The Charité Alarm Fatigue Questionnaire (CAFQa) is a questionnaire for measuring alarm fatigue in nurses and physicians. It was developed according to the best practices of scale construction and should not take more than five minutes to fill out. It has two distinct, yet correlated scales: The alarm stress scale measures the psychophysiological effects of alarms; the alarm coping scale measures the influence of systemic variables and alarm management practices on an ICU’s alarm situation.

Länk

alarmZen

Nyckelord

  1. 2023-09-07 2023-09-07 - Dr. Christian Niklas
  2. 2023-09-07 2023-09-07 - Dr. Christian Niklas
  3. 2023-09-08 2023-09-08 - Dr. Christian Niklas
  4. 2023-10-09 2023-10-09 - Dr. Christian Niklas
Rättsinnehavare

Wunderlich, Poncette, Balzer

Uppladdad den

8 september 2023

DOI

10.1038/s41598-023-40290-7

Licens

Creative Commons BY 4.0

Modellkommentarer :

Här kan du kommentera modellen. Med hjälp av pratbubblor i Item-grupperna och Item kan du lägga in specifika kommentarer.

Itemgroup-kommentar för :

Item-kommentar för :

Du måste vara inloggad för att kunna ladda ner formulär. Var vänlig logga in eller registrera dig utan kostnad.

Charité Alarm Fatigue Questionnaire - CAFQa

Validation questionnaire

  1. StudyEvent: Charité Alarm Fatigue Questionnaire - CAFQa
    1. Validation questionnaire
Beskrivning

Record ID
Beskrivning

record_id

Datatyp

text

Alias
UMLS CUI [1,1]
C1830337
Beskrivning

1. With too many alarms on my ward, my work performance and motivation decreases.
Beskrivning

Arbeitsleistung und Motivation

Datatyp

integer

Alias
UMLS CUI [1,1]
C3873728
UMLS CUI [1,2]
C3843660
UMLS CUI [2,1]
C0558078
2. Too many alarms trigger physical symptoms for me, e.g., nervousness, headaches, sleep disturbances.
Beskrivning

körperliche Symptome

Datatyp

integer

Alias
UMLS CUI [1,1]
C1457887
UMLS CUI [2,1]
C3873728
UMLS CUI [2,2]
C3843660
3. Alarms reduce my concentration and attention.
Beskrivning

Konzentration und Aufmerksamkeit

Datatyp

integer

Alias
UMLS CUI [1,1]
C0262630
UMLS CUI [2,1]
C3873728
4. My or neighbouring patients' alarms or crisis alarms frequently interrupt my workflow.
Beskrivning

Arbeitsabläufe

Datatyp

integer

Alias
UMLS CUI [1,1]
C0443239
UMLS CUI [1,2]
C0043227
UMLS CUI [2,1]
C3873728
5. There are situations when alarms confuse me.
Beskrivning

durcheinanderbringen.

Datatyp

integer

Alias
UMLS CUI [1,1]
C0009676
UMLS CUI [2,1]
C3873728
Beskrivning

6. In my ward, a procedural instruction on how to deal with alarms is regularly updated and shared with all staff.
Beskrivning

Verfahrensanweisung

Datatyp

integer

Alias
UMLS CUI [1,1]
C4738289
UMLS CUI [1,2]
C1519814
UMLS CUI [1,3]
C0205272
UMLS CUI [2,1]
C3873728
7. Responsible personnel respond quickly and appropriately to alarms.
Beskrivning

schnell und angemessen

Datatyp

integer

Alias
UMLS CUI [1,1]
C0456962
UMLS CUI [1,2]
C0205342
UMLS CUI [1,3]
C5776756
UMLS CUI [2,1]
C3873728
8. The audible and visual monitor alarms used on my ward floor and cockpit allow me to clearly assign patient, unit, and urgency.
Beskrivning

eindeutige Zuordnung

Datatyp

integer

Alias
UMLS CUI [1,1]
C1269815
UMLS CUI [1,2]
C0332149
UMLS CUI [2,1]
C3873728
9. Alarm limits are regularly adjusted based on patients' clinical symptoms (e.g., blood pressure limits for condition after bypass surgery).
Beskrivning

