http://openehr.org/ckm/ Used to record indirect blood gas measurement, currently by non-invasive techniques. New indirect blood gas measurements should be added to this archetype. Where the recording device also provides another type of measurement, such as pulse rate, this should be recorded in a separate archetype, appropriate for that particular measurement to allow consistent querying. In this example, record the pulse rate in the OBSERVATION.pulse archetype. The aim is to consistently model a clinical concept, rather than to model device output; devices are increasingly multi-functional and provide overlapping measurements which may need to be recorded using a number of discrete archetypes. Waveforms should be recorded here when used to document quality of the blood gas measurement. In contrast, if used for primary diagnostic purposes e.g. of cardiac output, plesmythography should be recorded in the key associated clinical archetype - OBSERVATION.pulse.

Link

http://openehr.org/ckm/

Trefwoorden

  1. 10-04-18 10-04-18 - Halim Ugurlu
Houder van rechten

openEHR Foundation

Geüploaded op

10 april 2018

DOI

Voor een aanvraag inloggen.

Licentie

Creative Commons BY-NC 3.0

Model Commentaren :

Hier kunt u commentaar leveren op het model. U kunt de tekstballonnen bij de itemgroepen en items gebruiken om er specifiek commentaar op te geven.

Itemgroep Commentaren voor :

Item Commentaren voor :

U moet ingelogd zijn om formulieren te downloaden. AUB inloggen of schrijf u gratis in.

openEHR-EHR-OBSERVATION.indirect_oximetry.v0

openEHR-EHR-OBSERVATION.indirect_oximetry.v0

  1. StudyEvent: openEHR-EHR-OBSERVATION.indirect_oximetry.v0
    1. openEHR-EHR-OBSERVATION.indirect_oximetry.v0
openEHR-EHR-OBSERVATION.indirect_oximetry.v0.xml
Beschrijving

openEHR-EHR-OBSERVATION.indirect_oximetry.v0.xml

Alias
UMLS CUI-1
C0034108
UMLS CUI-2
C0205303
Indirect oximetry
Beschrijving

Indirect oximetry

Datatype

text

Alias
UMLS CUI [1,1]
C0034108
UMLS CUI [1,2]
C0205303
Любое событие
Beschrijving

Сроки события

Datatype

text

Alias
UMLS CUI [1]
C0441471
SpO2
Beschrijving

Насыщение кислородом периферической крови, измеренное с помощью пульсовой оксиметрии.

Datatype

text

Alias
UMLS CUI [1]
C0428179
Положение датчика
Beschrijving

Месторасположение измерительного датчика.

Datatype

text

Alias
UMLS CUI [1,1]
C1515974
UMLS CUI [1,2]
C0183210
Inspired oxygen
Beschrijving

Inspired oxygen

Datatype

text

Alias
UMLS CUI [1,1]
C0428167
UMLS CUI [1,2]
C1960999
Искажающие факторы
Beschrijving

Комментирование и запись других случайных факторов, которые могут влиять на интерпретацию наблюдений. Например, движение, боль, плохая перфузия, грудное вскармливание.

Datatype

text

Alias
UMLS CUI [1,1]
C0009673
UMLS CUI [1,2]
C0008972
Устройство
Beschrijving

Информация об используемом неинвазивном оксиметрическом устройстве.

Datatype

text

Alias
UMLS CUI [1,1]
C0034108
UMLS CUI [1,2]
C0699733
Мультимедийное изображение
Beschrijving

Информация о серии оксиметрических считываний, кроме осциллограмм, выраженная в виде мультимедийного изображения или серии изображений. Графические изображения волн должны быть записаны с помощью слота волнового сигнала и связаны архетипом типа кластер.

Datatype

text

Alias
UMLS CUI [1,1]
C0376478
UMLS CUI [1,2]
C1301725
Тип датчика
Beschrijving

Тип используемого измерительного датчика, например, передающий, отражающий, зажим или полоса, электрод.

Datatype

text

Alias
UMLS CUI [1]
C0183210
Нагрузка
Beschrijving

Информация о физической деятельности, осуществляемой во время измерения.

Datatype

text

Alias
UMLS CUI [1,1]
C0031807
UMLS CUI [1,2]
C0347984
UMLS CUI [1,3]
C0242485
Комментарий
Beschrijving

Текстовый комментарий о результатах непрямой оксиметрии.

Datatype

text

Alias
UMLS CUI [1,1]
C0947611
UMLS CUI [1,2]
C0034108
UMLS CUI [1,3]
C0205303
X - Electrode operating temperature
Beschrijving

X - Electrode operating temperature

Datatype

float

Alias
UMLS CUI [1,1]
C0039476
UMLS CUI [1,2]
C0347984
UMLS CUI [1,3]
C0242485
X - Time of sensor application
Beschrijving

X - Time of sensor application

Datatype

datetime

Alias
UMLS CUI [1,1]
C0011008
UMLS CUI [1,2]
C0185125
X - ptcO2
Beschrijving

X - ptcO2

Datatype

float

Alias
UMLS CUI [1]
C0033990
X - ptcCO2
Beschrijving

X - ptcCO2

Datatype

float

Alias
UMLS CUI [1,1]
C0391839
UMLS CUI [1,2]
C0694643
spOC
Beschrijving

Содержание кислорода в периферической крови, измеренное с помощью пульсовой СО-оксиметрии.

