Exclusion Criteria
Any evidence of proliferative retinopathy (including PDR or other ischemic retinopathies involving vitreoretinal vascular proliferation) or exudative AMD or retinal vein occlusion in the study eye
boolean
Subjects with any vitreous hemorrhage or any other vitreous opacification which precludes either of the following: visualization of the posterior pole by visual inspection OR adequate assessment of the macula by either OCT and/or fluorescein angiogram in the study eye
boolean
Subjects with macular hole diameter > 400 µm in the study eye
boolean
Aphakia in the study eye
boolean
High myopia (> 8D) in study eye (unless prior cataract extraction or refractive surgery that makes refraction assessment unreliable for myopia severity approximation, in which case axial length >28 mm is an exclusion).