ID

31733

Description

Effects of Bosentan on Respiratory Mechanics; ODM derived from: https://clinicaltrials.gov/show/NCT00679068

Link

https://clinicaltrials.gov/show/NCT00679068

Keywords

  1. 9/24/18 9/24/18 -
Copyright Holder

See clinicaltrials.gov

Uploaded on

September 24, 2018

DOI

To request one please log in.

License

Creative Commons BY 4.0

Model comments :

You can comment on the data model here. Via the speech bubbles at the itemgroups and items you can add comments to those specificially.

Itemgroup comments for :

Item comments for :

In order to download data models you must be logged in. Please log in or register for free.

Eligibility Pulmonary Hypertension NCT00679068

Eligibility Pulmonary Hypertension NCT00679068

Inclusion Criteria
Description

Inclusion Criteria

Alias
UMLS CUI
C1512693
adult patients with world health organization (who) functional class ii-iii.
Description

Adult | WHO classification

Data type

boolean

Alias
UMLS CUI [1]
C0001675
UMLS CUI [2]
C4267671
a systemic pulse oximetry (spo2) between 70% and 90% at rest with room air and a baseline 6-minute walk distance between 150 and 450 m were required for inclusion.
Description

Pulse oximetry at rest Systemic on room air | 6-Minute Walk Test Meter Quantity

Data type

boolean

Alias
UMLS CUI [1,1]
C2143208
UMLS CUI [1,2]
C0205373
UMLS CUI [1,3]
C2709070
UMLS CUI [2,1]
C0430515
UMLS CUI [2,2]
C0475209
UMLS CUI [2,3]
C1265611
pah confirmed by cardiac catheterization as mean pulmonary arterial pressure greater or equal to25 mm hg, pulmonary capillary wedge pressure lower 15 mm hg,
Description

Pulmonary arterial hypertension Cardiac Catheterization | Mean pulmonary arterial pressure | Pulmonary Capillary Wedge Pressure

Data type

boolean

Alias
UMLS CUI [1,1]
C2973725
UMLS CUI [1,2]
C0018795
UMLS CUI [2]
C3854605
UMLS CUI [3]
C0086879
Exclusion Criteria
Description

Exclusion Criteria

Alias
UMLS CUI
C0680251
patients were excluded if they had patent ductus arteriosus (for hemodynamic assessment difficulties)
Description

Patent ductus arteriosus

Data type

boolean

Alias
UMLS CUI [1]
C0013274
complex congenital heart defect
Description

Complex congenital heart defect

Data type

boolean

Alias
UMLS CUI [1]
C3536558
left ventricular dysfunction (left ventricular ejection fraction lower 40%)
Description

Ventricular Dysfunction, Left | Left ventricular ejection fraction

Data type

boolean

Alias
UMLS CUI [1]
C0242698
UMLS CUI [2]
C0428772
restrictive lung disease (total lung capacity lower 70% predicted)
Description

Restrictive lung disease | Percent Predicted Total Lung Capacity

Data type

boolean

Alias
UMLS CUI [1]
C0085581
UMLS CUI [2]
C3828589
obstructive lung disease (forced expiratory volume in 1 second [fev1] lower 70% predicted
Description

Lung Diseases, Obstructive | Percent predicted FEV1

Data type

boolean

Alias
UMLS CUI [1]
C0600260
UMLS CUI [2]
C0730561
with fev1/forced vital capacity lower 60%)
Description

FEV1/FVC percent

Data type

boolean

Alias
UMLS CUI [1]
C0730560
or previously diagnosed coronary artery disease.
Description

Coronary Artery Disease

Data type

boolean

Alias
UMLS CUI [1]
C1956346

Similar models

Eligibility Pulmonary Hypertension NCT00679068

Name
Type
Description | Question | Decode (Coded Value)
Data type
Alias
Item Group
C1512693 (UMLS CUI)
Adult | WHO classification
Item
adult patients with world health organization (who) functional class ii-iii.
boolean
C0001675 (UMLS CUI [1])
C4267671 (UMLS CUI [2])
Pulse oximetry at rest Systemic on room air | 6-Minute Walk Test Meter Quantity
Item
a systemic pulse oximetry (spo2) between 70% and 90% at rest with room air and a baseline 6-minute walk distance between 150 and 450 m were required for inclusion.
boolean
C2143208 (UMLS CUI [1,1])
C0205373 (UMLS CUI [1,2])
C2709070 (UMLS CUI [1,3])
C0430515 (UMLS CUI [2,1])
C0475209 (UMLS CUI [2,2])
C1265611 (UMLS CUI [2,3])
Pulmonary arterial hypertension Cardiac Catheterization | Mean pulmonary arterial pressure | Pulmonary Capillary Wedge Pressure
Item
pah confirmed by cardiac catheterization as mean pulmonary arterial pressure greater or equal to25 mm hg, pulmonary capillary wedge pressure lower 15 mm hg,
boolean
C2973725 (UMLS CUI [1,1])
C0018795 (UMLS CUI [1,2])
C3854605 (UMLS CUI [2])
C0086879 (UMLS CUI [3])
Item Group
C0680251 (UMLS CUI)
Patent ductus arteriosus
Item
patients were excluded if they had patent ductus arteriosus (for hemodynamic assessment difficulties)
boolean
C0013274 (UMLS CUI [1])
Complex congenital heart defect
Item
complex congenital heart defect
boolean
C3536558 (UMLS CUI [1])
Ventricular Dysfunction, Left | Left ventricular ejection fraction
Item
left ventricular dysfunction (left ventricular ejection fraction lower 40%)
boolean
C0242698 (UMLS CUI [1])
C0428772 (UMLS CUI [2])
Restrictive lung disease | Percent Predicted Total Lung Capacity
Item
restrictive lung disease (total lung capacity lower 70% predicted)
boolean
C0085581 (UMLS CUI [1])
C3828589 (UMLS CUI [2])
Lung Diseases, Obstructive | Percent predicted FEV1
Item
obstructive lung disease (forced expiratory volume in 1 second [fev1] lower 70% predicted
boolean
C0600260 (UMLS CUI [1])
C0730561 (UMLS CUI [2])
FEV1/FVC percent
Item
with fev1/forced vital capacity lower 60%)
boolean
C0730560 (UMLS CUI [1])
Coronary Artery Disease
Item
or previously diagnosed coronary artery disease.
boolean
C1956346 (UMLS CUI [1])

Please use this form for feedback, questions and suggestions for improvements.

Fields marked with * are required.

Do you need help on how to use the search function? Please watch the corresponding tutorial video for more details and learn how to use the search function most efficiently.

Watch Tutorial