ID

33998

Beschreibung

Study ID: 102936 Clinical Study ID: HZA102936 Study Title:A randomised, placebo-controlled, four-way crossover repeat dose study to evaluate the effect of the inhaled fluticasone furoate (FF)/GW642444M combination on electrocardiographic parameters, with moxifloxacin as a positive control, in healthy subjects Patient Level Data: Study Listed on ClinicalStudyDataRequest.com Clinicaltrials.gov Identifier: NCT01209026 https://clinicaltrials.gov/ct2/show/NCT01209026?term=NCT01209026 Sponsor: GlaxoSmithKline Collaborators: N/A Phase: Phase 1 Study Recruitment Status: Completed Generic Name: fluticasone furoate Trade Name: Allermist,Veramyst,Avamys; Veramyst,Avamys,Allermist Study Indication: Asthma The study consists of a screening, 4 treatment periods and a follow up. Treatment periods 1-4 are each 7 days long. Treatment period 1 Days 1-6 (TP1D-D6) Treatment period 1 Day 7 (TP1D7) Treatment period 2 Days 1-6 (TP2D1-D6) Treatment period 2 Day 7 (TP2D7) Treatment period 3 Days 1-6 (TP3D1-D6) Treatment period 3 Day 7 (TP3D7) Treatment period 4 Days 1-6 (TP4D1-D6) Treatment period 4 Day 7 (TP4D7) This document contains the IP Device Malfunction (IPDEVMAL) form. It has to be filled in for repeat if required.

Link

https://clinicaltrials.gov/ct2/show/NCT01209026?term=NCT01209026

Stichworte

  1. 09.01.19 09.01.19 -
  2. 10.01.19 10.01.19 - Sarah Riepenhausen
Rechteinhaber

GlaxoSmithKline

Hochgeladen am

10. Januar 2019

DOI

Für eine Beantragung loggen Sie sich ein.

Lizenz

Creative Commons BY-NC 3.0

Modell Kommentare :

Hier können Sie das Modell kommentieren. Über die Sprechblasen an den Itemgruppen und Items können Sie diese spezifisch kommentieren.

Itemgroup Kommentare für :

Item Kommentare für :

Um Formulare herunterzuladen müssen Sie angemeldet sein. Bitte loggen Sie sich ein oder registrieren Sie sich kostenlos.

Effect of inhaled fluticasone furoate/Vilanterol combination on electrocardiographic parameters in healthy subjects, NCT01209026

IP Device Malfunction (IPDEVMAL)

Administrative data
Beschreibung

Administrative data

Alias
UMLS CUI-1
C1320722
Subject number
Beschreibung

Subject number

Datentyp

text

Alias
UMLS CUI [1]
C2348585
IP Device Malfunction (IPDEVMAl)
Beschreibung

IP Device Malfunction (IPDEVMAl)

Alias
UMLS CUI-1
C1881681
lnvestigational product container number
Beschreibung

lnvestigational product container number

Datentyp

integer

Alias
UMLS CUI [1,1]
C0304229
UMLS CUI [1,2]
C0180098
UMLS CUI [1,3]
C0600091
Reasons for device malfunction
Beschreibung

Reasons for device malfunction

Alias
UMLS CUI-1
C1881681
UMLS CUI-2
C0566251
Mouthpiece Cover does not stay at the fully actuated position
Beschreibung

Mouthpiece Cover, position

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0725867
UMLS CUI [1,2]
C3888055
UMLS CUI [1,3]
C1550045
Mouthpiece Cover came apart from the mechanism
Beschreibung

Mouthpiece cover detached

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0725867
UMLS CUI [1,2]
C3888055
UMLS CUI [1,3]
C0687118
Inhaler is cracked or broken apart
Beschreibung

Inhaler cracked or broken apart

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0021461
UMLS CUI [1,2]
C1706353
Difficult to open mouthpiece cover/ force to actuate was too high
Beschreibung

Difficult to open mouthpiece cover

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0725867
UMLS CUI [1,2]
C3888055
UMLS CUI [1,3]
C0332218
UMLS CUI [1,4]
C0175566
Difficult to close mouthpiece cover
Beschreibung

Difficult to close mouthpiece cover

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0725867
UMLS CUI [1,2]
C3888055
UMLS CUI [1,3]
C0332218
UMLS CUI [1,4]
C3810854
Powder fell lost prior to use
Beschreibung

Powder fell lost prior to use

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0991575
UMLS CUI [1,2]
C0745777
No powder came out (Emission substance)
Beschreibung

No powder came out (Emission substance)

Datentyp

boolean

Alias
UMLS CUI [1,1]
C1298908
UMLS CUI [1,2]
C0991575
UMLS CUI [1,3]
C2349995
No Device squeaks in operation
Beschreibung

No Device squeaks in operation

Datentyp

boolean

Alias
UMLS CUI [1,1]
C1298908
UMLS CUI [1,2]
C0699733
UMLS CUI [1,3]
C0028263
Device rattles in operation
Beschreibung

Device rattles in operation

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0699733
UMLS CUI [1,2]
C0028263
Dose counter did not count
Beschreibung

Dose counter did not count

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0178602
UMLS CUI [1,2]
C0750480
Dose counter is ambiguous
Beschreibung

Dose counter is ambiguous

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0178602
UMLS CUI [1,2]
C0750480
UMLS CUI [1,3]
C0332241
Dose counter overcounted
Beschreibung