Datatype

float

Alias
UMLS CUI [1,1]
C0034108
UMLS CUI [1,2]
C1291013
spCO
Beschrijving

Насыщение карбоксигемоглобина в периферической крови, измеренное с помощью пульсовой СО-оксиметрии.

Datatype

text

Alias
UMLS CUI [1,1]
C0034108
UMLS CUI [1,2]
C0007061
spMet
Beschrijving

Насыщение метоксигемоглобина в периферической крови, измеренное с помощью пульсовой СО-оксиметрии.

Datatype

text

Alias
UMLS CUI [1,1]
C0034108
UMLS CUI [1,2]
C0025635
Осциллограмма
Beschrijving

Графическое изображение волны, связанное с оксиметрическим измерением.

Datatype

text

Alias
UMLS CUI [1,1]
C0034108
UMLS CUI [1,2]
C1262059
Interpretation
Beschrijving

Interpretation

Datatype

text

Alias
UMLS CUI [1]
C4086187
Extension
Beschrijving

Extension

Datatype

text

Alias
UMLS CUI [1]
C0231448

Similar models

openEHR-EHR-OBSERVATION.indirect_oximetry.v0

  1. StudyEvent: openEHR-EHR-OBSERVATION.indirect_oximetry.v0
    1. openEHR-EHR-OBSERVATION.indirect_oximetry.v0
Name
Type
Description | Question | Decode (Coded Value)
Datatype
Alias
Item Group
C0034108 (UMLS CUI-1)
C0205303 (UMLS CUI-2)
Indirect oximetry
Item
text
C0034108 (UMLS CUI [1,1])
C0205303 (UMLS CUI [1,2])
Any event
Item
Любое событие
text
C0441471 (UMLS CUI [1])
spO2
Item
SpO2
text
C0428179 (UMLS CUI [1])
Sensor site
Item
Положение датчика
text
C1515974 (UMLS CUI [1,1])
C0183210 (UMLS CUI [1,2])
Item
text
C0428167 (UMLS CUI [1,1])
C1960999 (UMLS CUI [1,2])
Code List
Inspired oxygen
CL Item
 (Details of the amount of oxygen available to the subject at the time of observation. Assumed values of 21% oxygen concentration, Fi02 of 0.21 and oxygen flow rate of 0 l/min or 0 ml/min.)
Confounding factors
Item
Искажающие факторы
text
C0009673 (UMLS CUI [1,1])
C0008972 (UMLS CUI [1,2])
Oximetry device
Item
Устройство
text
C0034108 (UMLS CUI [1,1])
C0699733 (UMLS CUI [1,2])
Multimedia image
Item
Мультимедийное изображение
text
C0376478 (UMLS CUI [1,1])
C1301725 (UMLS CUI [1,2])
Item
Тип датчика
text
C0183210 (UMLS CUI [1])
Code List
Тип датчика
CL Item
Передающий (1)
CL Item
Отражающий (2)
CL Item
Зажим (3)
CL Item
Полоска (4)
CL Item
 (5)
Exertion
Item
Нагрузка
text
C0031807 (UMLS CUI [1,1])
C0347984 (UMLS CUI [1,2])
C0242485 (UMLS CUI [1,3])
Comment
Item
Комментарий
text
C0947611 (UMLS CUI [1,1])
C0034108 (UMLS CUI [1,2])
C0205303 (UMLS CUI [1,3])
X - Electrode operating temperature
Item
float
C0039476 (UMLS CUI [1,1])
C0347984 (UMLS CUI [1,2])
C0242485 (UMLS CUI [1,3])
X - Time of sensor application
Item
datetime
C0011008 (UMLS CUI [1,1])
C0185125 (UMLS CUI [1,2])
X - ptcO2
Item
float
C0033990 (UMLS CUI [1])
X - ptcCO2
Item
float
C0391839 (UMLS CUI [1,1])
C0694643 (UMLS CUI [1,2])
spOC
Item
spOC
float
C0034108 (UMLS CUI [1,1])
C1291013 (UMLS CUI [1,2])
spCO
Item
spCO
text
C0034108 (UMLS CUI [1,1])
C0007061 (UMLS CUI [1,2])
spMet
Item
spMet
text
C0034108 (UMLS CUI [1,1])
C0025635 (UMLS CUI [1,2])
Waveform
Item
Осциллограмма
text
C0034108 (UMLS CUI [1,1])
C1262059 (UMLS CUI [1,2])
Interpretation
Item
text
C4086187 (UMLS CUI [1])
Extension
Item
text
C0231448 (UMLS CUI [1])

Gebruik dit formulier voor feedback, vragen en verbeteringsvoorstellen.

Velden gemarkeerd met een * zijn verplicht.

Do you need help on how to use the search function? Please watch the corresponding tutorial video for more details and learn how to use the search function most efficiently.

Watch Tutorial