openEHR-EHR-OBSERVATION.tympanogram_hf.v1

  1. StudyEvent: openEHR-EHR-OBSERVATION.tympanogram_hf.v1
    1. openEHR-EHR-OBSERVATION.tympanogram_hf.v1
openEHR-EHR-OBSERVATION.tympanogram_hf.v1.xml
Descrição

openEHR-EHR-OBSERVATION.tympanogram_hf.v1.xml

Tympanogram Result - High Frequency
Descrição

Record of measurements of movement at the tympanic membrane in response to a multifrequency probe tone, or a probe tone higher than 226Hz, and changes in air pressure in the ear canal, and their clinical interpretation as an indication of middle ear function.

Tipo de dados

text

Alias
UMLS CUI [1,1]
C0679573
UMLS CUI [1,2]
C1274040
UMLS CUI [1,3]
C0205212
Any event
Descrição

Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time.

Tipo de dados

text

Alias
UMLS CUI [1]
C0441471
Tympanogram Type
Descrição

Classification of the the shape of the tympanogram curve.

Tipo de dados

text

Alias
UMLS CUI [1]
C0679573
Test Ear
Descrição

Identification of the ear being tested.

Tipo de dados

text

Alias
UMLS CUI [1]
C0013443
Result Details
Descrição

The tympanogram test result details, recorded per ear.

Tipo de dados

text

Alias
UMLS CUI [1,1]
C0679573
UMLS CUI [1,2]
C0456984
Peak Pressure
Descrição

Peak pressure (also called tympanometric peak pressure or middle ear pressure or MEP) is the ear canal pressure at which the peak(s) of the tympanogram occurs.

Tipo de dados

float

Alias
UMLS CUI [1]
C0457587
Y Peak
Descrição

Peak compensated static admittance.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0444505
UMLS CUI [1,2]
C0205432
UMLS CUI [1,3]
C1883165
Ear Canal Volume
Descrição

An estimate of the volume of air between the probe tip and the tympanic membrane if the tympanic membrane is intact, or the volume of the ear canal and the middle ear space if the tympanic membrane is perforated. (Fowler and Shanks; 2002, p. 180).

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0013444
UMLS CUI [1,2]
C0449468
Test Result Image
Descrição

Digital representation of the entire result.

Tipo de dados

text

Alias
UMLS CUI [1,1]
C0920316
UMLS CUI [1,2]
C0376478
Comment
Descrição

Additional narrative about the test results and intepretation not captured in other fields.

Tipo de dados

text

Alias
UMLS CUI [1]
C0947611
Measurement Details
Descrição

Measurements derived from the tympanomgram.

Tipo de dados

text

Alias
UMLS CUI [1,1]
C0679573
UMLS CUI [1,2]
C1522508
Tympanometric Width
Descrição

The pressure interval corresponding to a 50% reduction in the peak static admittance.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0487742
UMLS CUI [1,2]
C0085853
Tympanometric Gradient
Descrição

The steepness of the slope of the tympanogram near the peak.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0812409
UMLS CUI [1,2]
C0085853
No Test Result
Descrição

No test result is available for the test ear.

Tipo de dados

boolean

Alias
UMLS CUI [1,1]
C1274040
UMLS CUI [1,2]
C1518422
Reason for No Test Result
Descrição

Reason why no result is available for the test ear.

Tipo de dados

text

Alias
UMLS CUI [1,1]
C0566251
UMLS CUI [1,2]
C3841220
Clinical Interpretation
Descrição

Clinical interpretation of all measurements for the test ear.

Tipo de dados

text

Alias
UMLS CUI [1]
C4086187
Overall Interpretation
Descrição

Overall clinical interpretation of the measurements and related findings using an tympanometer.

Tipo de dados

text

Alias
UMLS CUI [1]
C0459471
Baseline
Descrição

Measurement collection recorded as the basis for comparison with following measurement collections that may included other variables of time or patient state.

Tipo de dados

text

Alias
UMLS CUI [1]
C1442488
Post Valsalva
Descrição

Measurements are recorded after the patient has performed a valsalva manoeuvre.

Tipo de dados

text

Alias
UMLS CUI [1,1]
C0042293
UMLS CUI [1,2]
C0687676
Post Toynbee
Descrição

Measurements are recorded after the patient has performed a toynbee manoeuvre.

Tipo de dados

text

Alias
UMLS CUI [1,1]
C0490843
UMLS CUI [1,2]
C0687676
Rate of Pressure Change
Descrição

The rate of change of pressure used in tympanometry.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C1442094
UMLS CUI [1,2]
C0392747
Multi-frequency
Descrição

Parameters used for multi-frequency tympanometry.

