ID

14676

Beschrijving

The National Health and Nutrition Examination Survey (NHANES) 2008-2009 audiometry protocol tests the examinee’s hearing threshold (in decibels, dB) at 7 frequencies in a soundproof room. Examinees are asked a series of exclusionary questions, undergo an outer-ear examination (otoscopy), and then have the mobility of their eardrum tested (acoustic immittance). Pure tone signals are then presented to each ear through earphones and the intensity of the signals is varied until the level is identified at which the person is just able to hear the sound. ODM derived from: https://cde.nlm.nih.gov Primary source: https://www.phenxtoolkit.org/ Recent publication: Hendershot, T., Pan, H., Haines, J., Harlan, W.R., Marazita, M.L., McCarty, C.A., Ramos, E.M., and Hamilton, C.M. (2015) Using the PhenX toolkit to add standard measures to a study. Curr. Protoc. Hum. Genet. 86:1.21.1-1.21.17. doi: 10.1002/0471142905.hg0121s86 Permission to publish granted by Carol M. Hamilton.

Link

https://cde.nlm.nih.gov

Trefwoorden

  1. 26-04-16 26-04-16 -
Geüploaded op

26 april 2016

DOI

Voor een aanvraag inloggen.

Licentie

Creative Commons BY-NC 3.0

Model Commentaren :

Hier kunt u commentaar leveren op het model. U kunt de tekstballonnen bij de itemgroepen en items gebruiken om er specifiek commentaar op te geven.

Itemgroep Commentaren voor :

Item Commentaren voor :

U moet ingelogd zijn om formulieren te downloaden. AUB inloggen of schrijf u gratis in.

Audiogram Hearing Test Protocol PhenX Toolkit

Audiogram Hearing Test Protocol PhenX Toolkit

PhenX - audiogram hearing test protocol
Beschrijving

PhenX - audiogram hearing test protocol

Alias
UMLS CUI-1
C3171961
Does the examinee have hearing aids that cannot be removed?
Beschrijving

hearing aids

Datatype

boolean

Alias
UMLS CUI [1]
C0018768
Do you now have a tube in your right or left ear [if Yes, indicate affected ear(s)]?
Beschrijving

ear tubes

Datatype

integer

Alias
UMLS CUI [1]
C0743375
Have you had a cold, sinus problem or earache in the last 24 hours?
Beschrijving

cold sinus problem

Datatype

integer

Alias
UMLS CUI [1]
C0009443
UMLS CUI [2]
C0577887
UMLS CUI [3]
C0013456
(If yes) Which have you had (check all that apply)?
Beschrijving

which have you had

Datatype

integer

Alias
UMLS CUI [1]
C3260392
Have you been exposed to loud noise or listened to music with headphone in the past 24 hours?
Beschrijving

loud noise exposure

Datatype

integer

Alias
UMLS CUI [1]
C3260393
(If Yes) How many hours ago did the noise or music end?
Beschrijving

loud noise when

Datatype

float

Maateenheden
  • h
Alias
UMLS CUI [1]
C3260395
h
Do you hear better in one ear than the other?
Beschrijving

hear better in one ear

Datatype

integer

Alias
UMLS CUI [1]
C3260397
Enter a comment to describe the right ear
Beschrijving

right ear comment

Datatype

text

Alias
UMLS CUI [1,1]
C0229298
UMLS CUI [1,2]
C0678257
Enter a comment to describe the left ear
Beschrijving

left ear comment

Datatype

text

Alias
UMLS CUI [1,1]
C0229299
UMLS CUI [1,2]
C0678257
Right ear acoustic immittance
Beschrijving

acoustic immittance right ear

Datatype

float

Maateenheden
  • daPa
Alias
UMLS CUI [1,1]
C3260403
UMLS CUI [1,2]
C0229298
daPa
Right ear tympanogram ID:
Beschrijving

tympanogram ID right ear

Datatype

text

Alias
UMLS CUI [1]
C3260404
Left ear acoustic Immittance
Beschrijving

acoustic immittance left ear

Datatype

float

Maateenheden
  • daPa
Alias
UMLS CUI [1,1]
C3260403
UMLS CUI [1,2]
C0229299
daPa
Left ear tympanogram ID:
Beschrijving

tympanogram ID left ear

Datatype

text

Alias
UMLS CUI [1]
C3260406
Ear tested first
Beschrijving

ear tested first

Datatype

text

Alias
UMLS CUI [1]
C3260407
Headphones used (original test):
Beschrijving

headphones used original test

Datatype

text

Alias
UMLS CUI [1,1]
C1708331
UMLS CUI [1,2]
C0018786
Right or left ear Ear [PhenX]
Beschrijving

