ID

29626

Beskrivning

http://openehr.org/ckm/ Use to record the results of audiology speech tests carried out to assess speech discrimination and speech recognition. Use to record the clinical interpretation of audiology speech tests carried out to assess speech discrimination and speech recognition.

Länk

http://openehr.org/ckm/

Nyckelord

  1. 2018-04-10 2018-04-10 - Halim Ugurlu
Rättsinnehavare

openEHR Foundation

Uppladdad den

10 april 2018

DOI

För en begäran logga in.

Licens

Creative Commons BY-NC 3.0

Modellkommentarer :

Här kan du kommentera modellen. Med hjälp av pratbubblor i Item-grupperna och Item kan du lägga in specifika kommentarer.

Itemgroup-kommentar för :

Item-kommentar för :

Du måste vara inloggad för att kunna ladda ner formulär. Var vänlig logga in eller registrera dig utan kostnad.

openEHR-EHR-OBSERVATION.audiology_speech_test_result.v1

openEHR-EHR-OBSERVATION.audiology_speech_test_result.v1

  1. StudyEvent: openEHR-EHR-OBSERVATION.audiology_speech_test_result.v1
    1. openEHR-EHR-OBSERVATION.audiology_speech_test_result.v1
openEHR-EHR-OBSERVATION.audiology_speech_test_result.v1.xml
Beskrivning

openEHR-EHR-OBSERVATION.audiology_speech_test_result.v1.xml

Audiology Speech Test Result
Beskrivning

Record of results from an audiology speech test conducted for the purpose of assessing speech discrimination and speech recognition, and their clinical interpretation.

Datatyp

text

Alias
UMLS CUI [1,1]
C0004285
UMLS CUI [1,2]
C0037817
UMLS CUI [1,3]
C0456984
Event Series
Beskrivning

Event Series

Datatyp

text

Alias
UMLS CUI [1]
C0441471
Any event
Beskrivning

Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time.

Datatyp

text

Alias
UMLS CUI [1]
C0441471
Test Result Name
Beskrivning

Identification of the audiology speech test performed.

Datatyp

text

Alias
UMLS CUI [1,1]
C1274040
UMLS CUI [1,2]
C0027365
Result Details
Beskrivning

The test measurements and interpretations which can be recorded per ear, or for both ears simultaneously.

Datatyp

text

Alias
UMLS CUI [1,1]
C1522508
UMLS CUI [1,2]
C1274040
Test Ear
Beskrivning

The ear to which to the speech signal is presented.

Datatyp

text

Alias
UMLS CUI [1,1]
C0683443
UMLS CUI [1,2]
C0013443
Performance Intensity Function
Beskrivning

Results obtained for performance intensity function at each test level.

Datatyp

text

Alias
UMLS CUI [1,1]
C0597198
UMLS CUI [1,2]
C0542341
UMLS CUI [1,3]
C0522510
Loudness
Beskrivning

The stimulus intensity.

Datatyp

float

Alias
UMLS CUI [1]
C0178733
Reliability
Beskrivning

Details about the responses correct of the subject being tested.

Datatyp

text

Alias
UMLS CUI [1]
C0035036
Words Correct
Beskrivning

Percentage of words to which the test subject responds correctly.

Datatyp

text

Alias
UMLS CUI [1,1]
C1705313
UMLS CUI [1,2]
C2349182
Elements Correct
Beskrivning

Percentage of elements to which the test subject responds correctly.

Datatyp

text

Alias
UMLS CUI [1,1]
C2349182
UMLS CUI [1,2]
C0013879
Standard Error
Beskrivning

A measure to compare a sample mean and a population mean.

Datatyp

float

Alias
UMLS CUI [1]
C1710181
Adaptive Speech Test
Beskrivning

Details of the adaptive test protocol.

Datatyp

text

Alias
UMLS CUI [1,1]
C0870097
UMLS CUI [1,2]
C0037817
Loudness to Achieve Target
Beskrivning

The mean dB loudness level of the speech stimuli required to achieve the target correct performance.

Datatyp

float

Alias
UMLS CUI [1,1]
C0178733
UMLS CUI [1,2]
C1521840
Signal to Noise Ratio
Beskrivning

The relationship of the loudness of the speech signal in dB to the loudness level of the noise stimulus.

Datatyp

float

Alias
UMLS CUI [1]
C2986823
Clinical Interpretation
Beskrivning

Clinical interpretation of all responses for the identified test ear.

Datatyp

text

Alias
UMLS CUI [1]
C4086187
Overall Interpretation
Beskrivning

Overall clinical interpretation of the responses for both ears.

Datatyp

text

Alias
UMLS CUI [1]
C0459471
Comment
Beskrivning

Additional narrative about the test results and intepretation not captured in other fields.

