ID

41353

Description

Metadata definitions for the Smart Device System for Movement Disorders. Clinical Protocol and Registration Information available on: https://clinicaltrials.gov/ct2/show/NCT03638479 Principal Investigator: Julian Varghese Description for Assessment Steps for Neurologic Examination are available under: Varghese J, Niewöhner S, Soto-Rey I, et al. A Smart Device System to Identify New Phenotypical Characteristics in Movement Disorders. Front Neurol. 2019;10:48. doi:10.3389/fneur.2019.00048

Link

https://clinicaltrials.gov/ct2/show/NCT03638479

Keywords

  1. 1/31/20 1/31/20 - Julian Varghese
  2. 2/4/20 2/4/20 - Julian Varghese
  3. 2/4/20 2/4/20 - Julian Varghese
  4. 9/3/20 9/3/20 - Julian Varghese
Copyright Holder

Julian Varghese

Uploaded on

September 3, 2020

DOI

To request one please log in.

License

Creative Commons BY-NC 4.0

Model comments :

You can comment on the data model here. Via the speech bubbles at the itemgroups and items you can add comments to those specificially.

Itemgroup comments for :

Item comments for :

In order to download data models you must be logged in. Please log in or register for free.

Smart Device System Meta Data Definitions

Neurologic Examination

Neurologic examination
Description

Neurologic examination

Alias
UMLS CUI-1
C0027853
Timeseries gravitation raw data (left + right hand)
Description

Measured via smartwatch (Apple series >= 4) in all three axes for all assessment steps according to protocol. Sampling rate 100 Hz. Unit measured: Gravitational Force (g) per each 10 milliseconds.

Data type

text

Measurement units
  • g each 10 ms
Alias
UMLS CUI [1,1]
C0018216
UMLS CUI [1,2]
C1511726
g each 10 ms
Timeseries rotation raw data (left + right hand)
Description

Measured via smartwatch (Apple series >= 4) in all three axes. Sampling rate 100 Hz. For all assessment steps according to protocol. Sampling rate 100 Hz. Unit measured: °(degree of rotation) per each 10 milliseconds.

Data type

text

Measurement units
  • g each 10 ms
Alias
UMLS CUI [1,1]
C0035868
UMLS CUI [1,2]
C1511726
g each 10 ms
Timeseries acceleration raw data (left + right hand)
Description

Measured via smartwatch (Apple series >= 4) in all three axes. Sampling rate 100 Hz. Gravitational components are removed. For all assessment steps according to protocol. Sampling rate 100 Hz. Unit measured: Gravitational Force (g) per each 10 milliseconds.

Data type

text

Measurement units
  • g each 10 ms
Alias
UMLS CUI [1,1]
C0000894
UMLS CUI [1,2]
C1511726
g each 10 ms
Timeseries spiral drawing (left + right hand)
Description

Measured via tablet (Apple iPad Pro >= 2018): X,Y points and pencil pressure force. Spirals drawn with both Hands. Sample rate 240 Hz. Force = 1.0 corresponds to average stylus touch: https://developer.apple.com/documentation/uikit/uitouch/1618110-force

Data type

text

Measurement units
  • x, y, force each 4,16 ms
Alias
UMLS CUI [1,1]
C0522554
UMLS CUI [1,2]
C1511726
x, y, force each 4,16 ms
Finger-Tapping: Number of Hits (left + right hand)
Description

Measured on iPad Pro (version >=2018). Number of hits within 15 seconds.

Data type

integer

Alias
UMLS CUI [1,1]
C0870564
UMLS CUI [1,2]
C1511726
Timeseries voice and speach raw data
Description

Measured via iPhone built-in mic (version >= series 7). Sample with 44.1 kHz.

Data type

text

Alias
UMLS CUI [1,1]
C0042939
UMLS CUI [1,2]
C0936012
UMLS CUI [1,3]
C1511726

Similar models

Neurologic Examination

Name
Type
Description | Question | Decode (Coded Value)
Data type
Alias
Item Group
Neurologic examination
C0027853 (UMLS CUI-1)
Gravitation raw data
Item
Timeseries gravitation raw data (left + right hand)
text
C0018216 (UMLS CUI [1,1])
C1511726 (UMLS CUI [1,2])
Rotation raw data
Item
Timeseries rotation raw data (left + right hand)
text
C0035868 (UMLS CUI [1,1])
C1511726 (UMLS CUI [1,2])
Acceleration raw data
Item
Timeseries acceleration raw data (left + right hand)
text
C0000894 (UMLS CUI [1,1])
C1511726 (UMLS CUI [1,2])
Spiral drawing raw data
Item
Timeseries spiral drawing (left + right hand)
text
C0522554 (UMLS CUI [1,1])
C1511726 (UMLS CUI [1,2])
Finger-Tapping
Item
Finger-Tapping: Number of Hits (left + right hand)
integer
C0870564 (UMLS CUI [1,1])
C1511726 (UMLS CUI [1,2])
Voice analysis raw data
Item
Timeseries voice and speach raw data
text
C0042939 (UMLS CUI [1,1])
C0936012 (UMLS CUI [1,2])
C1511726 (UMLS CUI [1,3])

Please use this form for feedback, questions and suggestions for improvements.

Fields marked with * are required.

Do you need help on how to use the search function? Please watch the corresponding tutorial video for more details and learn how to use the search function most efficiently.