ID

32504

Descrição

Study ID: 106837 Clinical Study ID: HZA106837 Study Title: A Long-Term, Randomized, Double-Blind, Parallel Group Study of Fluticasone Furoate/GW642444 Inhalation Powder Once-Daily and Fluticasone Furoate Inhalation Powder Once-Daily in Subjects with Asthma Patient Level Data: Study Listed on ClinicalStudyDataRequest.com Clinicaltrials.gov Identifier: NCT01086384 Sponsor: GlaxoSmithKline Collaborators: N/A Phase: Phase 3 Study Recruitment Status: Completed Generic Name: fluticasone furoate/vilanterol Trade Name: Relvar Study Indication: Asthma

Palavras-chave

  1. 11/5/18 11/5/18 -
  2. 12/6/18 12/6/18 -
Titular dos direitos

GSK group of companies

Transferido a

November 5, 2018

DOI

Para um pedido faça login.

Licença

Creative Commons BY-NC 3.0

Comentários do modelo :

Aqui pode comentar o modelo. Pode comentá-lo especificamente através dos balões de texto nos grupos de itens e itens.

Comentários do grupo de itens para :

Comentários do item para :

Para descarregar formulários, precisa de ter uma sessão iniciada. Por favor faça login ou registe-se gratuitamente.

A Parallel Group Study of Fluticasone Furoate/Vilanterol in Subjects with Asthma - 106837

IP Device Malfunction Data

IP Device Malfunction
Descrição

IP Device Malfunction

Investigation Product Container Number
Descrição

Complete a new form for each device that malfunctioned during the study

Tipo de dados

text

Mark all applicable reasons for this device
Descrição

Mark all applicable reasons for this device

Mouthpiece cover does not stay at the fully actuated position
Descrição

Mouthpiece cover does not stay at the fully actuated position

Tipo de dados

boolean

Mouthpiece cover came apart from the mechanism
Descrição

Mouthpiece cover came apart from the mechanism

Tipo de dados

boolean

Inhaler is cracked or broken apart
Descrição

Inhaler is cracked or broken apart

Tipo de dados

boolean

Difficult to open mouthpiece cover/force to actuate was too high
Descrição

Difficult to open mouthpiece cover/force to actuate was too high

Tipo de dados

boolean

Difficult to close mouthpiece cover
Descrição

Difficult to close mouthpiece cover

Tipo de dados

boolean

Powder fell out prior to use
Descrição

Powder fell out prior to use

Tipo de dados

boolean

No powder came out
Descrição

No powder came out

Tipo de dados

boolean

Device squeaks in operation
Descrição

Device squeaks in operation

Tipo de dados

boolean

Device rattles in operation
Descrição

Device rattles in operation

Tipo de dados

boolean

Dose counter did not count
Descrição

Dose counter did not count

Tipo de dados

boolean

Dose counter is ambiguous
Descrição

Dose counter is ambiguous

Tipo de dados

boolean

Dose counter overcounted
Descrição

Dose counter overcounted

Tipo de dados

boolean

Dose counter undercounted
Descrição

Dose counter undercounted

Tipo de dados

boolean

Difficult to pull air through the device as described in the leaflet
Descrição

Difficult to pull air through the device as described in the leaflet

Tipo de dados

boolean

Device smelt/bad odour when pack opened
Descrição

Device smelt/bad odour when pack opened

Tipo de dados

boolean

Other, specify
Descrição

Other, specify

Tipo de dados

text

Similar models

IP Device Malfunction Data

Name
Tipo
Description | Question | Decode (Coded Value)
Tipo de dados
Alias
Item Group
IP Device Malfunction
Investigation Product Container Number
Item
Investigation Product Container Number
text
Item Group
Mark all applicable reasons for this device
Mouthpiece cover does not stay at the fully actuated position
Item
Mouthpiece cover does not stay at the fully actuated position
boolean
Mouthpiece cover came apart from the mechanism
Item
Mouthpiece cover came apart from the mechanism
boolean
Inhaler is cracked or broken apart
Item
Inhaler is cracked or broken apart
boolean
Difficult to open mouthpiece cover/force to actuate was too high
Item
Difficult to open mouthpiece cover/force to actuate was too high
boolean
Difficult to close mouthpiece cover
Item
Difficult to close mouthpiece cover
boolean
Powder fell out prior to use
Item
Powder fell out prior to use
boolean
No powder came out
Item
No powder came out
boolean
Device squeaks in operation
Item
Device squeaks in operation
boolean
Device rattles in operation
Item
Device rattles in operation
boolean
Dose counter did not count
Item
Dose counter did not count
boolean
Dose counter is ambiguous
Item
Dose counter is ambiguous
boolean
Dose counter overcounted
Item
Dose counter overcounted
boolean
Dose counter undercounted
Item
Dose counter undercounted
boolean
Difficult to pull air through the device as described in the leaflet
Item
Difficult to pull air through the device as described in the leaflet
boolean
Device smelt/bad odour when pack opened
Item
Device smelt/bad odour when pack opened
boolean
Other, specify
Item
Other, specify
text

Use este formulário para feedback, perguntas e sugestões de aperfeiçoamento.

Campos marcados com * são obrigatórios.

Do you need help on how to use the search function? Please watch the corresponding tutorial video for more details and learn how to use the search function most efficiently.

Watch Tutorial