Datatyp

text

Alias
UMLS CUI [1]
C0947611
Aided Status
Beskrivning

Indication regarding use of an assistive listening device by the test subject during the test.

Datatyp

text

Alias
UMLS CUI [1,1]
C0449438
UMLS CUI [1,2]
C0036605
Type of Listening Device
Beskrivning

Identification of type of assistive listening device used.

Datatyp

text

Alias
UMLS CUI [1]
C0493583
Listening Device Settings
Beskrivning

Narrative description of the details of the assistive listening device settings.

Datatyp

text

Alias
UMLS CUI [1,1]
C0493583
UMLS CUI [1,2]
C1318139
Contralateral Masking
Beskrivning

Contralateral masking signal was presented to the non test ear.

Datatyp

text

Alias
UMLS CUI [1,1]
C0441988
UMLS CUI [1,2]
C0870174
Masking Presentation Method
Beskrivning

The method used to present the constralateral masking test signal.

Datatyp

text

Alias
UMLS CUI [1,1]
C0871511
UMLS CUI [1,2]
C0870174
Masking Stimulus Level
Beskrivning

The level of the contralateral masking speech spectrum noise in dB.

Datatyp

float

Alias
UMLS CUI [1,1]
C0870174
UMLS CUI [1,2]
C2946261
SNR Competing Noise
Beskrivning

Type of signal used as a competing signal during Signal to Noise Ratio testing.

Datatyp

text

Alias
UMLS CUI [1,1]
C2986823
UMLS CUI [1,2]
C0028263
UMLS CUI [1,3]
C0086035
Number of Voices
Beskrivning

Number of voices used to generate multispeaker babble.

Datatyp

integer

Alias
UMLS CUI [1,1]
C0042939
UMLS CUI [1,2]
C0449788
Calibration Reference dB
Beskrivning

Scale used for acoustic calibration check.

Datatyp

text

Alias
UMLS CUI [1]
C0006751
Target Performance Level
Beskrivning

The specified percentage correct used to setup the adaptive test protocol.

Datatyp

text

Alias
UMLS CUI [1,1]
C1521840
UMLS CUI [1,2]
C1518965
Presentation Voice
Beskrivning

The mode by which the speech test stimuli are presented.

Datatyp

text

Alias
UMLS CUI [1,1]
C0449450
UMLS CUI [1,2]
C0042939
Presentation Method
Beskrivning

The method used to present the speech test stimulus.

Datatyp

text

Alias
UMLS CUI [1,1]
C0449450
UMLS CUI [1,2]
C0871511
Response Type
Beskrivning

The type of response the patient is asked to give after hearing each stimulus.

Datatyp

text

Alias
UMLS CUI [1,1]
C1706817
UMLS CUI [1,2]
C0025663
Response Set
Beskrivning

The size of the response set.

Datatyp

text

Alias
UMLS CUI [1]
C0871260
Closed Set Alternatives
Beskrivning

The number of response alternatives offered in the Closed Set.

Datatyp

integer

Alias
UMLS CUI [1,1]
C0871260
UMLS CUI [1,2]
C1523987
Closed Domain Items
Beskrivning

The number of response items offered in the Closed Task Domain.

Datatyp

integer

Alias
UMLS CUI [1,1]
C0587267
UMLS CUI [1,2]
C3540678
UMLS CUI [1,3]
C1883204
Stimulus Type
Beskrivning

The type of speech stimulus used for the speech test.

Datatyp

text

Alias
UMLS CUI [1]
C0449529
Confidence Interval
Beskrivning

A term used in inferential statistics that measures the probability that a population parameter will fall between two set values.

Datatyp

float

Alias
UMLS CUI [1,1]
C1704726
UMLS CUI [1,2]
C1272706
No Test Result
Beskrivning

No test result is available for the test ear.

Datatyp

boolean

Alias
UMLS CUI [1]
C1274040
Reason for No Test Result
Beskrivning

Reason why no result is available for the test ear.

Datatyp

text

Alias
UMLS CUI [1,1]
C0566251
UMLS CUI [1,2]
C3841220
Sample Size
Beskrivning

The number of reverals in an adaptive threshold test used for calculating estimates of a given test result.

Datatyp

integer

Alias
UMLS CUI [1]
C0242618
Listening Device
Beskrivning

Details about the specific assistive listening device used during the test.

Datatyp

text

Alias
UMLS CUI [1]
C0493583
SNR Competing Noise Presentation
Beskrivning

The type of noise used in a speech test measuring speech perception in noise.

Datatyp

text

Alias
UMLS CUI [1,1]
C0037826
UMLS CUI [1,2]
C0028263
UMLS CUI [1,3]
C0441987
Type of Adaptive Test
Beskrivning

The type of adaptive test used. Typically either in quiet or in noise.

