Description

Derived from www.openehr.org . Use to record details about fluids ingested and/or administered. This archetype is intended to be used to mirror current clinical practice with fluid input recorded in orders and in fluid balance charts. In a clinical system business rules can support automation of orders involving fluid input using this archetype to prevent the need for clinicians to duplicate data entry. This archetype will also be the basis for all monitored fluid intake, including ordered fluids and ad hoc consumption. This archetype will used to record details about: - each single fluid ingested or administered, for example each individual cup of tea or glass of water; or - the total fluid input of a fluid over a specified period of time, for example the total amount of 0.9% NaCl administered over an 8 hour nursing shift. Each fluid measurement should be recorded using a separate instance of this archetype. The details recorded using this fluid input archetype may inform fluid balance calculations. A fluid balance chart will typically require a combination of multiple instances of this archetype and multiple instances of OBSERVATION.fluid_output archetype to capture all of the various inputs and outputs, plus a single instance of the OBSERVATION.fluid_balance to record the overall fluid status.

Lien

www.openehr.org

Mots-clés

  1. 09/07/2017 09/07/2017 - Martin Dugas
  2. 09/07/2017 09/07/2017 - Martin Dugas
Téléchargé le

9 juillet 2017

DOI

Pour une demande vous connecter.

Licence

Creative Commons BY-SA 3.0

Modèle Commentaires :

Ici, vous pouvez faire des commentaires sur le modèle. À partir des bulles de texte, vous pouvez laisser des commentaires spécifiques sur les groupes Item et les Item.

Groupe Item commentaires pour :

Item commentaires pour :

Vous devez être connecté pour pouvoir télécharger des formulaires. Veuillez vous connecter ou s’inscrire gratuitement.

Fluid Input (EHR Archetype)

openEHR-EHR-OBSERVATION.fluid_input.v1

  1. StudyEvent: openEHR-EHR-OBSERVATION.fluid_input.v1
    1. openEHR-EHR-OBSERVATION.fluid_input.v1
openEHR-EHR-OBSERVATION.fluid_input.v1.xml
Description

openEHR-EHR-OBSERVATION.fluid_input.v1.xml

Fluid input
Description

The amount of fluid ingested or administered to the individual.

Type de données

float

Alias
UMLS CUI [1]
C0429646
Any event
Description

Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time.

Type de données

text

Alias
UMLS CUI [1]
C0441471
Measurement device
Description

The device used to measure the volume of fluid.

Type de données

text

Alias
UMLS CUI [1]
C2825498
Method
Description

The approach used to quantify the volume of fluid.

Type de données

text

Alias
UMLS CUI [1]
C0871511
Comment
Description

Additional narrative about the fluid input not captured in other fields.

Type de données

text

Alias
UMLS CUI [1]
C0947611
Input device
Description

The device used to administer or deliver the fluid.

Type de données

text

Alias
UMLS CUI [1]
C0699733
Route
Description

The delivery route of the fluid.

Type de données

text

Alias
UMLS CUI [1]
C0449444
Volume
Description

The volume of fluid ingested or administered.

Type de données

float

Alias
UMLS CUI [1]
C0449468
Fluid name
Description

Identification of the fluid ingested or administered.

Type de données

text

Alias
UMLS CUI [1]
C1704353
Fluid details
Description

Additonal details about the fluid.

Type de données

text

Alias
UMLS CUI [1,1]
C1704353
UMLS CUI [1,2]
C1522508
Extension
Description

Additional information required to capture local content or to align with other reference models/formalisms.

Type de données

text

Alias
UMLS CUI [1]
C1546922

Similar models

openEHR-EHR-OBSERVATION.fluid_input.v1

  1. StudyEvent: openEHR-EHR-OBSERVATION.fluid_input.v1
    1. openEHR-EHR-OBSERVATION.fluid_input.v1
Name
Type
Description | Question | Decode (Coded Value)
Type de données
Alias
Fluid input
Item
Fluid input
float
C0429646 (UMLS CUI [1])
Any event
Item
Any event
text
C0441471 (UMLS CUI [1])
Measurement device
Item
Measurement device
text
C2825498 (UMLS CUI [1])
Item
Method
text
C0871511 (UMLS CUI [1])
Code List
Method
CL Item
Estimated (1)
CL Item
Measured (2)
Comment
Item
Comment
text
C0947611 (UMLS CUI [1])
Input device
Item
Input device
text
C0699733 (UMLS CUI [1])
Route
Item
Route
text
C0449444 (UMLS CUI [1])
Volume
Item
Volume
float
C0449468 (UMLS CUI [1])
Fluid name
Item
Fluid name
text
C1704353 (UMLS CUI [1])
Fluid details
Item
Fluid details
text
C1704353 (UMLS CUI [1,1])
C1522508 (UMLS CUI [1,2])
Extension
Item
Extension
text
C1546922 (UMLS CUI [1])

Utilisez ce formulaire pour les retours, les questions et les améliorations suggérées.

Les champs marqués d’un * sont obligatoires.

Do you need help on how to use the search function? Please watch the corresponding tutorial video for more details and learn how to use the search function most efficiently.

Watch Tutorial