Tipo de dados

text

Alias
UMLS CUI [1,1]
C0439603
UMLS CUI [1,2]
C0439064
UMLS CUI [1,3]
C0085853
Start Pressure
Descrição

The pressure value at which the pressure sweep for tympanometry begins.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0460139
UMLS CUI [1,2]
C0808070
Stop Pressure
Descrição

The pressure value at which the pressure sweep for tympanometry ends. It is a negative pressure if the direction of pressure change is descending and a positive pressure if the direction of pressure change is ascending.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0460139
UMLS CUI [1,2]
C0806020
Tympanometer
Descrição

Details of tympanometer used to conduct the test.

Tipo de dados

text

Alias
UMLS CUI [1,1]
C0085853
UMLS CUI [1,2]
C1522508
Comment
Descrição

Additional narrative about the protocol for the tympanogram not captured in other fields.

Tipo de dados

text

Alias
UMLS CUI [1]
C0947611
Vanhuyse Classification Type
Descrição

Classification of tympanogram type based on Vanhuyse classification system.

Tipo de dados

text

Alias
UMLS CUI [1]
C0679573
Y+200
Descrição

Admittance at +200 daPa.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0001166
UMLS CUI [1,2]
C1883165
Ear Baseline Value
Descrição

Derived ear canal volume.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0013443
UMLS CUI [1,2]
C1442488
Resonant Frequency
Descrição

Frequency at which the total susceptance is zero.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0577554
UMLS CUI [1,2]
C0439603
F45 Degree
Descrição

The frequency corresponding to a 45° phase angle.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0439603
UMLS CUI [1,2]
C0205390
UMLS CUI [1,3]
C0449286
Probe Tone Frequency
Descrição

The frequency of the probe tone played into the ear canal for tympanometry measurement.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0237917
UMLS CUI [1,2]
C0182400
Pressure
Descrição

The fixed pressure in the ear canal.

Tipo de dados

float

Alias
UMLS CUI [1]
C0460139
Sweep Pressure
Descrição

Parameters used for Sweep Pressure high frequency probe tone tympanometry.

Tipo de dados

text

Alias
UMLS CUI [1,1]
C2348625
UMLS CUI [1,2]
C0460139
Start Frequency
Descrição

The frequncy value at which the frequency sweep for tympanometry begins.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0439603
UMLS CUI [1,2]
C0808070
Stop Frequency
Descrição

The frequncy value at which the frequency sweep for tympanometry ends.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0439603
UMLS CUI [1,2]
C0808070
Rate of Frequency Change
Descrição

The rate of change of the probe tone frequency used in tympanometry.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0808070
UMLS CUI [1,2]
C1521828
UMLS CUI [1,3]
C0392747
Y-400
Descrição

Admittance at -400 daPa.