Datatyp

text

Alias
UMLS CUI [1,1]
C0231193
UMLS CUI [1,2]
C0332307
Step Size
Beskrivning

The number of dB by which the stimullus intensity is changed after each response.

Datatyp

float

Alias
UMLS CUI [1,1]
C0439497
UMLS CUI [1,2]
C0237686
UMLS CUI [1,3]
C0392747
Start Level
Beskrivning

The initial presentation level in dB.

Datatyp

float

Alias
UMLS CUI [1,1]
C0449976
UMLS CUI [1,2]
C0439497
SNR Speech Presentation Level
Beskrivning

The initial signal to noise ratio level in dB. For example, +20 dB.

Datatyp

float

Alias
UMLS CUI [1,1]
C2986823
UMLS CUI [1,2]
C0037817
UMLS CUI [1,3]
C0449450
Presentation Method
Beskrivning

The method used to present the speech test stimulus.

Datatyp

text

Alias
UMLS CUI [1,1]
C0449450
UMLS CUI [1,2]
C0871511

Similar models

openEHR-EHR-OBSERVATION.audiology_speech_test_result.v1

  1. StudyEvent: openEHR-EHR-OBSERVATION.audiology_speech_test_result.v1
    1. openEHR-EHR-OBSERVATION.audiology_speech_test_result.v1
Name
Typ
Description | Question | Decode (Coded Value)
Datatyp
Alias
Audiology Speech Test Result
Item
Audiology Speech Test Result
text
C0004285 (UMLS CUI [1,1])
C0037817 (UMLS CUI [1,2])
C0456984 (UMLS CUI [1,3])
Event Series
Item
Event Series
text
C0441471 (UMLS CUI [1])
Any event
Item
Any event
text
C0441471 (UMLS CUI [1])
Test Result Name
Item
Test Result Name
text
C1274040 (UMLS CUI [1,1])
C0027365 (UMLS CUI [1,2])
Result Details
Item
Result Details
text
C1522508 (UMLS CUI [1,1])
C1274040 (UMLS CUI [1,2])
Item
Test Ear
text
C0683443 (UMLS CUI [1,1])
C0013443 (UMLS CUI [1,2])
Code List
Test Ear
CL Item
Left Ear (1)
CL Item
Right Ear (2)
CL Item
Binaural (3)
Performance Intensity Function
Item
Performance Intensity Function
text
C0597198 (UMLS CUI [1,1])
C0542341 (UMLS CUI [1,2])
C0522510 (UMLS CUI [1,3])
Loudness
Item
Loudness
float
C0178733 (UMLS CUI [1])
Reliability
Item
Reliability
text
C0035036 (UMLS CUI [1])
Words Correct
Item
Words Correct
text
C1705313 (UMLS CUI [1,1])
C2349182 (UMLS CUI [1,2])
Elements Correct
Item
Elements Correct
text
C2349182 (UMLS CUI [1,1])
C0013879 (UMLS CUI [1,2])
Standard Error
Item
Standard Error
float
C1710181 (UMLS CUI [1])
Adaptive Speech Test
Item
Adaptive Speech Test
text
C0870097 (UMLS CUI [1,1])
C0037817 (UMLS CUI [1,2])
Loudness to Achieve Target
Item
Loudness to Achieve Target
float
C0178733 (UMLS CUI [1,1])
C1521840 (UMLS CUI [1,2])
Signal to Noise Ratio
Item
Signal to Noise Ratio
float
C2986823 (UMLS CUI [1])
Clinical Interpretation
Item
Clinical Interpretation
text
C4086187 (UMLS CUI [1])
Overall Interpretation
Item
Overall Interpretation
text
C0459471 (UMLS CUI [1])
Comment
Item
Comment
text
C0947611 (UMLS CUI [1])
Item
Aided Status
text
C0449438 (UMLS CUI [1,1])
C0036605 (UMLS CUI [1,2])
Code List
Aided Status
CL Item
Aided (1)
CL Item
Unaided (2)
Item
Type of Listening Device
text
C0493583 (UMLS CUI [1])
Code List
Type of Listening Device
CL Item
Hearing Aid (1)
CL Item
Cochlear Implant (2)
CL Item
Bone Conductor Aid (3)
Listening Device Settings
Item
Listening Device Settings
text
C0493583 (UMLS CUI [1,1])
C1318139 (UMLS CUI [1,2])
Item
Contralateral Masking
text
C0441988 (UMLS CUI [1,1])
C0870174 (UMLS CUI [1,2])
Code List
Contralateral Masking
CL Item
Present (1)
CL Item
Absent (2)
Item
Masking Presentation Method
text
C0871511 (UMLS CUI [1,1])
C0870174 (UMLS CUI [1,2])
Code List
Masking Presentation Method