Dose counter overcounted

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0178602
UMLS CUI [1,2]
C0750480
UMLS CUI [1,3]
C0439093
Dose counter undercounted
Beschreibung

Dose counter undercounted

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0178602
UMLS CUI [1,2]
C0750480
UMLS CUI [1,3]
C0439092
Difficult to pull air through the device as described in the leaflet
Beschreibung

Difficult to pull air through the device

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0332218
UMLS CUI [1,2]
C3536832
UMLS CUI [1,3]
C0699733
Device smelt/bad odour when pack opened
Beschreibung

Device smelt/bad odour when pack opened

Datentyp

boolean

Alias
UMLS CUI [1,1]
C0699733
UMLS CUI [1,2]
C0037361
Other reasons
Beschreibung

Other reasons

Datentyp

boolean

Alias
UMLS CUI [1]
C3840932
If other reason, please specify
Beschreibung

Other reason specification

Datentyp

text

Alias
UMLS CUI [1]
C3840932

Ähnliche Modelle

IP Device Malfunction (IPDEVMAL)

Name
Typ
Description | Question | Decode (Coded Value)
Datentyp
Alias
Item Group
Administrative data
C1320722 (UMLS CUI-1)
Subject number
Item
Subject number
text
C2348585 (UMLS CUI [1])
Item Group
IP Device Malfunction (IPDEVMAl)
C1881681 (UMLS CUI-1)
lnvestigational product container number
Item
lnvestigational product container number
integer
C0304229 (UMLS CUI [1,1])
C0180098 (UMLS CUI [1,2])
C0600091 (UMLS CUI [1,3])
Item Group
Reasons for device malfunction
C1881681 (UMLS CUI-1)
C0566251 (UMLS CUI-2)
Mouthpiece Cover, position
Item
Mouthpiece Cover does not stay at the fully actuated position
boolean
C0725867 (UMLS CUI [1,1])
C3888055 (UMLS CUI [1,2])
C1550045 (UMLS CUI [1,3])
Mouthpiece cover detached
Item
Mouthpiece Cover came apart from the mechanism
boolean
C0725867 (UMLS CUI [1,1])
C3888055 (UMLS CUI [1,2])
C0687118 (UMLS CUI [1,3])
Inhaler cracked or broken apart
Item
Inhaler is cracked or broken apart
boolean
C0021461 (UMLS CUI [1,1])
C1706353 (UMLS CUI [1,2])
Difficult to open mouthpiece cover
Item
Difficult to open mouthpiece cover/ force to actuate was too high
boolean
C0725867 (UMLS CUI [1,1])
C3888055 (UMLS CUI [1,2])
C0332218 (UMLS CUI [1,3])
C0175566 (UMLS CUI [1,4])
Difficult to close mouthpiece cover
Item
Difficult to close mouthpiece cover
boolean
C0725867 (UMLS CUI [1,1])
C3888055 (UMLS CUI [1,2])
C0332218 (UMLS CUI [1,3])
C3810854 (UMLS CUI [1,4])
Powder fell lost prior to use
Item
Powder fell lost prior to use
boolean
C0991575 (UMLS CUI [1,1])
C0745777 (UMLS CUI [1,2])
No powder came out (Emission substance)
Item
No powder came out (Emission substance)
boolean
C1298908 (UMLS CUI [1,1])
C0991575 (UMLS CUI [1,2])
C2349995 (UMLS CUI [1,3])
No Device squeaks in operation
Item
No Device squeaks in operation
boolean
C1298908 (UMLS CUI [1,1])
C0699733 (UMLS CUI [1,2])
C0028263 (UMLS CUI [1,3])
Device rattles in operation
Item
Device rattles in operation
boolean
C0699733 (UMLS CUI [1,1])
C0028263 (UMLS CUI [1,2])
Dose counter did not count
Item
Dose counter did not count
boolean
C0178602 (UMLS CUI [1,1])
C0750480 (UMLS CUI [1,2])
Dose counter is ambiguous
Item
Dose counter is ambiguous
boolean
C0178602 (UMLS CUI [1,1])
C0750480 (UMLS CUI [1,2])
C0332241 (UMLS CUI [1,3])
Dose counter overcounted
Item
Dose counter overcounted
boolean
C0178602 (UMLS CUI [1,1])
C0750480 (UMLS CUI [1,2])
C0439093 (UMLS CUI [1,3])
Dose counter undercounted
Item
Dose counter undercounted
boolean
C0178602 (UMLS CUI [1,1])
C0750480 (UMLS CUI [1,2])
C0439092 (UMLS CUI [1,3])
Difficult to pull air through the device
Item
Difficult to pull air through the device as described in the leaflet
boolean
C0332218 (UMLS CUI [1,1])
C3536832 (UMLS CUI [1,2])
C0699733 (UMLS CUI [1,3])
Device smelt/bad odour when pack opened
Item
Device smelt/bad odour when pack opened
boolean
C0699733 (UMLS CUI [1,1])
C0037361 (UMLS CUI [1,2])
Other reasons
Item
Other reasons
boolean
C3840932 (UMLS CUI [1])
Other reason specification
Item
If other reason, please specify
text
C3840932 (UMLS CUI [1])

Benutzen Sie dieses Formular für Rückmeldungen, Fragen und Verbesserungsvorschläge.

Mit * gekennzeichnete Felder sind notwendig.

Benötigen Sie Hilfe bei der Suche? Um mehr Details zu erfahren und die Suche effektiver nutzen zu können schauen Sie sich doch das entsprechende Video auf unserer Tutorial Seite an.

Zum Video