Tipo de dados

float

Alias
UMLS CUI [1,1]
C0001166
UMLS CUI [1,2]
C1883165

Similar models

openEHR-EHR-OBSERVATION.tympanogram_hf.v1

  1. StudyEvent: openEHR-EHR-OBSERVATION.tympanogram_hf.v1
    1. openEHR-EHR-OBSERVATION.tympanogram_hf.v1
Name
Tipo
Description | Question | Decode (Coded Value)
Tipo de dados
Alias
Tympanogram Result - High Frequency
Item
Tympanogram Result - High Frequency
text
C0679573 (UMLS CUI [1,1])
C1274040 (UMLS CUI [1,2])
C0205212 (UMLS CUI [1,3])
Any event
Item
Any event
text
C0441471 (UMLS CUI [1])
Item
Tympanogram Type
text
C0679573 (UMLS CUI [1])
Code List
Tympanogram Type
CL Item
Type 1 (1)
CL Item
Type 2 (2)
CL Item
Type 3 (3)
CL Item
Type 4 (4)
CL Item
Type 4u (5)
CL Item
Indeterminate (6)
Item
Test Ear
text
C0013443 (UMLS CUI [1])
Code List
Test Ear
CL Item
Left Ear (1)
CL Item
Right Ear (2)
Result Details
Item
Result Details
text
C0679573 (UMLS CUI [1,1])
C0456984 (UMLS CUI [1,2])
Peak Pressure
Item
Peak Pressure
float
C0457587 (UMLS CUI [1])
Y Peak
Item
Y Peak
float
C0444505 (UMLS CUI [1,1])
C0205432 (UMLS CUI [1,2])
C1883165 (UMLS CUI [1,3])
Ear Canal Volume
Item
Ear Canal Volume
float
C0013444 (UMLS CUI [1,1])
C0449468 (UMLS CUI [1,2])
Test Result Image
Item
Test Result Image
text
C0920316 (UMLS CUI [1,1])
C0376478 (UMLS CUI [1,2])
Comment
Item
Comment
text
C0947611 (UMLS CUI [1])
Measurement Details
Item
Measurement Details
text
C0679573 (UMLS CUI [1,1])
C1522508 (UMLS CUI [1,2])
Tympanometric Width
Item
Tympanometric Width
float
C0487742 (UMLS CUI [1,1])
C0085853 (UMLS CUI [1,2])
Tympanometric Gradient
Item
Tympanometric Gradient
float
C0812409 (UMLS CUI [1,1])
C0085853 (UMLS CUI [1,2])
No Test Result
Item
No Test Result
boolean
C1274040 (UMLS CUI [1,1])
C1518422 (UMLS CUI [1,2])
Reason for No Test Result
Item
Reason for No Test Result
text
C0566251 (UMLS CUI [1,1])
C3841220 (UMLS CUI [1,2])
Clinical Interpretation
Item
Clinical Interpretation
text
C4086187 (UMLS CUI [1])
Overall Interpretation
Item
Overall Interpretation
text
C0459471 (UMLS CUI [1])
Baseline
Item
Baseline
text
C1442488 (UMLS CUI [1])
Post Valsalva
Item
Post Valsalva
text
C0042293 (UMLS CUI [1,1])
C0687676 (UMLS CUI [1,2])
Post Toynbee
Item
Post Toynbee
text
C0490843 (UMLS CUI [1,1])
C0687676 (UMLS CUI [1,2])
Rate of Pressure Change
Item
Rate of Pressure Change
float
C1442094 (UMLS CUI [1,1])
C0392747 (UMLS CUI [1,2])
Multi-frequency
Item
Multi-frequency
text
C0439603 (UMLS CUI [1,1])
C0439064 (UMLS CUI [1,2])
C0085853 (UMLS CUI [1,3])
Start Pressure
Item
Start Pressure
float
C0460139 (UMLS CUI [1,1])
C0808070 (UMLS CUI [1,2])
Stop Pressure
Item
Stop Pressure
float
C0460139 (UMLS CUI [1,1])
C0806020 (UMLS CUI [1,2])
Tympanometer
Item
Tympanometer
text
C0085853 (UMLS CUI [1,1])
C1522508 (UMLS CUI [1,2])
Comment
Item
Comment
text
C0947611 (UMLS CUI [1])
Item
Vanhuyse Classification Type
text
C0679573 (UMLS CUI [1])
Code List
Vanhuyse Classification Type
CL Item
1B1G (1)
CL Item
3B1G (2)
CL Item
3B3G (3)
CL Item
5B3G (4)
CL Item
Indeterminate (5)
Y+200
Item
Y+200
float
C0001166 (UMLS CUI [1,1])
C1883165 (UMLS CUI [1,2])
Ear Baseline Value
Item
Ear Baseline Value
float
C0013443 (UMLS CUI [1,1])
C1442488 (UMLS CUI [1,2])
Resonant Frequency
Item
Resonant Frequency
float
C0577554 (UMLS CUI [1,1])
C0439603 (UMLS CUI [1,2])
F45 Degree
Item
F45 Degree
float
C0439603 (UMLS CUI [1,1])
C0205390 (UMLS CUI [1,2])
C0449286 (UMLS CUI [1,3])
Probe Tone Frequency
Item
Probe Tone Frequency
float
C0237917 (UMLS CUI [1,1])
C0182400 (UMLS CUI [1,2])
Pressure
Item
Pressure
float
C0460139 (UMLS CUI [1])
Sweep Pressure
Item
Sweep Pressure
text
C2348625 (UMLS CUI [1,1])
C0460139 (UMLS CUI [1,2])
Start Frequency
Item
Start Frequency
float
C0439603 (UMLS CUI [1,1])
C0808070 (UMLS CUI [1,2])
Stop Frequency
Item
Stop Frequency
float
C0439603 (UMLS CUI [1,1])
C0808070 (UMLS CUI [1,2])
Rate of Frequency Change
Item
Rate of Frequency Change
float
C0808070 (UMLS CUI [1,1])
C1521828 (UMLS CUI [1,2])
C0392747 (UMLS CUI [1,3])
Y-400
Item
Y-400
float
C0001166 (UMLS CUI [1,1])
C1883165 (UMLS CUI [1,2])