right or left ear

Datatype

integer

Alias
UMLS CUI [1]
C3260416
Test mode right ear
Beschrijving

test mode right ear

Datatype

text

Alias
UMLS CUI [1,1]
C3258221
UMLS CUI [1,2]
C0229298
If mixed, indicate Hz when switched to manual mode (Right Ear)
Beschrijving

hz switched manual right ear

Datatype

integer

Alias
UMLS CUI [1]
C3260412
Frequencies [PhenX]
Beschrijving

frequencies

Datatype

text

Alias
UMLS CUI [1]
C0597494
Threshold [PhenX]
Beschrijving

threshold

Datatype

text

Alias
UMLS CUI [1]
C0449864
Test mode left ear
Beschrijving

test mode left ear

Datatype

text

Alias
UMLS CUI [1,1]
C3258221
UMLS CUI [1,2]
C0229299
If mixed, indicate Hz when switched to manual mode (Left Ear)
Beschrijving

hz switched manual left ear

Datatype

text

Alias
UMLS CUI [1]
C3260418

Similar models

Audiogram Hearing Test Protocol PhenX Toolkit

Name
Type
Description | Question | Decode (Coded Value)
Datatype
Alias
Item Group
PhenX - audiogram hearing test protocol
C3171961 (UMLS CUI-1)
hearing aids
Item
Does the examinee have hearing aids that cannot be removed?
boolean
C0018768 (UMLS CUI [1])
Item
Do you now have a tube in your right or left ear [if Yes, indicate affected ear(s)]?
integer
C0743375 (UMLS CUI [1])
Code List
Do you now have a tube in your right or left ear [if Yes, indicate affected ear(s)]?
CL Item
Yes, right ear  (1)
C3842336 (UMLS CUI-1)
CL Item
Yes, left ear  (2)
C3842335 (UMLS CUI-1)
CL Item
Yes, both ears (3)
C3842334 (UMLS CUI-1)
CL Item
No (4)
C1298908 (UMLS CUI-1)
CL Item
Refused (5)
C1705116 (UMLS CUI-1)
CL Item
Don't know (6)
C3843613 (UMLS CUI-1)
Item
Have you had a cold, sinus problem or earache in the last 24 hours?
integer
C0009443 (UMLS CUI [1])
C0577887 (UMLS CUI [2])
C0013456 (UMLS CUI [3])
Code List
Have you had a cold, sinus problem or earache in the last 24 hours?
CL Item
Yes (1)
C1705108 (UMLS CUI-1)
CL Item
No (2)
C1298908 (UMLS CUI-1)
CL Item
Refused (3)
C1705116 (UMLS CUI-1)
CL Item
Don't know (4)
C3843613 (UMLS CUI-1)
Item
(If yes) Which have you had (check all that apply)?
integer
C3260392 (UMLS CUI [1])
Code List
(If yes) Which have you had (check all that apply)?
CL Item
Cold (1)
C0009443 (UMLS CUI-2)
CL Item
Sinus problem (2)
C0577887 (UMLS CUI-2)
CL Item
Earache, right ear (3)
C0013456 (UMLS CUI-2)
CL Item
Earache, left ear (4)
C0013456 (UMLS CUI-2)
CL Item
Earache, both ears (5)
C0013456 (UMLS CUI-2)
CL Item
Refused (6)
C1705116 (UMLS CUI-1)
CL Item
Don't know (7)
C3843613 (UMLS CUI-1)
Item
Have you been exposed to loud noise or listened to music with headphone in the past 24 hours?
integer
C3260393 (UMLS CUI [1])
Code List
Have you been exposed to loud noise or listened to music with headphone in the past 24 hours?
CL Item
Yes (1)
C1705108 (UMLS CUI-1)
CL Item
No (2)
C1298908 (UMLS CUI-1)
CL Item
Refused (3)
C1705116 (UMLS CUI-1)
CL Item
Don't know (4)
C3843613 (UMLS CUI-1)
loud noise when
Item
(If Yes) How many hours ago did the noise or music end?
float
C3260395 (UMLS CUI [1])
Item
Do you hear better in one ear than the other?
integer
C3260397 (UMLS CUI [1])
Code List
Do you hear better in one ear than the other?
CL Item
Yes, right ear (1)
C3842336 (UMLS CUI-1)
CL Item
Yes, left ear (2)
C3842335 (UMLS CUI-1)
CL Item
No (3)
C1298908 (UMLS CUI-1)
CL Item
Refused (4)
C1705116 (UMLS CUI-1)
CL Item
Don't know (5)
C3843613 (UMLS CUI-1)
Item
Enter a comment to describe the right ear
text
