Neurologic Examination

Neurologic examination
Description

Neurologic examination

Alias
UMLS CUI-1
C0027853
Timeseries gravitation raw data (left + right hand)
Description

Measured via smartwatch (Apple series >= 4) in all three axes for all assessment steps according to protocol. Sampling rate 100 Hz. Unit measured: Gravitational Force (g) per each 10 milliseconds.

Data type

text

Measurement units
  • g each 10 ms
Alias
UMLS CUI [1,1]
C0018216
UMLS CUI [1,2]
C1511726
g each 10 ms
Timeseries rotation raw data (left + right hand)
Description

Measured via smartwatch (Apple series >= 4) in all three axes. Sampling rate 100 Hz. For all assessment steps according to protocol. Sampling rate 100 Hz. Unit measured: °(degree of rotation) per each 10 milliseconds.

Data type

text

Measurement units
  • g each 10 ms
Alias
UMLS CUI [1,1]
C0035868
UMLS CUI [1,2]
C1511726
g each 10 ms
Timeseries acceleration raw data (left + right hand)
Description

Measured via smartwatch (Apple series >= 4) in all three axes. Sampling rate 100 Hz. Gravitational components are removed. For all assessment steps according to protocol. Sampling rate 100 Hz. Unit measured: Gravitational Force (g) per each 10 milliseconds.

Data type

text

Measurement units
  • g each 10 ms
Alias
UMLS CUI [1,1]
C0000894
UMLS CUI [1,2]
C1511726
g each 10 ms
Timeseries spiral drawing (left + right hand)
Description

Measured via tablet (Apple iPad Pro >= 2018): X,Y points and pencil pressure force. Spirals drawn with both Hands. Sample rate 240 Hz. Force = 1.0 corresponds to average stylus touch: https://developer.apple.com/documentation/uikit/uitouch/1618110-force

Data type

text

Measurement units
  • x, y, force each 4,16 ms
Alias
UMLS CUI [1,1]
C0522554
UMLS CUI [1,2]
C1511726
x, y, force each 4,16 ms
Finger-Tapping: Number of Hits (left + right hand)
Description

Measured on iPad Pro (version >=2018). Number of hits within 15 seconds.

Data type

integer

Alias
UMLS CUI [1,1]
C0870564
UMLS CUI [1,2]
C1511726
Timeseries voice and speach raw data
Description

Measured via iPhone built-in mic (version >= series 7). Sample with 44.1 kHz.

Data type

text

Alias
UMLS CUI [1,1]
C0042939
UMLS CUI [1,2]
C0936012
UMLS CUI [1,3]
C1511726

Similar models

Neurologic Examination

Name
Type
Description | Question | Decode (Coded Value)
Data type
Alias
Item Group
Neurologic examination
C0027853 (UMLS CUI-1)
Gravitation raw data
Item
Timeseries gravitation raw data (left + right hand)
text
C0018216 (UMLS CUI [1,1])
C1511726 (UMLS CUI [1,2])
Rotation raw data
Item
Timeseries rotation raw data (left + right hand)
text
C0035868 (UMLS CUI [1,1])
C1511726 (UMLS CUI [1,2])
Acceleration raw data
Item
Timeseries acceleration raw data (left + right hand)
text
C0000894 (UMLS CUI [1,1])
C1511726 (UMLS CUI [1,2])
Spiral drawing raw data
Item
Timeseries spiral drawing (left + right hand)
text
C0522554 (UMLS CUI [1,1])
C1511726 (UMLS CUI [1,2])
Finger-Tapping
Item
Finger-Tapping: Number of Hits (left + right hand)
integer
C0870564 (UMLS CUI [1,1])
C1511726 (UMLS CUI [1,2])
Voice analysis raw data
Item
Timeseries voice and speach raw data
text
C0042939 (UMLS CUI [1,1])
C0936012 (UMLS CUI [1,2])