This protocol provides instructions for drawing, processing, and storing blood for the serum creatinine assay according to the National Health and Nutrition Examination Survey (NHANES) methods. Creatinine concentration in a participant’s serum is measured according to the Jaffe rate method. ODM derived from: https://cde.nlm.nih.gov Primary source: https://www.phenxtoolkit.org/ Recent publication: Hendershot, T., Pan, H., Haines, J., Harlan, W.R., Marazita, M.L., McCarty, C.A., Ramos, E.M., and Hamilton, C.M. (2015) Using the PhenX toolkit to add standard measures to a study. Curr. Protoc. Hum. Genet. 86:1.21.1-1.21.17. doi: 10.1002/0471142905.hg0121s86 Permission to publish granted by Carol M. Hamilton.

Link

https://cde.nlm.nih.gov

Trefwoorden

  1. 26-04-16 26-04-16 -
Geüploaded op

26 april 2016

DOI

Voor een aanvraag inloggen.

Licentie

Creative Commons BY-NC 3.0

Model Commentaren :

Hier kunt u commentaar leveren op het model. U kunt de tekstballonnen bij de itemgroepen en items gebruiken om er specifiek commentaar op te geven.

Itemgroep Commentaren voor :

Item Commentaren voor :

U moet ingelogd zijn om formulieren te downloaden. AUB inloggen of schrijf u gratis in.

Serum Creatinine Assay Protocol PhenX Toolkit

Serum Creatinine Assay Protocol PhenX Toolkit

PhenX - serum creatinine assay for kidney function protocol
Beschrijving

PhenX - serum creatinine assay for kidney function protocol

Alias
UMLS CUI-1
C3171775
Do you have hemophilia?
Beschrijving

hemophilia

Datatype

integer

Alias
UMLS CUI [1]
C0684275
Have you received cancer chemotherapy in the past four weeks or do you anticipate such therapy in the next four weeks?
Beschrijving

chemotherapy

Datatype

integer

Alias
UMLS CUI [1]
C0392920
UMLS CUI [2,1]
C0392920
UMLS CUI [2,2]
C1301732
Exclusion Criteria
Beschrijving

exclusion criteria

Datatype

integer

Alias
UMLS CUI [1]
C0680251
Was blood drawn?
Beschrijving

blood drawn done

Datatype

boolean

Alias
UMLS CUI [1]
C3166519
Was full sample obtained?
Beschrijving

blood draw sample

Datatype

boolean

Alias
UMLS CUI [1]
C3166525
Service comment: Record any comments about the blood draw, including any reasons for the tube not being drawn according to the protocol.
Beschrijving

service comment

Datatype

text

Alias
UMLS CUI [1]
C0485795
Service comment: Record any comments about the sample during processing.
Beschrijving

service comment

Datatype

text

Alias
UMLS CUI [1]
C0485795
Repeatability of the assay
Beschrijving

assay repeatability

Datatype

float

Alias
UMLS CUI [1]
C3166274
Coefficient of variation for the assay
Beschrijving

coefficient of variation

Datatype

integer

Alias
UMLS CUI [1]
C3176770

Similar models

Serum Creatinine Assay Protocol PhenX Toolkit

Name
Type
Description | Question | Decode (Coded Value)
Datatype
Alias
Item Group
PhenX - serum creatinine assay for kidney function protocol
C3171775 (UMLS CUI-1)
Item
Do you have hemophilia?
integer
C0684275 (UMLS CUI [1])
Code List
Do you have hemophilia?
CL Item
Yes (1)
C1705108 (UMLS CUI-1)
CL Item
No (2)
C1298908 (UMLS CUI-1)
CL Item
Refused (3)
C1705116 (UMLS CUI-1)
CL Item
Don't know (4)
C3843613 (UMLS CUI-1)
Item
Have you received cancer chemotherapy in the past four weeks or do you anticipate such therapy in the next four weeks?
integer
C0392920 (UMLS CUI [1])
C0392920 (UMLS CUI [2,1])
C1301732 (UMLS CUI [2,2])
Code List
Have you received cancer chemotherapy in the past four weeks or do you anticipate such therapy in the next four weeks?
CL Item
Yes (1)
C1705108 (UMLS CUI-1)
CL Item
No (2)
C1298908 (UMLS CUI-1)
CL Item
Refused (3)
C1705116 (UMLS CUI-1)
CL Item
Don't know (4)
C3843613 (UMLS CUI-1)
Item
Exclusion Criteria
integer
C0680251 (UMLS CUI [1])
Code List
Exclusion Criteria
CL Item
Hemophilia  (1)
C0684275 (UMLS CUI-1)
CL Item
Received cancer chemotherapy in the last 3 weeks (2)
C3842787 (UMLS CUI-1)
CL Item
None – proceed with blood draw (3)
C3842785 (UMLS CUI-1)
blood drawn done
Item
Was blood drawn?
boolean
C3166519 (UMLS CUI [1])
blood draw sample
Item
Was full sample obtained?
boolean
C3166525 (UMLS CUI [1])
service comment
Item
Service comment: Record any comments about the blood draw, including any reasons for the tube not being drawn according to the protocol.
text
C0485795 (UMLS CUI [1])
service comment
Item
Service comment: Record any comments about the sample during processing.
text
C0485795 (UMLS CUI [1])
assay repeatability
Item
Repeatability of the assay
float
C3166274 (UMLS CUI [1])
coefficient of variation
Item
Coefficient of variation for the assay
integer
C3176770 (UMLS CUI [1])