C0229298 (UMLS CUI [1,1])
C0678257 (UMLS CUI [1,2])
Code List
Enter a comment to describe the right ear
CL Item
Normal  (Normal )
CL Item
Excessive cerumen  (Excessive cerumen )
CL Item
Impacted cerumen  (Impacted cerumen )
CL Item
Abnormality, type unknown  (Abnormality, type unknown )
CL Item
Collapsing ear canal (Collapsing ear canal)
Item
Enter a comment to describe the left ear
text
C0229299 (UMLS CUI [1,1])
C0678257 (UMLS CUI [1,2])
Code List
Enter a comment to describe the left ear
CL Item
Normal  (Normal )
CL Item
Excessive cerumen  (Excessive cerumen )
CL Item
Impacted cerumen  (Impacted cerumen )
CL Item
Abnormality, type unknown  (Abnormality, type unknown )
CL Item
Collapsing ear canal (Collapsing ear canal)
acoustic immittance right ear
Item
Right ear acoustic immittance
float
C3260403 (UMLS CUI [1,1])
C0229298 (UMLS CUI [1,2])
tympanogram ID right ear
Item
Right ear tympanogram ID:
text
C3260404 (UMLS CUI [1])
acoustic immittance left ear
Item
Left ear acoustic Immittance
float
C3260403 (UMLS CUI [1,1])
C0229299 (UMLS CUI [1,2])
tympanogram ID left ear
Item
Left ear tympanogram ID:
text
C3260406 (UMLS CUI [1])
Item
Ear tested first
text
C3260407 (UMLS CUI [1])
Code List
Ear tested first
CL Item
Right ear  (Right ear )
CL Item
Left ear (Left ear)
headphones used original test
Item
Headphones used (original test):
text
C1708331 (UMLS CUI [1,1])
C0018786 (UMLS CUI [1,2])
Item
Right or left ear Ear [PhenX]
integer
C3260416 (UMLS CUI [1])
Code List
Right or left ear Ear [PhenX]
CL Item
right (1)
C0205090 (UMLS CUI-1)
CL Item
left (2)
C0205091 (UMLS CUI-1)
Item
Test mode right ear
text
C3258221 (UMLS CUI [1,1])
C0229298 (UMLS CUI [1,2])
Code List
Test mode right ear
CL Item
Automatically  (Automatically )
CL Item
Manually  (Manually )
CL Item
Mixed (Mixed)
Item
If mixed, indicate Hz when switched to manual mode (Right Ear)
integer
C3260412 (UMLS CUI [1])
Code List
If mixed, indicate Hz when switched to manual mode (Right Ear)
CL Item
1000 – First  (1)
CL Item
500  (2)
CL Item
1000 – Second  (3)
CL Item
2000 (4)
CL Item
3000 (5)
CL Item
4000 (6)
CL Item
6000 (7)
CL Item
8000 (8)
Item
Frequencies [PhenX]
text
C0597494 (UMLS CUI [1])
Code List
Frequencies [PhenX]
CL Item
500 Hz (500 Hz)
CL Item
1000 Hz (1000 Hz)
CL Item
2000 Hz  (2000 Hz )
CL Item
3000 Hz (3000 Hz)
CL Item
4000 Hz  (4000 Hz )
CL Item
6000 Hz  (6000 Hz )
CL Item
8000 Hz (8000 Hz)
Item
Threshold [PhenX]
text
C0449864 (UMLS CUI [1])
Code List
Threshold [PhenX]
CL Item
First threshold  (First threshold )
CL Item
Second threshold (Second threshold)
Item
Test mode left ear
text
C3258221 (UMLS CUI [1,1])
C0229299 (UMLS CUI [1,2])
Code List
Test mode left ear
CL Item
Automatically  (Automatically )
CL Item
Manually  (Manually )
CL Item
Mixed (Mixed)
Item
If mixed, indicate Hz when switched to manual mode (Left Ear)
text
C3260418 (UMLS CUI [1])
Code List
If mixed, indicate Hz when switched to manual mode (Left Ear)
CL Item
1000 – First  (1)
CL Item
500  (2)
CL Item
1000 – Second  (3)
CL Item
2000 (4)
CL Item
3000 (5)
CL Item
4000 (6)
CL Item
6000 (7)
CL Item
8000 (8)

Gebruik dit formulier voor feedback, vragen en verbeteringsvoorstellen.

Velden gemarkeerd met een * zijn verplicht.

Do you need help on how to use the search function? Please watch the corresponding tutorial video for more details and learn how to use the search function most efficiently.

Watch Tutorial