Eligibility Cardiovascular Disease NCT00631904

Inclusion Criteria
Description

Inclusion Criteria

Alias
UMLS CUI
C1512693
permanent pacemaker or icd implanted for at least 6 weeks
Description

permanent pacemaker | Implantable defibrillator

Data type

boolean

Alias
UMLS CUI [1]
C0281945
UMLS CUI [2]
C0162589
referred for medically indicated mri
Description

Indication Magnetic Resonance Imaging

Data type

boolean

Alias
UMLS CUI [1,1]
C3146298
UMLS CUI [1,2]
C0024485
age greater or equal to 18 years old
Description

Age

Data type

boolean

Alias
UMLS CUI [1]
C0001779
Exclusion Criteria
Description

Exclusion Criteria

Alias
UMLS CUI
C0680251
icd market released before 2001 including gdt ventak-av, gdt mini-ii, gdt mini-iv, gdt mini-iii, gdt prizm-2 mdt gem-i series
Description

Implantable defibrillator

Data type

boolean

Alias
UMLS CUI [1]
C0162589
epicardial coronary sinus lead or subcutaneous array
Description

Epicardial pacing lead Coronary sinus

Data type

boolean

Alias
UMLS CUI [1,1]
C3877971
UMLS CUI [1,2]
C1269893
unable to program all leads to bipolar configuration
Description

Epicardial pacing lead Difficult to Program Medical Device Problem

Data type

boolean

Alias
UMLS CUI [1,1]
C3877971
UMLS CUI [1,2]
C1880319
pacemaker dependent
Description

Artificial cardiac pacemaker Needed

Data type

boolean

Alias
UMLS CUI [1,1]
C0030163
UMLS CUI [1,2]
C0027552
device has reached elective replacement or end of life
Description

Replacement of device elective | Medical Device Cessation

Data type

boolean

Alias
UMLS CUI [1,1]
C1446530
UMLS CUI [1,2]
C0439608
UMLS CUI [2,1]
C0025080
UMLS CUI [2,2]
C1880019
other usual contraindications to mri scanning
Description

Medical contraindication Magnetic Resonance Imaging

Data type

boolean

Alias
UMLS CUI [1,1]
C1301624
UMLS CUI [1,2]
C0024485
the use of inotropic pharmacological agents, such as dobutamine, during the mri
Description

Inotropic agent | Dobutamine

Data type

boolean

Alias
UMLS CUI [1]
C0304509
UMLS CUI [2]
C0012963

Similar models

Eligibility Cardiovascular Disease NCT00631904

Name
Type
Description | Question | Decode (Coded Value)
Data type
Alias
Item Group
C1512693 (UMLS CUI)
permanent pacemaker | Implantable defibrillator
Item
permanent pacemaker or icd implanted for at least 6 weeks
boolean
C0281945 (UMLS CUI [1])
C0162589 (UMLS CUI [2])
Indication Magnetic Resonance Imaging
Item
referred for medically indicated mri
boolean
C3146298 (UMLS CUI [1,1])
C0024485 (UMLS CUI [1,2])
Age
Item
age greater or equal to 18 years old
boolean
C0001779 (UMLS CUI [1])
Item Group
C0680251 (UMLS CUI)
Implantable defibrillator
Item
icd market released before 2001 including gdt ventak-av, gdt mini-ii, gdt mini-iv, gdt mini-iii, gdt prizm-2 mdt gem-i series
boolean
C0162589 (UMLS CUI [1])
Epicardial pacing lead Coronary sinus
Item
epicardial coronary sinus lead or subcutaneous array
boolean
C3877971 (UMLS CUI [1,1])
C1269893 (UMLS CUI [1,2])
Epicardial pacing lead Difficult to Program Medical Device Problem
Item
unable to program all leads to bipolar configuration
boolean
C3877971 (UMLS CUI [1,1])
C1880319 (UMLS CUI [1,2])
Artificial cardiac pacemaker Needed
Item
pacemaker dependent
boolean
C0030163 (UMLS CUI [1,1])
C0027552 (UMLS CUI [1,2])
Replacement of device elective | Medical Device Cessation
Item
device has reached elective replacement or end of life
boolean
C1446530 (UMLS CUI [1,1])
C0439608 (UMLS CUI [1,2])
C0025080 (UMLS CUI [2,1])
C1880019 (UMLS CUI [2,2])
Medical contraindication Magnetic Resonance Imaging
Item
other usual contraindications to mri scanning
boolean
C1301624 (UMLS CUI [1,1])
C0024485 (UMLS CUI [1,2])
Inotropic agent | Dobutamine
Item
the use of inotropic pharmacological agents, such as dobutamine, during the mri
boolean
C0304509 (UMLS CUI [1])
C0012963 (UMLS CUI [2])