Alarmgrenzen Symptome

Datatyp

integer

Alias
UMLS CUI [1,1]
C4068518
UMLS CUI [1,2]
C0456081
UMLS CUI [1,3]
C1457887

Similar models

Validation questionnaire

  1. StudyEvent: Charité Alarm Fatigue Questionnaire - CAFQa
    1. Validation questionnaire
Name
Typ
Description | Question | Decode (Coded Value)
Datatyp
Alias
Item Group
record_id
Item
Record ID
text
C1830337 (UMLS CUI [1,1])
Item Group
Item
1. With too many alarms on my ward, my work performance and motivation decreases.
integer
C3873728 (UMLS CUI [1,1])
C3843660 (UMLS CUI [1,2])
C0558078 (UMLS CUI [2,1])
Code List
1. With too many alarms on my ward, my work performance and motivation decreases.
CL Item
I do not agree at all (4)
C0451267 (UMLS CUI [1,1])
CL Item
I do not agree (3)
C0451267 (UMLS CUI [1,1])
CL Item
I agree in part (2)
C0451267 (UMLS CUI [1,1])
CL Item
I agree (1)
C0451267 (UMLS CUI [1,1])
CL Item
I very much agree (0)
C0451267 (UMLS CUI [1,1])
Item
2. Too many alarms trigger physical symptoms for me, e.g., nervousness, headaches, sleep disturbances.
integer
C1457887 (UMLS CUI [1,1])
C3873728 (UMLS CUI [2,1])
C3843660 (UMLS CUI [2,2])
Code List
2. Too many alarms trigger physical symptoms for me, e.g., nervousness, headaches, sleep disturbances.
CL Item
I do not agree at all (4)
C0451267 (UMLS CUI [1,1])
CL Item
I do not agree (3)
C0451267 (UMLS CUI [1,1])
CL Item
I agree in part (2)
C0451267 (UMLS CUI [1,1])
CL Item
I agree (1)
C0451267 (UMLS CUI [1,1])
CL Item
I very much agree (0)
C0451267 (UMLS CUI [1,1])
Item
3. Alarms reduce my concentration and attention.
integer
C0262630 (UMLS CUI [1,1])
C3873728 (UMLS CUI [2,1])
Code List
3. Alarms reduce my concentration and attention.
CL Item
I do not agree at all (4)
C0451267 (UMLS CUI [1,1])
CL Item
I do not agree (3)
C0451267 (UMLS CUI [1,1])
CL Item
I agree in part (2)
C0451267 (UMLS CUI [1,1])
CL Item
I agree (1)
C0451267 (UMLS CUI [1,1])
CL Item
I very much agree (0)
C0451267 (UMLS CUI [1,1])
Item
4. My or neighbouring patients' alarms or crisis alarms frequently interrupt my workflow.
integer
C0443239 (UMLS CUI [1,1])
C0043227 (UMLS CUI [1,2])
C3873728 (UMLS CUI [2,1])
Code List
4. My or neighbouring patients' alarms or crisis alarms frequently interrupt my workflow.
CL Item
I do not agree at all (4)
C0451267 (UMLS CUI [1,1])
CL Item
I do not agree (3)
C0451267 (UMLS CUI [1,1])
CL Item
I agree in part (2)
C0451267 (UMLS CUI [1,1])
CL Item
I agree (1)
C0451267 (UMLS CUI [1,1])
CL Item
I very much agree (0)
C0451267 (UMLS CUI [1,1])
Item
5. There are situations when alarms confuse me.
integer
C0009676 (UMLS CUI [1,1])
C3873728 (UMLS CUI [2,1])
Code List
5. There are situations when alarms confuse me.
CL Item
I do not agree at all (4)
C0451267 (UMLS CUI [1,1])
CL Item
I do not agree (3)
C0451267 (UMLS CUI [1,1])
CL Item
I agree in part (2)
C0451267 (UMLS CUI [1,1])
CL Item
I agree (1)
C0451267 (UMLS CUI [1,1])
CL Item
I very much agree (0)
C0451267 (UMLS CUI [1,1])
Item Group
Item
6. In my ward, a procedural instruction on how to deal with alarms is regularly updated and shared with all staff.
integer
C4738289 (UMLS CUI [1,1])
C1519814 (UMLS CUI [1,2])
C0205272 (UMLS CUI [1,3])
C3873728 (UMLS CUI [2,1])
Code List
6. In my ward, a procedural instruction on how to deal with alarms is regularly updated and shared with all staff.
CL Item
I do not agree at all (0)
C0451267 (UMLS CUI [1,1])
CL Item
I do not agree (1)
C0451267 (UMLS CUI [1,1])
CL Item
I agree in part (2)
CL Item
I agree (3)
C0451267 (UMLS CUI [1,1])
CL Item
I very much agree (4)
Item
7. Responsible personnel respond quickly and appropriately to alarms.
integer
C0456962 (UMLS CUI [1,1])
C0205342 (UMLS CUI [1,2])
C5776756 (UMLS CUI [1,3])
C3873728 (UMLS CUI [2,1])
Code List
7. Responsible personnel respond quickly and appropriately to alarms.
CL Item
I do not agree at all (0)
C0451267 (UMLS CUI [1,1])
CL Item
I do not agree (1)
C0451267 (UMLS CUI [1,1])
CL Item
I agree in part (2)
CL Item
I agree (3)
C0451267 (UMLS CUI [1,1])
CL Item
I very much agree (4)
Item
8. The audible and visual monitor alarms used on my ward floor and cockpit allow me to clearly assign patient, unit, and urgency.
integer
C1269815 (UMLS CUI [1,1])
C0332149 (UMLS CUI [1,2])
C3873728 (UMLS CUI [2,1])
Code List
8. The audible and visual monitor alarms used on my ward floor and cockpit allow me to clearly assign patient, unit, and urgency.
CL Item
I do not agree at all (0)
C0451267 (UMLS CUI [1,1])
CL Item
I do not agree (1)
C0451267 (UMLS CUI [1,1])
CL Item
I agree in part (2)
CL Item
I agree (3)
C0451267 (UMLS CUI [1,1])
CL Item
I very much agree (4)
Item
9. Alarm limits are regularly adjusted based on patients' clinical symptoms (e.g., blood pressure limits for condition after bypass surgery).
integer
C4068518 (UMLS CUI [1,1])
C0456081 (UMLS CUI [1,2])
C1457887 (UMLS CUI [1,3])
Code List
9. Alarm limits are regularly adjusted based on patients' clinical symptoms (e.g., blood pressure limits for condition after bypass surgery).
CL Item
I do not agree at all (0)
C0451267 (UMLS CUI [1,1])
CL Item
I do not agree (1)
C0451267 (UMLS CUI [1,1])
CL Item
I agree in part (2)
CL Item
I agree (3)
C0451267 (UMLS CUI [1,1])
CL Item
I very much agree (4)

Använd detta formulär för feedback, frågor och förslag på förbättringar.

Fält markerade med * är obligatoriska.

Do you need help on how to use the search function? Please watch the corresponding tutorial video for more details and learn how to use the search function most efficiently.

Watch Tutorial