ID

27012

Description

IOS: impulse oscillometry form of SHIP Study (Study of Health in Pomerania), conducted by the University of Greifswald. SHIP unique domain name SHIP.SHIPTrend0.IMB.BPG.IOS. ODM derived from https://www.fvcm.med.uni-greifswald.de/dd_service/data_use_explore.php. Further information: http://www2.medizin.uni-greifswald.de/cm/fv/ship.html.
 Publication granted by Prof. Völzke. Reference: Völzke H, et al. Cohort profile: the study of health in Pomerania. Int J Epidemiol. 2011;40(2):294-307. PMID: 20167617

Link

https://www.fvcm.med.uni-greifswald.de/dd_service/data_use_explore.php

Keywords

  1. 10/29/17 10/29/17 -
  2. 11/28/17 11/28/17 -
Copyright Holder

University of Greifswald

Uploaded on

October 29, 2017

DOI

To request one please log in.

License

Creative Commons BY-NC 3.0

Model comments :

You can comment on the data model here. Via the speech bubbles at the itemgroups and items you can add comments to those specificially.

Itemgroup comments for :

Item comments for :

In order to download data models you must be logged in. Please log in or register for free.

clinic internal medicine B SHIP-Trend-0 IOS: impulse oscillometry

clinic internal medicine B SHIP-Trend-0 IOS: Impulsoszillometrie

  1. StudyEvent: clinic internal medicine B SHIP-Trend-0 IOS: Impulsoszillometrie
    1. clinic internal medicine B SHIP-Trend-0 IOS: Impulsoszillometrie
IOS: Impulsoszillometrie
Description

IOS: Impulsoszillometrie

Tidal- oder Atemzugvolumen
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_vt

Data type

float

Measurement units
  • L
L
Respiratorische Impedance bei 5 Hz als primäre Messgröße aus der R5 und X5 extrahiert werden
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_z5hz

Data type

float

Measurement units
  • kPa/(L/s)
kPa/(L/s)
Struktur- bzw. Modellparameter des zentralen Atmungswiderstandes
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_rc

Data type

float

Struktur- bzw. Modellparameter der peripheren Atmungswiderstandes
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_rp

Data type

float

Resonanzfrequenz des Reactance-Spektrums, Nulldurchgang des spektralen Reactance-Verlaufes
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_fres

Data type

float

Totale respiratorische Resistance bei 5 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r5hz

Data type

float

Lungenreactance bei 5 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x5hz

Data type

float

Respiratorische Resistance (Rrs) bei 10 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r10hz

Data type

float

Respiratorische Reactance (Xrs) bei 10 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x10hz

Data type

float

Respiratorische Resistance (Rrs) bei 15 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r15hz

Data type

float

Respiratorische Reactance (Xrs) bei 15 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x15hz

Data type

float

Respiratorische Resistance (Rrs) bei 20 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r20hz

Data type

float

Respiratorische Reactance (Xrs) bei 20 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x20hz

Data type

float

Respiratorische Resistance (Rrs) bei 25 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r25hz

Data type

float

Respiratorische Reactance (Xrs) bei 25 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x25hz

Data type

float

Respiratorische Resistance (Rrs) bei 30 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r30hz

Data type

float

Respiratorische Reactance (Xrs) bei 30 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x30hz

Data type

float

Respiratorische Resistance (Rrs) bei 35 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r35hz

Data type

float

Respiratorische Reactance (Xrs) bei 35 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x35hz

Data type

float

Struktur-bzw. Modellparameter respiratorische Elastance
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_ers

Data type

float

Measurement units
  • kPa/L
kPa/L
Flächenindex
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_ax

Data type

float

Measurement units
  • kPa/L
kPa/L
Atmungsfrequenz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_bf

Data type

float

Frequenzabhängigkeit des Rrs-Spektrums zwischen 5 und 20 Hz in %
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_dr5r20

Data type

float

Frequenzabhängigkeit des Rrs-Spektrums zwischen 5 und 20 Hz als Mittelwert
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_mr5r20

Data type

float

Differenz der Resistance zwischen 5 und 20 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_di5_20

Data type

float

Frequenzabhängigkeit des Rrs-Spektrums zwischen 5 und 15 Hz in %
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_d5_15p

Data type

float

Frequenzabhängigkeit des Rrs-Spektrums zwischen 5 und 15 Hz als Mittelwert
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_mr5_15

Data type

float

Differenz der Resistance zwischen 5 und 15 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_di5_15

Data type

float

Coherence, d. h. Linearität zwischen Impulsdruck und Impulsströmung bei 5 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_co5hz