CL Item
Earphone (1)
CL Item
Loudspeaker (2)
Masking Stimulus Level
Item
Masking Stimulus Level
float
C0870174 (UMLS CUI [1,1])
C2946261 (UMLS CUI [1,2])
Item
SNR Competing Noise
text
C2986823 (UMLS CUI [1,1])
C0028263 (UMLS CUI [1,2])
C0086035 (UMLS CUI [1,3])
Code List
SNR Competing Noise
CL Item
White Noise (1)
CL Item
Speech Spectrum Noise (2)
CL Item
Multitalker Babble (3)
CL Item
Alternate Speaker (4)
Number of Voices
Item
Number of Voices
integer
C0042939 (UMLS CUI [1,1])
C0449788 (UMLS CUI [1,2])
Item
Calibration Reference dB
text
C0006751 (UMLS CUI [1])
Code List
Calibration Reference dB
CL Item
dB SPL (1)
CL Item
dB HL (2)
CL Item
dB A (3)
Target Performance Level
Item
Target Performance Level
text
C1521840 (UMLS CUI [1,1])
C1518965 (UMLS CUI [1,2])
Item
Presentation Voice
text
C0449450 (UMLS CUI [1,1])
C0042939 (UMLS CUI [1,2])
Code List
Presentation Voice
CL Item
Live Voice (1)
CL Item
Recorded Voice (2)
Item
Presentation Method
text
C0449450 (UMLS CUI [1,1])
C0871511 (UMLS CUI [1,2])
Code List
Presentation Method
CL Item
Soundfield (1)
CL Item
Insert Earphone (2)
CL Item
Headphone (3)
Item
Response Type
text
C1706817 (UMLS CUI [1,1])
C0025663 (UMLS CUI [1,2])
Code List
Response Type
CL Item
Vocal (1)
CL Item
Picture pointing (2)
CL Item
Written response alternatives (3)
CL Item
Concrete object pointing (4)
Item
Response Set
text
C0871260 (UMLS CUI [1])
Code List
Response Set
CL Item
Open Set (1)
CL Item
Closed Set (2)
CL Item
Closed Task Domain (3)
Closed Set Alternatives
Item
Closed Set Alternatives
integer
C0871260 (UMLS CUI [1,1])
C1523987 (UMLS CUI [1,2])
Closed Domain Items
Item
Closed Domain Items
integer
C0587267 (UMLS CUI [1,1])
C3540678 (UMLS CUI [1,2])
C1883204 (UMLS CUI [1,3])
Item
Stimulus Type
text
C0449529 (UMLS CUI [1])
Code List
Stimulus Type
CL Item
Nonsense syllable (1)
CL Item
Nonsense CVC (2)
CL Item
Nonsense Word (3)
CL Item
Monosyllabic Word (4)
CL Item
Spondee Word (5)
CL Item
Trochee Word (6)
CL Item
Sentence (7)
Confidence Interval
Item
Confidence Interval
float
C1704726 (UMLS CUI [1,1])
C1272706 (UMLS CUI [1,2])
No Test Result
Item
No Test Result
boolean
C1274040 (UMLS CUI [1])
Reason for No Test Result
Item
Reason for No Test Result
text
C0566251 (UMLS CUI [1,1])
C3841220 (UMLS CUI [1,2])
Sample Size
Item
Sample Size
integer
C0242618 (UMLS CUI [1])
Listening Device
Item
Listening Device
text
C0493583 (UMLS CUI [1])
Item
SNR Competing Noise Presentation
text
C0037826 (UMLS CUI [1,1])
C0028263 (UMLS CUI [1,2])
C0441987 (UMLS CUI [1,3])
Code List
SNR Competing Noise Presentation
CL Item
Ipsilateral (1)
CL Item
Contralateral (2)
Item
Type of Adaptive Test
text
C0231193 (UMLS CUI [1,1])
C0332307 (UMLS CUI [1,2])
Code List
Type of Adaptive Test
CL Item
Quiet (1)
CL Item
Signal to Noise Ratio (2)
Step Size
Item
Step Size
float
C0439497 (UMLS CUI [1,1])
C0237686 (UMLS CUI [1,2])
C0392747 (UMLS CUI [1,3])
Start Level
Item
Start Level
float
C0449976 (UMLS CUI [1,1])
C0439497 (UMLS CUI [1,2])
SNR Speech Presentation Level
Item
SNR Speech Presentation Level
float
C2986823 (UMLS CUI [1,1])
C0037817 (UMLS CUI [1,2])
C0449450 (UMLS CUI [1,3])
Item
Presentation Method
text
C0449450 (UMLS CUI [1,1])
C0871511 (UMLS CUI [1,2])
Code List
Presentation Method
CL Item
Auditory Test (1)
CL Item
Audiovisual Test (2)
CL Item
Visual Test (3)

Använd detta formulär för feedback, frågor och förslag på förbättringar.