (2)
    CL Item
    Fixed perfusion or wall motion defects only (3)
    CL Item
    Reversible perfusion or wall motion defects only (4)
    CL Item
    Fixed and reversible perfusion and wall motion defects (5)
    CL Item
    Equivocal (6)
    CL Item
    Not stated/inadequately described (9)
    Item
    Functional stress test element
    integer
    Code List
    Functional stress test element
    CL Item
    ECG monitoring (1)
    CL Item
    Echocardiography (2)
    CL Item
    Radionuclide (perfusion) imaging (e.g. Thallium, Sestamibi) (3)
    CL Item
    Positron Emission Tomography (PET) (4)
    CL Item
    Magnetic Resonance Imaging (MRI) (5)
    CL Item
    Not stated/inadequately described (9)
    Item
    Functional stress test intensity
    integer
    Code List
    Functional stress test intensity
    CL Item
    Maximal (symptom limited) (1)
    CL Item
    Submaximal  (2)
    CL Item
    Rest / distribution study (3)
    CL Item
    Not stated/inadequately described (9)
    Test date
    Item
    Date of functional stress test
    date
    Item Group
    Person
    Item
    Functional stress test performed indicator
    integer
    Code List
    Functional stress test performed indicator
    CL Item
    Yes (1)
    CL Item
    No (2)
    CL Item
    Not stated/inadequately described (9)

    Do you need help on how to use the search function? Please watch the corresponding tutorial video for more details and learn how to use the search function most efficiently.