Data type

float

Coherence, d. h. Linearität zwischen Impulsdruck und Impulsströmung bei 20 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_co20hz

Data type

float

Differenz der Mittelwerte aller exspiratorischen und inspiratorischen Reactancesamples bei 5 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_dx5

Data type

float

Differenz der Peakwerte aller exspiratorischen und inspiratorischen Reactance-Atmungsexkursionen bei 5 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_ptpx5

Data type

float

Graduierung der Obstruktion
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_dstage

Data type

float

Respiratorische Conductance bei 5 Hz
Description

SHIP.SHIPTrend0.IMB.BPG.IOS.ios_g5

Data type

float

Measurement units
  • (l/s)/kPa
(l/s)/kPa

Similar models

clinic internal medicine B SHIP-Trend-0 IOS: Impulsoszillometrie

  1. StudyEvent: clinic internal medicine B SHIP-Trend-0 IOS: Impulsoszillometrie
    1. clinic internal medicine B SHIP-Trend-0 IOS: Impulsoszillometrie
Name
Type
Description | Question | Decode (Coded Value)
Data type
Alias
Item Group
IOS: Impulsoszillometrie
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_vt
Item
Tidal- oder Atemzugvolumen
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_z5hz
Item
Respiratorische Impedance bei 5 Hz als primäre Messgröße aus der R5 und X5 extrahiert werden
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_rc
Item
Struktur- bzw. Modellparameter des zentralen Atmungswiderstandes
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_rp
Item
Struktur- bzw. Modellparameter der peripheren Atmungswiderstandes
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_fres
Item
Resonanzfrequenz des Reactance-Spektrums, Nulldurchgang des spektralen Reactance-Verlaufes
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r5hz
Item
Totale respiratorische Resistance bei 5 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x5hz
Item
Lungenreactance bei 5 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r10hz
Item
Respiratorische Resistance (Rrs) bei 10 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x10hz
Item
Respiratorische Reactance (Xrs) bei 10 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r15hz
Item
Respiratorische Resistance (Rrs) bei 15 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x15hz
Item
Respiratorische Reactance (Xrs) bei 15 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r20hz
Item
Respiratorische Resistance (Rrs) bei 20 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x20hz
Item
Respiratorische Reactance (Xrs) bei 20 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r25hz
Item
Respiratorische Resistance (Rrs) bei 25 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x25hz
Item
Respiratorische Reactance (Xrs) bei 25 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r30hz
Item
Respiratorische Resistance (Rrs) bei 30 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x30hz
Item
Respiratorische Reactance (Xrs) bei 30 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_r35hz
Item
Respiratorische Resistance (Rrs) bei 35 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_x35hz
Item
Respiratorische Reactance (Xrs) bei 35 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_ers
Item
Struktur-bzw. Modellparameter respiratorische Elastance
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_ax
Item
Flächenindex
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_bf
Item
Atmungsfrequenz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_dr5r20
Item
Frequenzabhängigkeit des Rrs-Spektrums zwischen 5 und 20 Hz in %
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_mr5r20
Item
Frequenzabhängigkeit des Rrs-Spektrums zwischen 5 und 20 Hz als Mittelwert
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_di5_20
Item
Differenz der Resistance zwischen 5 und 20 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_d5_15p
Item
Frequenzabhängigkeit des Rrs-Spektrums zwischen 5 und 15 Hz in %
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_mr5_15
Item
Frequenzabhängigkeit des Rrs-Spektrums zwischen 5 und 15 Hz als Mittelwert
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_di5_15
Item
Differenz der Resistance zwischen 5 und 15 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_co5hz
Item
Coherence, d. h. Linearität zwischen Impulsdruck und Impulsströmung bei 5 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_co20hz
Item
Coherence, d. h. Linearität zwischen Impulsdruck und Impulsströmung bei 20 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_dx5
Item
Differenz der Mittelwerte aller exspiratorischen und inspiratorischen Reactancesamples bei 5 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_ptpx5
Item
Differenz der Peakwerte aller exspiratorischen und inspiratorischen Reactance-Atmungsexkursionen bei 5 Hz
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_dstage
Item
Graduierung der Obstruktion
float
SHIP.SHIPTrend0.IMB.BPG.IOS.ios_g5
Item
Respiratorische Conductance bei 5 Hz
float

Please use this form for feedback, questions and suggestions for improvements.

Fields marked with * are required.

Do you need help on how to use the search function? Please watch the corresponding tutorial video for more details and learn how to use the search function most efficiently.

Watch Tutorial